Loop-mediated Isothermal Amplification assay (LAMP) based detection of Pasteurella multocida in cases of haemorrhagic septicaemia and fowl cholera

被引:6
|
作者
Bhimani, Mayurkumar P. [1 ]
Bhanderi, Bharat B. [1 ]
Roy, Ashish [1 ]
机构
[1] Anand Agr Univ, Coll Vet Sci & AH, Dept Vet Microbiol, Anand 388001, Gujarat, India
关键词
Fowl cholera; Haemorrhagic septicaemia; Loop-mediated Isothermal amplification (LAMP); Pasteurella multocida; Polymerase Chain; Reaction; RAPID DETECTION;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Twenty two isolates of Pasteurella multocida were obtained from different tissues of dead birds and animals (cattle, buffalo, sheep, and goat) suspected of fowl cholera and haemorrhagic septicaemia. The isolates were confirmed as P. multocida by various biochemical tests and PM PCR. An attempt was made to standardize Loop mediated isothermal amplification (LAMP) using newly designed primer sequences of KMT1 gene. Loop mediated isothermal amplification was conducted using 6 sets of primers at 65 degrees C for 30 minutes and the result was confirmed by visual observation using SYBR green fluorescence dye as marker of positive reaction under UV transilluminator. On electrophoretic analysis of the products on 2% agarose gel, a ladder like pattern was observed, which suggested a positive amplification, whereas no amplification was observed in negative controls. Additionally, product of positive reaction yielded a green fluorescence following addition of SYBR green under UV transilluminator. It was observed that LAMP is a more sensitive test than polymerase chain reaction (PCR), as the former could detect DNA to lower limit of 22.8 pg/mu l, while the latter could detect DNA to lower limit of 2.28 ng/mu l, thus LAMP could detect 100 times lesser concentration of DNA in comparison to PCR. Loop mediated isothermal amplification is a rather newer molecular technique, which can be used for rapid detection of infectious agent at field level and which does not require sophisticated instrument, i.e. thermal cycler. Furthermore, unlike the conventional PCR technique, LAMP requires lesser time to perform and result can be read visually.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [41] Evaluation of a commercial Loop-mediated Isothermal Amplification (LAMP) assay for rapid detection ofPneumocystis jirovecii
    Scharmann, Ulrike
    Kirchhoff, Lisa
    Schmidt, Dirk
    Buer, Jan
    Steinmann, Joerg
    Rath, Peter-Michael
    MYCOSES, 2020, 63 (10) : 1107 - 1114
  • [42] Molecular detection of Coxiella burnetii using an alternative loop-mediated isothermal amplification assay (LAMP)
    Raele, Donato Antonio
    Garofolo, Giuliano
    Galante, Domenico
    Cafiero, Maria Assunta
    VETERINARIA ITALIANA, 2015, 51 (01) : 73 - 78
  • [43] Detection of Mycoplasma wenyonii in cattle and transmission vectors by the loop-mediated isothermal amplification (LAMP) assay
    Qiqi Song
    Lixia Wang
    Rui Fang
    Muhammad Kasib Khan
    Yanqin Zhou
    Junlong Zhao
    Tropical Animal Health and Production, 2012, 45 : 247 - 250
  • [44] Development of Loop-Mediated Isothermal Amplification (LAMP) for Universal Detection of Enteroviruses
    Zhao, Hua-Bing
    Yin, Guang-Ya
    Zhao, Guo-Ping
    Huang, Ai-Hua
    Wang, Jun-Hong
    Yang, Shuang-Feng
    Gao, Hong-Sheng
    Kang, Wei-Jun
    INDIAN JOURNAL OF MICROBIOLOGY, 2014, 54 (01) : 80 - 86
  • [45] Loop-mediated isothermal amplification (LAMP) for the rapid detection of Mycoplasma genitalium
    Edwards, Thomas
    Burke, Patricia
    Smalley, Helen B.
    Gillies, Liz
    Longhurst, Denise
    Vipond, Barry
    Hobbs, Glyn
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 83 (01) : 13 - 17
  • [46] Detection of mink enteritis virus by loop-mediated isothermal amplification (LAMP)
    Wang, Jianke
    Cheng, Shipeng
    Yi, Li
    Cheng, Yuening
    Yang, Shen
    Xu, Hongli
    Li, Zhenguang
    Shi, Xinchuan
    Wu, Hua
    Yan, Xijun
    JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (02) : 401 - 405
  • [47] Development of loop-mediated isothermal amplification (LAMP) for detection of Theileria equi
    Xie, Junren
    Liu, Guangyuan
    Tian, Zhancheng
    Luo, Jin
    ACTA TROPICA, 2013, 127 (03) : 245 - 250
  • [48] DNA detection of Trypanosoma evansi: Diagnostic validity of a new assay based on loop-mediated isothermal amplification (LAMP)
    Tong, Qunbo
    Chen, Rui
    Kong, Qingming
    Goossens, Julie
    Radwanska, Magdalena
    Lou, Di
    Ding, Jianzu
    Zheng, Bin
    Fu, Yixiu
    Wang, Tianping
    Stefan, Magez
    Lu, Shaohong
    VETERINARY PARASITOLOGY, 2018, 250 : 1 - 6
  • [49] Detection of Kudoa amamiensis Using Loop-Mediated Isothermal Amplification (LAMP)
    Sakai, Masahiro
    Biswas, Gouranga
    Kono, Tomoya
    Hikima, Jun-ichi
    Yokoyama, Hiroshi
    FISH PATHOLOGY, 2015, 50 (03): : 119 - 122
  • [50] Detection of toxigenic Clostridium difficile by Loop-Mediated Isothermal Amplification (LAMP)
    Jayaratne, P.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 21 : 379 - 380