Stent-grafting for unfavorable abdominal aortic aneurysm: a practical challenge

被引:3
|
作者
Hu Zuo-jun [1 ]
Chang Guang-qi [1 ]
Li Xiao-xi [1 ]
Huang Xue-ling [1 ]
Yin Heng-hui [1 ]
Wang Shen-ming [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Vasc Surg, Guangzhou 510080, Guangdong, Peoples R China
关键词
aortic aneurysm; abdominal; endovascular repair; stent-graft; concomitant intervention; outcome analysis; ENDOVASCULAR REPAIR; MIGRATION; ACCESS; ARTERY;
D O I
10.3760/cma.j.issn.0366-6999.2009.07.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endovascular treatment of abdominal aortic aneurysm (AAA) has improved greatly in the last 15 years. The present study aimed to evaluate the endografting experience for the treatment of unfavorable abdominal aortic aneurysm (uAAA). Methods During December 2001 and December 2007, 41 patients with uAAA were treated with endografting using concomitant techniques. Patients were followed up for 1 to 48 months (mean 20.5 months). Results Technical success rate was 97.6% (40/41) with 1 failure converted to open surgery for an unaccessed iliac stenosis. Nine (22.5%) type I endoleaks (5 proximal and 4 distal) were observed on the completion angiograms and successfully corrected with aortic cuffs and iliac extensions during the procedure. Twenty-two of the planed adjunctive procedures were concomitantly performed just before endograft-implantation. There were 2 (5.0%) type I endoleaks at 30 days; one type I patient was treated by open conversion, another type I patient died from a rupture before treatment in the ward, causing a 2.5% of initial mortality. The two type II endoleaks were observed without aneurismal expansion. No buttock or leg claudication or ischemic colitis occured. During late follow-up, one additional death occurred from stroke. One new type I endoleak was encountered from thrombocytopenia, which caused a 2.6% secondary endoleak that converted to an open surgery in the third month after a failed transabdominal banding of the aortic neck in the second month. All type II endoleaks had disappeared in the third and sixth month. The Endografts did not present signs of material fatigue and no other type of endoleak formed. One patient presented with left limb ischemia, which underwent percutaneous transluminal angioplasty. There was no additional aneurysm rupture or any endograft imgration. Conclusion The endografting with concomitant procedures is a feasible and efficient alternative for managing unfavorable AAAs, achieving low morbidity and mortality rates and has a good clinical outcome.
引用
收藏
页码:787 / 792
页数:6
相关论文
共 50 条
  • [1] Aortocaval fistula after endovascular stent-grafting of abdominal aortic aneurysm
    Fujisawa, Y.
    Kurimoto, Y.
    Morishita, K.
    Fukada, J.
    Saito, T.
    Ohori, S.
    Abe, T.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2009, 50 (03): : 387 - 389
  • [2] Fenestrated stent-grafting after previous endovascular abdominal aortic aneurysm repair
    Vourliotakis, G.
    Bos, W. T. G. J.
    Beck, A. W.
    Van den Dungen, J. J. A. M.
    Prins, T. R.
    Verhoeven, E. L. G.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2010, 51 (03): : 383 - 389
  • [3] Endovascular stent-grafting via the aortic arch for distal aortic arch aneurysm: an alternative to endovascular stent-grafting
    Orihashi, K
    Sueda, T
    Watari, M
    Okada, K
    Ishii, O
    Matsuura, Y
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 973 - 978
  • [4] Re: Type A Aortic Dissection with Expanding Abdominal Aortic Aneurysm: Treatment with Endovascular Stent-Grafting
    Noriyuki Kato
    Takatsugu Shimono
    Tadanori Hirano
    Masaki Ishida
    Isao Yada
    Kan Takeda
    CardioVascular and Interventional Radiology, 2002, 25 : 227 - 228
  • [5] Re: Type a aortic dissection with expanding abdominal aortic aneurysm: Treatment with endovascular stent-grafting
    Kato, N
    Shimono, T
    Hirano, T
    Ishida, M
    Yada, I
    Takeda, K
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 25 (03) : 227 - 228
  • [6] Endovascular stent-grafting for descending thoracic aortic aneurysm
    Heijmen, RH
    Deblier, IG
    Moll, FL
    Dossche, KM
    van den Berg, JC
    Overtoom, TT
    Ernst, SM
    Schepens, MA
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (01) : 5 - 9
  • [7] Radiation exposure in stent-grafting of abdominal aortic aneurysms
    Geijer, H
    Larzon, T
    Popek, R
    Beckman, KW
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (934): : 906 - 912
  • [8] Branched endovascular stent-graft for suprarenal aortic aneurysm: the future of aortic stent-grafting?
    Tse, LW
    Steinmetz, OK
    Abraham, CZ
    Valenti, DA
    MacKenzie, KS
    Obrand, DI
    Chuter, TA
    CANADIAN JOURNAL OF SURGERY, 2004, 47 (04) : 257 - 262
  • [9] Endovascular stent-grafting via the aortic arch for distal aortic arch aneurysm: an alternative to endovascular stent-grafting - Appendix A. Conference discussion
    Sarsam, M
    Orihashi
    Griepp, R
    Turina
    Bachet, J
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 978 - 978
  • [10] Stent-grafting for a thoracic aortic aneurysm ruptured into the right pleural cavity
    Kurimoto, Y
    Morishita, K
    Kawaharada, N
    Fukada, J
    Abe, T
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (02) : 185 - 187