Selectivity and sensitivity studies on plasma treated thick film tin oxide gas sensors

被引:37
|
作者
Chaturvedi, A [1 ]
Mishra, VN [1 ]
Dwivedi, R [1 ]
Srivastava, SK [1 ]
机构
[1] Banaras Hindu Univ, Ctr Microelect Res, Dept Elect Engn, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
plasma treatment; tin oxide; stoichiometry;
D O I
10.1016/S0026-2692(99)00147-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with selectivity and sensitivity studies on plasma treated tin oxide thick film gas sensors. Response of oxygen, hydrogen, nitrogen and argon plasma treated sensors has been studied upon exposure to CCl4, C3H7OH, CO, LPG, N2O and CH4. It is observed that the sensitivity of sensors treated in various gaseous plasma is much higher at room temperature in comparison to untreated sensors. The selectivity of these sensors also improves upon plasma treatment, specifically, hydrogen plasma treated sensor becomes sensitive to CO. Also, the XRD characterization of SnO2 has been carried out with respect to various plasma treatments. The structural changes obtained on plasma treatment have been analysed in terms of stoichiometric variations in tin oxide using the ionic conduction model and a thus better explanation for sensitivity of plasma treated sensors have been provided. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
下载
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [31] COPPER-DOPING LEVEL EFFECT ON SENSITIVITY AND SELECTIVITY OF TIN OXIDE THIN-FILM GAS SENSOR
    GALDIKAS, A
    MIRONAS, A
    SETKUS, A
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) : 29 - 32
  • [32] Accurate temperature control of thick film metal oxide gas sensors
    Lowery, P
    Corcoran, P
    Walke, AR
    Loasby, JM
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 649 - 652
  • [33] Tin oxide gas sensors
    Balasubramanian, A
    SOLID STATE PHENOMENA, 1997, 55 : 54 - 58
  • [34] ALGORITHMS TO IMPROVE THE SELECTIVITY OF THERMALLY-CYCLED TIN OXIDE GAS SENSORS
    SEARS, WM
    COLBOW, K
    CONSADORI, F
    SENSORS AND ACTUATORS, 1989, 19 (04): : 333 - 349
  • [35] Thin film tin oxide-based propane gas sensors
    Carbajal-Franco, G
    Tiburcio-Silver, A
    Domínguez, JM
    Sánchez-Juárez, A
    THIN SOLID FILMS, 2000, 373 (1-2) : 141 - 144
  • [36] Platinum and Palladium doped Tin Oxide Thick film sensors for sensing Methane and Hydrogen
    Choudhary, Meenakshi
    Mishra, V. N.
    Dwivedi, R.
    INTERNATIONAL CONFERENCE ON COMMUNICATION AND ELECTRONICS SYSTEM DESIGN, 2013, 8760
  • [37] THICK-FILM GAS SENSORS
    MARTINELLI, G
    CAROTTA, MC
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 23 (2-3) : 157 - 161
  • [38] Oxygen Plasma-Treated Graphene Oxide Surface Functionalization for Sensitivity Enhancement of Thin-Film Piezoelectric Acoustic Gas Sensors
    Zhao, Hongyuan
    Fan, Shuangqing
    Chen, Yan
    Feng, Zhihong
    Zhang, Hao
    Pang, Wei
    Zhang, Daihua
    Zhang, Menglun
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (46) : 40774 - 40781
  • [39] SYNTHESIS AND CHARACTERIZATION OF TIN DIOXIDE POWDERS FOR THE REALIZATION OF THICK-FILM GAS SENSORS
    HONORE, M
    LENAERTS, S
    DESMET, J
    HUYBERECHTS, G
    ROGGEN, J
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 621 - 624
  • [40] Gas Sensitivity Study of Polypyrrole Decorated Graphene Oxide Thick Film
    Patil P.
    Gaikwad G.
    Patil D.R.
    Naik J.
    Journal of The Institution of Engineers (India): Series D, 2016, 97 (1) : 47 - 53