Robot-assisted percutaneous scaphoid fracture fixation: a report of ten patients

被引:27
|
作者
Liu, Bo [1 ]
Wu, Feiran [2 ]
Chen, Shanlin [1 ]
Jiang, Xieyuan [3 ]
Tian, Wei [4 ]
机构
[1] Beijing Ji Shui Tan Hosp, Dept Hand Surg, 31 Xinjiekou East St, Beijing 100035, Peoples R China
[2] Univ Hosp Birmingham, Dept Orthopaed, Birmingham, W Midlands, England
[3] Beijing Ji Shui Tan Hosp, Dept Orthopaed & Traumatol, Beijing, Peoples R China
[4] Beijing Ji Shui Tan Hosp, Dept Spine Surg, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Robotic surgical procedures; scaphoid; wrist injuries; computer-assisted surgery; SCREW FIXATION; 3-DIMENSIONAL FLUOROSCOPY; NAVIGATION; PLACEMENT; WAIST; INSERTION;
D O I
10.1177/1753193419848595
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study reports the technique, efficacy and safety of robotic-assisted, computer-navigated, percutaneous fixation of scaphoid fractures. Ten males with acute undisplaced waist fractures underwent fixation with this method using a commercially available three-dimensional fluoroscopy unit and robotic navigation system. The mean total operative duration was 40 minutes, which comprised of a set-up time of 18 minutes and planning and surgical time of 22 minutes. All patients required only a single guidewire insertion attempt, and there were no screw protuberances or other complications. All fractures united at a mean of 8 weeks. At a mean follow-up of 6.5 months (range 6-8), the mean Mayo wrist score was 96, patient-rated wrist evaluation was 2, flexion-extension arc was 96% and grip strength was 91% of the contralateral side. We conclude from our patients that robotic-assisted percutaneous scaphoid fixation is feasible, safe and accurate, and is a satisfactory method for treating these injuries.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 50 条
  • [21] Percutaneous cannulated screw fixation of acute scaphoid waist fracture
    Yip, HSF
    Wu, WC
    Chang, RYP
    So, TYC
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (01): : 42 - 46
  • [22] Percutaneous Robot-Assisted versus Freehand S2 Iliosacral Screw Fixation in Unstable Posterior Pelvic Ring Fracture
    Han, Wei
    Zhang, Teng
    Su, Yong-Gang
    Zhao, Chun-Peng
    Zhou, Li
    Wu, Xin-Bao
    Wang, Jun-Qiang
    ORTHOPAEDIC SURGERY, 2022, 14 (02) : 221 - 228
  • [23] Robot-assisted percutaneous cannulated screw fixation in the treatment of slipped capital femoral epiphysis
    Xu, Yunfeng
    Fu, Gang
    Feng, Chao
    Huang, Lin
    Ma, Yuan
    Zhang, Yucheng
    Zhou, Yuan
    Luo, Xiao
    Lu, Ming
    Yang, Jie
    Wang, Yukun
    Lv, Xuemin
    Jiang, Xieyuan
    Yang, Zheng
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2025, 19 (02) : 158 - 165
  • [24] Computer-Assisted Percutaneous Scaphoid Fixation: Concepts and Evolution
    Smith, Erin J.
    Ellis, Randy E.
    Pichora, David R.
    JOURNAL OF WRIST SURGERY, 2013, 2 (04) : 299 - 305
  • [25] Arthroscopic assisted percutaneous fixation in ankle pilon fracture: A case report
    Pradana, Ananto Satya
    Mustamsir, Edi
    Phatama, Krisna Yuarno
    Putra, Domy Pradana
    Oktafandi, I. Gusti Ngurah Arga Aldrian
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2024, 115
  • [26] Robot-Assisted Percutaneous Balloon Compression in Elderly Patients with Trigeminal Neuralgia
    Tan, Ke
    Li, Jinping
    Peng, Yutao
    Wu, Wenqian
    Yang, Ziwen
    Wang, Yu
    Wang, Yang
    JOURNAL OF PAIN RESEARCH, 2023, 16 : 1161 - 1168
  • [27] Feasibility of Percutaneous Robot-Assisted Epiduroscopic System
    Shin, Dong Ah
    Kim, Chunwoo
    Yudoyono, Farid
    Yun, Yeomin
    Ha, Yoon
    Kang, Sungchul
    PAIN PHYSICIAN, 2018, 21 (05) : E565 - E571
  • [28] Robot-assisted Percutaneous Cannulated Screw Fixation of Femoral Neck Fractures: Preliminary Clinical Results
    Duan, Sheng-jun
    Liu, Hua-shui
    Wu, Wen-cheng
    Yang, Kun
    Zhang, Zhen
    Liu, Shi-dong
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 34 - 41
  • [29] Percutaneous screw fixation for scaphoid nonunion in skeletally immature patients: A report of two cases
    Jeon, In-Ho
    Kochhar, Hemanshu
    Lee, Byung-Woo
    Kim, Shin Yoon
    Kim, Poong-Taek
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 656 - 659
  • [30] Robot-assisted Long Bone Fracture Reduction
    Westphal, Ralf
    Winkelbach, Simon
    Wahl, Friedrich
    Goesling, Thomas
    Oszwald, Markus
    Huefner, Tobias
    Krettek, Christian
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2009, 28 (10): : 1259 - 1278