Pulse Transit Time and Blood Pressure During Cardiopulmonary Exercise Tests

被引:60
|
作者
Wibmer, T. [1 ]
Doering, K. [1 ]
Kropf-Sanchen, C. [1 ]
Ruediger, S. [1 ]
Blanta, I. [1 ]
Stoiber, K. M. [1 ]
Rottbauer, W. [1 ]
Schumann, C. [1 ]
机构
[1] Univ Hosp Ulm, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Blood pressure; Cardio-pulmonary exercise test; Pulse transit time; Pulse wave velocity; Cardiovascular reactivity; WAVE VELOCITY; CARDIOVASCULAR CHANGES; VALIDATION;
D O I
10.33549/physiolres.932581
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Pulse transit time (PTT), the interval between ventricular electrical activity and peripheral pulse wave, is assumed to be a surrogate marker for blood pressure (BP) changes. The objective of this study was to analyze PTT and its relation to BP during cardiopulmonary exercise tests (CPET). In 20 patients (mean age 51 +/- 18.4 years), ECG and finger-photoplethysmography were continuously recorded during routine CPETs. PTT was calculated for each R-wave in the ECG and the steepest slope of the corresponding upstroke in the plethysmogram. For each subject, linear and non-linear regression models were used to assess the relation between PTT and upper-arm oscillometric BP in 9 predefined measuring points including measurements at rest, during exercise and during recovery. Mean systolic BP (sBP) and PTT at rest were 128 mm Hg and 366 ms respectively, 197 mm Hg and 289 ms under maximum exercise, and 128 mm Hg and 371 ms during recovery. Linear regression showed a significant, strong negative correlation between PTT and sBP. The correlation between PTT and diastolic BP was rather weak. Bland-Altman plots of sBP values estimated by the regression functions revealed slightly better limits of agreements for the non-linear model (-10.9 to 10.9 mm Hg) than for the linear model (-13.2 to 13.1 mm Hg). These results indicate that PTT is a good potential surrogate measure for sBP during exercise and could easily be implemented in CPET as an additional parameter of cardiovascular reactivity. A non-linear approach might be more effective in estimating BP than linear regression.
引用
收藏
页码:287 / 296
页数:10
相关论文
共 50 条
  • [31] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    [J]. BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [32] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Lee, Joonnyong
    Sohn, JangJay
    Park, Jonghyun
    Yang, SeungMan
    Lee, Saram
    Kim, Hee Chan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [33] Photoplethysmography Derivatives and Pulse Transit Time in Overnight Blood Pressure Monitoring
    Shahrbabaki, Sobhan Salari
    Ahmed, Beena
    Penzel, Thomas
    Cvetkovic, Dean
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2855 - 2858
  • [34] THE RELATIONSHIP BETWEEN PULSE TRANSIT-TIME AND BLOOD-PRESSURE
    MARIE, GV
    LO, CR
    JOHNSTON, DW
    [J]. BIOLOGICAL PSYCHOLOGY, 1980, 11 (3-4) : 298 - 298
  • [35] Noninvasive Continuous Blood Pressure Estimation with Peripheral Pulse Transit Time
    Li, Yibin
    Chen, Xiaomeng
    Zhang, Yang
    Deng, Ning
    [J]. PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 66 - 69
  • [36] Implantable Sensor for Blood Pressure Determination via Pulse Transit Time
    Fiala, Jens
    Bingger, Philipp
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    [J]. 2010 IEEE SENSORS, 2010, : 1226 - 1229
  • [37] Measuring blood pressure by a cuffless device using the pulse transit time
    Patzak, Andreas
    [J]. INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2021, 8
  • [38] PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, MH
    BABBS, CF
    BOURLAND, JD
    TACKER, WA
    [J]. PSYCHOPHYSIOLOGY, 1981, 18 (01) : 71 - 74
  • [39] Comparison of the Correlation of Different Pulse Transit Time Parameters to Blood Pressure
    Lin, Wan-Hua
    Samuel, Oluwarotimi Williams
    Liu, Qing
    Zhang, Yuan-Ting
    Li, Guanglin
    [J]. INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS, 2019, 64 : 169 - 173
  • [40] An implantable optical blood pressure sensor based on pulse transit time
    Jens Fiala
    Philipp Bingger
    Dominic Ruh
    Katharina Foerster
    Claudia Heilmann
    Friedhelm Beyersdorf
    Hans Zappe
    Andreas Seifert
    [J]. Biomedical Microdevices, 2013, 15 : 73 - 81