Niosomes as carriers of radiopaque contrast agents for X-ray imaging

被引:2
|
作者
Muller, D
Foulon, M
Bonnemain, B
Vandamme, TF
机构
[1] Univ Louis Pasteur Strasbourg 1, Fac Pharm, UMR Pharmacol & Physicochim Interact Cellulaires, F-67401 Illkirch Graffenstaden, France
[2] Univ Louis Pasteur Strasbourg 1, Fac Pharm, Lab Pharm Galen & Pharmacotech, F-67401 Illkirch Graffenstaden, France
[3] Labs Guerbet, Pole R&D Galen, F-93600 Aulnay Sous Bois, France
关键词
non-ionic surfactant; drug carriers; niosomes; iobitridol; radiopaque drug delivery;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Non-ionic surfactant vesicles (niosomes) are considered as carriers of iobitridol, a diagnostic agent used for X-ray imaging. The niosomes, with a diameter between 150 and 175 nm, are prepared using the film-hydration method followed by sonication. These vesicles were obtained with appropriate mixtures of D-alpha tocopheryl polyethylene glycol 1000 succinate, polyoxyethylene glycol 4000 stearate, sorbitan monostearate, cholesterol and dicetylphosphate. Methods allowing the increase of the rate of encapsulation and the stability of the vesicles were carried out. In addition to the study of the formulation of the vesicles, the physico-chemical and morphological properties of the vesicles have been studied.
引用
收藏
页码:227 / 243
页数:17
相关论文
共 50 条
  • [41] Radiopaque contrast medium distribution: influence of gravity on x-ray flow measurements
    Clough, Anne
    Haworth, Steven
    Friedman, Jonathan
    Dawson, Christopher
    Hoffman, Eric
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [42] Radiopaque fibrin nanocomplex as a promising tool for X-ray imaging applications
    Vedakumari, Sathyaraj Weslen
    Prabu, Periyathambi
    Jancy, S. Jacqulin Veda
    Pravin, Yovan Raja
    Manickavasagam, Kanagavel
    Sastry, Thotapalli Parvathaleswara
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2022, 200 : 285 - 292
  • [43] Radiopaque iodinated nano-emulsions for preclinical X-ray imaging
    Hallouard, Francois
    Anton, Nicolas
    Zuber, Guy
    Choquet, Philippe
    Li, Xiang
    Arntz, Youri
    Aubertin, Gaelle
    Constantinesco, Andre
    Vandamme, Thierry F.
    RSC ADVANCES, 2011, 1 (05) : 792 - 801
  • [44] Low density contrast agents for x-ray phase contrast imaging: the use of ambient air for x-ray angiography of excised murine liver tissue
    Laperle, Christopher M.
    Hamilton, Theron J.
    Wintermeyer, Philip
    JWalker, Evan
    Shi, Daxin
    Anastasio, Mark A.
    Derdak, Zoltan
    Wands, Jack R.
    Diebold, Gerald
    Rose-Petruck, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23): : 6911 - 6923
  • [45] Coherence-contrast x-ray imaging based on x-ray interferometry
    Yoneyama, A
    Takeda, T
    Tsuchiya, Y
    Wu, J
    Lwin, TT
    Hyodo, K
    APPLIED OPTICS, 2005, 44 (16) : 3258 - 3261
  • [46] Contrast imaging with a monochromatic x-ray scanner
    Pole, Donald J.
    Popovic, Kosta
    Williams, Mark B.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [47] X-ray phase contrast imaging at MAMI
    El-Ghazaly, M.
    Backe, H.
    Lauth, W.
    Kube, G.
    Kunz, P.
    Sharafutdinov, A.
    Weber, T.
    EUROPEAN PHYSICAL JOURNAL A, 2006, 28 (Suppl 1): : 197 - 208
  • [48] X-ray phase contrast imaging at MAMI
    M. El-Ghazaly
    H. Backe
    W. Lauth
    G. Kube
    P. Kunz
    A. Sharafutdinov
    T. Weber
    The European Physical Journal A - Hadrons and Nuclei, 2006, 28 : 197 - 208
  • [49] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [50] Poly(iohexol) Nanoparticles As Contrast Agents for in Vivo X-ray Computed Tomography Imaging
    Yin, Qian
    Yap, Felix Y.
    Yin, Lichen
    Ma, Liang
    Zhou, Qin
    Dobrucki, Lawrence W.
    Fan, Timothy M.
    Gaba, Ron C.
    Cheng, Jianjun
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (37) : 13620 - 13623