Stent-grafting for unfavorable abdominal aortic aneurysm: a practical challenge

被引:3
|
作者
Hu Zuo-jun [1 ]
Chang Guang-qi [1 ]
Li Xiao-xi [1 ]
Huang Xue-ling [1 ]
Yin Heng-hui [1 ]
Wang Shen-ming [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Vasc Surg, Guangzhou 510080, Guangdong, Peoples R China
关键词
aortic aneurysm; abdominal; endovascular repair; stent-graft; concomitant intervention; outcome analysis; ENDOVASCULAR REPAIR; MIGRATION; ACCESS; ARTERY;
D O I
10.3760/cma.j.issn.0366-6999.2009.07.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endovascular treatment of abdominal aortic aneurysm (AAA) has improved greatly in the last 15 years. The present study aimed to evaluate the endografting experience for the treatment of unfavorable abdominal aortic aneurysm (uAAA). Methods During December 2001 and December 2007, 41 patients with uAAA were treated with endografting using concomitant techniques. Patients were followed up for 1 to 48 months (mean 20.5 months). Results Technical success rate was 97.6% (40/41) with 1 failure converted to open surgery for an unaccessed iliac stenosis. Nine (22.5%) type I endoleaks (5 proximal and 4 distal) were observed on the completion angiograms and successfully corrected with aortic cuffs and iliac extensions during the procedure. Twenty-two of the planed adjunctive procedures were concomitantly performed just before endograft-implantation. There were 2 (5.0%) type I endoleaks at 30 days; one type I patient was treated by open conversion, another type I patient died from a rupture before treatment in the ward, causing a 2.5% of initial mortality. The two type II endoleaks were observed without aneurismal expansion. No buttock or leg claudication or ischemic colitis occured. During late follow-up, one additional death occurred from stroke. One new type I endoleak was encountered from thrombocytopenia, which caused a 2.6% secondary endoleak that converted to an open surgery in the third month after a failed transabdominal banding of the aortic neck in the second month. All type II endoleaks had disappeared in the third and sixth month. The Endografts did not present signs of material fatigue and no other type of endoleak formed. One patient presented with left limb ischemia, which underwent percutaneous transluminal angioplasty. There was no additional aneurysm rupture or any endograft imgration. Conclusion The endografting with concomitant procedures is a feasible and efficient alternative for managing unfavorable AAAs, achieving low morbidity and mortality rates and has a good clinical outcome.
引用
收藏
页码:787 / 792
页数:6
相关论文
共 50 条
  • [21] Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies
    Chavan, A
    Pichlmaier, M
    Kirchhoff, T
    Baus, S
    Galanski, M
    RADIOLOGE, 2001, 41 (08): : 681 - +
  • [22] Expanding the indication for stent-grafting in thoracic aortic aneurysms
    Garlicki, Miroslaw
    Nowicki, Miroslaw
    Walecki, Jerzy
    Labus, Krzysztof
    Ehrlich, Marek
    Czub, Pawel
    Gil, Robert
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2006, 3 (01): : 83 - 87
  • [23] How to deal with the left subelavian artery in endovascular stent-grafting for distal aortic arch aneurysm
    Kurimoto, Y
    Asai, Y
    Maeda, T
    Osawa, H
    Hase, M
    Kawaharada, N
    Morishita, K
    CIRCULATION, 2005, 112 (17) : U776 - U776
  • [24] Open stent-grafting for adult patent ductus arteriosus with a distal aortic arch aneurysm.
    Sasaki B.
    Shimizu K.
    Ohno N.
    Tsukuda K.
    Fujiwara K.
    General Thoracic and Cardiovascular Surgery, 2011, 59 (12) : 806 - 808
  • [25] Stent-grafting for traumatic aortic rupture: Pitfalls in sizing
    Zipfel, B.
    Fritschi, S.
    Hammerschmidt, R.
    Buz, S.
    Lehmkuhl, L.
    Hetzer, R.
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 : I34 - I35
  • [26] Abdominal Stent Grafting With Coil Embolization for an Abdominal Aortic Aneurysm Sac With a Short Neck
    Sakamoto, Daisuke
    Sakamoto, Takuya
    Nagayoshi, Yasuhiro
    Takano, Tamaki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [27] Open stent grafting for abdominal aortic aneurysm in a patient with a severely calcified abdominal aorta
    Yamamoto, Hiroshi
    Yamamoto, Fumio
    Ishibashi, Kazuyuki
    Yamaura, Gembu
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (03) : 494 - 496
  • [28] Endovascular stent-grafting for recurrent aneurysm in Behcet's disease
    Watanabe, H
    Oda, H
    Yoshida, TS
    Yamaura, M
    Takahashi, K
    Miida, T
    Takahashi, N
    Nakazawa, S
    Kanazawa, H
    Higuma, N
    Aizawa, Y
    INTERNATIONAL HEART JOURNAL, 2005, 46 (04) : 745 - 749
  • [29] Successful shrinkage of distal arch and proximal descending aortic aneurysm after transaortic endovascular stent-grafting
    Sueda, T
    Orihashi, K
    Okada, K
    Sugawara, Y
    Imai, K
    Hamamoto, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (05) : 716 - 721
  • [30] The renal impact of aortic stent-grafting in patients with a horseshoe kidney
    Jackson, RW
    Fay, DM
    Wyatt, MG
    Rose, JD
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (06) : 632 - 636