Adaptive correction of imaging plane position in segmented K-space cine cardiac MRI

被引:18
|
作者
Chuang, ML [1 ]
Chen, MH [1 ]
Khasgiwala, VC [1 ]
McConnell, MV [1 ]
Edelman, RR [1 ]
Manning, WJ [1 ]
机构
[1] BETH ISRAEL HOSP,CHARLES A DANA RES INST,BOSTON,MA 02215
来源
关键词
heart; MR; left ventricular function; navigator echo; myocardium;
D O I
10.1002/jmri.1880070507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variability among breath-holds frequently produces registration errors, a situation that may contribute to reproducibility error in anatomic indices, A navigator-echo-based method for real-time prospective correction of imaging slice level was applied to breath-hold cine cardiac imaging of 13 subjects. Repeat acquisitions with correction in the cardiac short-axis orientation showed significantly improved reproducibility in fractional area change and endocardial centroid location as compared with conventional noncorrected methods.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 50 条
  • [1] Evaluation of k-space segmented cine sequences for fast functional cardiac imaging
    Schulen, V
    Schick, F
    Loichat, J
    Helber, U
    Huppert, PE
    Laub, G
    Claussen, CD
    INVESTIGATIVE RADIOLOGY, 1996, 31 (08) : 512 - 522
  • [2] Segmented k-space and real-time cardiac cine MR imaging with radial trajectories
    Shankaranarayanan, A
    Simonetti, OP
    Laub, G
    Lewin, JS
    Duerk, JL
    RADIOLOGY, 2001, 221 (03) : 827 - 836
  • [3] Retrospective Rigid Motion Correction in k-Space for Segmented Radial MRI
    Vaillant, Ghislain
    Prieto, Claudia
    Kolbitsch, Christoph
    Penney, Graeme
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 1 - 10
  • [4] Segmented k-space fast cardiac imaging using an echo-train readout
    Epstein, FH
    Wolff, SD
    Arai, AE
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (03) : 609 - 613
  • [5] Segmented K-space cine breath-hold cardiovascular MR imaging .1. Principles and technique
    Bluemke, DA
    Boxerman, JL
    Atalar, E
    McVeigh, ER
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) : 395 - 400
  • [6] Cardiac imaging: Comparison of two-shot echo-planar imaging with fast segmented K-space and conventional gradient-echo cine acquisitions
    Leung, DA
    Debatin, JF
    Wildermuth, S
    McKinnon, GC
    vonSchulthess, GK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 684 - 688
  • [7] Multi-echo segmented k-space imaging: An optimized hybrid sequence for ultrafast cardiac imaging
    Reeder, SB
    Atalar, E
    Faranesh, AZ
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (02) : 375 - 385
  • [8] Detection and Correction of Cardiac MRI Motion Artefacts During Reconstruction from k-space
    Oksuz, Ilkay
    Clough, James
    Ruijsink, Bram
    Puyol-Anton, Esther
    Bustin, Aurelien
    Cruz, Gastao
    Prieto, Claudia
    Rueckert, Daniel
    King, Andrew P.
    Schnabel, Julia A.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT IV, 2019, 11767 : 695 - 703
  • [9] Segmented K-space cine breath-hold cardiovascular MR imaging .2. Evaluation of aortic vasculopathy
    Bluemke, DA
    Boxerman, JL
    Mosher, T
    Lima, JAC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) : 401 - 407
  • [10] Retrospective motion correction through multi-average k-space data elimination (REMAKE) for free-breathing cardiac cine imaging
    Neofytou, Alexander Paul
    Neji, Radhouene
    Kowalik, Grzegorz Tomasz
    Mooiweer, Ronald
    Wong, James
    Fotaki, Anastasia
    Ferreira, Joana
    Evans, Carl
    Bosio, Filippo
    Mughal, Nabila
    Razavi, Reza
    Pushparajah, Kuberan
    Roujol, Sebastien