Aptamer-Based Turn-On Detection of Thrombin in Biological Fluids Based on Efficient Phosphorescence Energy Transfer from Mn-Doped ZnS Quantum Dots to Carbon Nanodots

被引:63
|
作者
Zhang, Lu [1 ]
Cui, Peng [1 ]
Zhang, Baocheng [1 ]
Gao, Feng [1 ]
机构
[1] Anhui Normal Univ, Coll Chem & Mat Sci, Anhui Key Lab Chemo Biosensing, LOPAB, Wuhu 241000, Peoples R China
关键词
aptamers; biosensors; quantum dots; phosphorescence; energy transfer; ROOM-TEMPERATURE PHOSPHORESCENCE; GOLD NANOPARTICLES; SEMICONDUCTOR NANOCRYSTALS; FLUORESCENT OLIGONUCLEOTIDES; AMPLIFICATION STRATEGY; MOLECULAR RECOGNITION; SILICA NANOPARTICLES; SENSITIVE DETECTION; OPTICAL-DETECTION; PROTEIN-DETECTION;
D O I
10.1002/chem.201300588
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents the first example of a sensitive, selective, and stable phosphorescent sensor based on phosphorescence energy transfer (PET) for thrombin that functions through thrombin-aptamer recognition events. In this work, an efficient PET donor-acceptor pair using Mn-doped ZnS quantum dots labeled with thrombin-binding aptamers (TBA QDs) as donors, and carbon nanodots (CNDs) as acceptors has been constructed. Due to the - stacking interaction between aptamer and CNDs, the energy donor and acceptor are taken into close proximity, leading to the phosphorescence quenching of donors, TBA QDs. A maximum phosphorescence quenching efficiency as high as 95.9% is acquired. With the introduction of thrombin to the off state of the TBA-QDs-CNDs system, the phosphorescence is turned on due to the formation of quadruplex-thrombin complexes, which releases the energy acceptor CNDs from the energy donors. Based on the restored phosphorescence, an aptamer-based turn-on thrombin biosensor has been demonstrated by using the phosphorescence as a signal transduction method. The sensor displays a linear range of 0-40nM for thrombin, with a detection limit as low as 0.013nM in pure buffers. The proposed aptasensor has also been used to monitor thrombin in complex biological fluids, including serum and plasma, with satisfactory recovery ranging from 96.8 to 104.3%. This is the first time that Mn-doped ZnS quantum dots and CNDs have been employed as a donor-acceptor pair to construct PET-based biosensors, which combines both the photophysical merits of phosphorescence QDs and the superquenching ability of CNDs and thus affords excellent analytical performance. We believe this proposed method could pave the way to a new design of biosensors using PET systems.
引用
收藏
页码:9242 / 9250
页数:9
相关论文
共 50 条
  • [41] A Highly Selective and Sensitive Fluorescent Sensor Based on Molecularly Imprinted Polymer-Functionalized Mn-Doped ZnS Quantum Dots for Detection of Roxarsone in Feeds
    Li, Fei
    Gao, Jie
    Wu, Haocheng
    Li, Yijun
    He, Xiwen
    Chen, Langxing
    NANOMATERIALS, 2022, 12 (17)
  • [42] Room-Temperature Phosphorescent Discrimination of Catechol from Resorcinol and Hydroquinone Based on Sodium Tripolyphosphate Capped Mn-Doped ZnS Quantum Dots
    Wang, He-Fang
    Wu, Ye-Yu
    Yan, Xiu-Ping
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1920 - 1925
  • [43] Fluorescent "turn-on" aptamer sensor for sensitive and reliable detection of Golgi glycoprotein 73 based on nitrogen-doped graphene quantum dots and molybdenum disulfide nanosheets
    Sun, Xinjun
    Fang, Fengyan
    Na, Jintong
    Yan, Runjie
    Huang, Yong
    Zhou, Zhide
    Zhao, Yongxiang
    Li, Guiyin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 225
  • [44] A "turn-on" fluorescence sensor for hydroquinone detection based on BSA doped carbon dots (BSA@CDs) from crawfish shells
    Cheng, Yuliang
    Zhang, Fan
    Zhao, Yajie
    Chen, Jiannan
    Yao, Weirong
    Qian, He
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 325
  • [45] Simultaneous detection of pathogenic bacteria using an aptamer based biosensor and dual fluorescence resonance energy transfer from quantum dots to carbon nanoparticles
    Nuo Duan
    Shijia Wu
    Shaoliang Dai
    Tingting Miao
    Jie Chen
    Zhouping Wang
    Microchimica Acta, 2015, 182 : 917 - 923
  • [46] Simultaneous detection of pathogenic bacteria using an aptamer based biosensor and dual fluorescence resonance energy transfer from quantum dots to carbon nanoparticles
    Duan, Nuo
    Wu, Shijia
    Dai, Shaoliang
    Miao, Tingting
    Chen, Jie
    Wang, Zhouping
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 917 - 923
  • [47] An efficient turn-on fluorescence biosensor for the detection of glutathione based on FRET between N,S dual-doped carbon dots and gold nanoparticles
    Dong, Wenjuan
    Wa, Ruiping
    Gong, Xiaojuan
    Dong, Chuan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (25) : 6687 - 6695
  • [48] An efficient turn-on fluorescence biosensor for the detection of glutathione based on FRET between N,S dual-doped carbon dots and gold nanoparticles
    Wenjuan Dong
    Ruiping Wang
    Xiaojuan Gong
    Chuan Dong
    Analytical and Bioanalytical Chemistry, 2019, 411 : 6687 - 6695
  • [49] Turn-on near-infrared electrochemiluminescence sensing of thrombin based on resonance energy transfer between CdTe/CdS coresmall/shellthick quantum dots and gold nanorods
    Wang, Jing
    Jiang, Xiaochun
    Han, Heyou
    BIOSENSORS & BIOELECTRONICS, 2016, 82 : 26 - 31
  • [50] Aptamer Biosensor Based on Fluorescence Resonance Energy Transfer from Upconverting Phosphors to Carbon Nanoparticles for Thrombin Detection in Human Plasma
    Wang, Yuhui
    Bao, Lei
    Liu, Zhihong
    Pang, Dai-Wen
    ANALYTICAL CHEMISTRY, 2011, 83 (21) : 8130 - 8137