Cardiac imaging: Comparison of two-shot echo-planar imaging with fast segmented K-space and conventional gradient-echo cine acquisitions

被引:6
|
作者
Leung, DA [1 ]
Debatin, JF [1 ]
Wildermuth, S [1 ]
McKinnon, GC [1 ]
vonSchulthess, GK [1 ]
机构
[1] UNIV ZURICH HOSP,DEPT RADIOL,MRI CTR,CH-8091 ZURICH,SWITZERLAND
来源
关键词
MR imaging; echo-planar imaging; segmented K-space heart; rapid imaging;
D O I
10.1002/jmri.1880050611
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the cardiac image quality of multishot echo-planar imaging (EPI), segmented Ii-space, and conventional cine acquisitions. Three techniques were used to obtain gated multiphase acquisitions of an axial section traversing both ventricles in 10 volunteers: two-shot EPI acquired nonsequentially over two heart beats breath-held; segmented Ii-space cine with eight K-space lines acquired per cardiac trigger over 16 R-R intervals, also breath-held; and 24 cine phases obtained over 256 R-R intervals. Intraventricular SNRs with two-shot EPI were superior to segmented Ii-space cine acquisitions (P < .005) and not statistically different from conventional cine acquisitions (P < .1). Intraventricular signal was most homogeneous on conventional cine images (P < .05). Coronary artery visualization and myocardial delineation were better on the EPI image set than on segmented li-space cine images (p < .05). Two-shot EPI provides high-quality gated cardiac images with an acquisition time of only 2 seconds.
引用
收藏
页码:684 / 688
页数:5
相关论文
共 50 条
  • [1] The importance of k-space trajectory on off-resonance artifact in segmented echo-planar imaging
    Bender, Jacob A.
    Ahmad, Rizwan
    Simonetti, Orlando P.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2013, 42 (02) : 23 - 31
  • [2] Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging
    Plein, S
    Bloomer, TN
    Ridgway, JP
    Jones, TR
    Bainbridge, GJ
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 230 - 236
  • [3] Direct comparison of two methods to measure T1:: in vitro and in vivo values by echo-planar imaging and by segmented k-space imaging
    Haselgrove, J
    Hunte, M
    Hurh, P
    Steen, RG
    MAGNETIC RESONANCE IMAGING, 2004, 22 (03) : 291 - 298
  • [4] Diuretic-enhanced gadolinium excretory MR urography:: comparison of conventional gradient-echo sequences and echo-planar imaging
    Nolte-Ernsting, CCA
    Tacke, J
    Adam, GB
    Haage, P
    Jung, P
    Jakse, G
    Günther, RW
    EUROPEAN RADIOLOGY, 2001, 11 (01) : 18 - 27
  • [5] Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging
    C. A. Nolte-Ernsting
    Josef Tacke
    Gerhard B. Adam
    Patrick Haage
    Peter Jung
    Gerhard Jakse
    Rolf W. Günther
    European Radiology, 2001, 11 : 18 - 27
  • [6] Segmented k-space fast cardiac imaging using an echo-train readout
    Epstein, FH
    Wolff, SD
    Arai, AE
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (03) : 609 - 613
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [9] Perfusion-sensitive MR imaging of gliomas: Comparison between gradient-echo and spin-echo echo-planar imaging techniques
    Sugahara, T
    Korogi, Y
    Kochi, M
    Ushio, Y
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (07) : 1306 - 1315
  • [10] Activation of the sensorimotor cortex at 1.O T: Comparison of echo-planar and gradient-echo imaging
    van der Kallen, BFW
    van Erning, LJTO
    van Zuijlen, MWJ
    Merx, H
    Thijssen, HOM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (06) : 1099 - 1104