Measurement of U and Pu isotope ratios in hair and nail samples using extraction chromatography and multi-collector inductively coupled plasma mass spectrometry

被引:9
|
作者
Brown, J. N. W. [1 ]
Robertson, J. D. [1 ,2 ]
Brockman, J. D. [2 ]
机构
[1] Univ Missouri, Dept Chem, Columbia, MO 65211 USA
[2] Univ Missouri, Res Reactor, Columbia, MO 65211 USA
基金
美国国家科学基金会;
关键词
Biomonitor; Nuclear forensics; Actinide; Uranium; Plutonium; MC-ICPMS; Extraction chromatography; DRINKING-WATER; ENVIRONMENTAL-SAMPLES; ICP-MS; URANIUM; URINE; PLUTONIUM; SYSTEMATICS; INGESTION;
D O I
10.1016/j.talanta.2014.06.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bioassay capable of monitoring occupational or environmental exposure to special nuclear materials would be a useful tool for nuclear nonproliferation programs. Hair and nail are potential biomonitors of exposure to U and Pu. A method is described to measure isotope ratios of ultra-trace concentrations of U and Pu in hair and nail samples. The method uses multiple extraction chromatography resins to separate U and Pu fractions from the sample matrix. The U recovery was quantitative while the Pu recovery ranged from 81% to 109%, with a U decontamination factor of 5 x 10(4). Following the separation U-234/U-238, U-235/U-238 and Pu-240/Pu-239 were measured in human hair and hair and nail samples using multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS). The human hair and nail samples had elevated ratios of U-234/U-238 which could reflect exposure to naturally fractionated U. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:481 / 485
页数:5
相关论文
共 50 条
  • [21] High Precision Determination of Mercury Isotope Ratios Using Online Mercury Vapor Generation System Coupled with Multi-collector Inductively Coupled Plasma-Mass Spectrometry
    Yin Run-Sheng
    Feng Xin-Bin
    Foucher, Delphine
    Shi Wen-Fang
    Zhao Zhi-Qi
    Wang Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 929 - 934
  • [22] Measurement of U and Pu isotope ratios in hair and nail samples of occupationally exposed workers and controls
    Brown, John W.
    Brockman, John D.
    Robertson, J. David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [23] Separation and Isotopic Measurement of Mg Isotope Ratios in Tooth Samples Using Multiple Collector-Inductively Coupled Plasma-Mass Spectrometry
    Li Zi-Xia
    He Mao-Yong
    Lu Hai
    Ren Tong-Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (05) : 787 - 791
  • [24] Precise Measurement of Tellurium Isotope Ratios in Terrestrial Standards Using a Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Murugan, Rajamanickam
    Aono, Tatsuo
    Sahoo, Sarata Kumar
    MOLECULES, 2020, 25 (08):
  • [25] Hf isotope ratio analysis using multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections
    Chu, NC
    Taylor, RN
    Chavagnac, V
    Nesbitt, RW
    Boella, RM
    Milton, JA
    German, CR
    Bayon, G
    Burton, K
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) : 1567 - 1574
  • [26] Determination of lead isotope ratios in Mn-Fe-rich nodules by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Bao, Zhian
    Zong, Chunlei
    Chen, Lu
    Lei, Danbo
    Chen, Kaiyun
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (12) : 2143 - 2152
  • [27] Enhanced sensitivity in laser ablation multi-collector inductively coupled plasma mass spectrometry
    Cottle, John M.
    Burrows, Andrew J.
    Kylander-Clark, Andrew
    Freedman, Philip A.
    Cohen, Roy S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1700 - 1706
  • [28] Accurate and precise lithium isotopic determinations of igneous rock samples using multi-collector inductively coupled plasma mass spectrometry
    Nishio, Y
    Nakai, S
    ANALYTICA CHIMICA ACTA, 2002, 456 (02) : 271 - 281
  • [29] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [30] Polynomial mass bias functions for the internal standardization of isotope ratio measurements by multi-collector inductively coupled plasma mass spectrometry
    Doherty, William
    Gregoire, D. Conrad
    Bertrand, Nicole
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (03) : 407 - 414