Toward consistent radiometric calibration of the NOAA AVHRR visible and near-infrared data record

被引:2
|
作者
Bhatt, Rajendra [1 ]
Doelling, David R. [2 ]
Scarino, Benjamin R. [1 ]
Gopalan, Arun [1 ]
Haney, Conor O. [1 ]
机构
[1] SSAI, Hampton, VA 23666 USA
[2] NASA, Langley Res Ctr, Hampton, VA 23681 USA
来源
EARTH OBSERVING SYSTEMS XX | 2015年 / 9607卷
关键词
AVHRR; MODIS; SCIAMACHY; calibration; invariant targets; HIGH-RESOLUTION RADIOMETER; IR BANDS; STABILITY; CHANNELS; DESERT; SPACECRAFT;
D O I
10.1117/12.2186816
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 35-year Advanced Very High Resolution Radiometer (AVHRR) satellite-instrument data record is critical for studying decadal climate change, provided that the AVHRR sensors are consistently calibrated. Owing to the lack of onboard calibration capability, the AVHRR data need to be adjusted using vicarious approaches. One of the greatest challenges hampering these vicarious calibration techniques, however, is the degrading orbits of the NOAA satellites that house the instruments, or, more specifically, the fact that the satellites eventually drift into a terminator orbit several years after launch. This paper presents a uniform sensor calibration approach for the AVHRR visible (VIS) and near-infrared (NIR) records using specifically designed NOAA-16 AVHRR-based, top-of-atmosphere (TOA) calibration models that take into account orbit degradation. These models are based on multiple invariant Earth targets, including Saharan deserts, polar ice scenes, and tropical deep-convective clouds. All invariant targets are referenced to the Aqua-MODIS Collection-6 calibration via transfer of the Aqua-MODIS calibration to NOAA-16 AVHRR using simultaneous nadir overpass (SNO) comparisons over the North Pole. A spectral band adjustment factor, based on SCanning Imaging Absorption SpectroMeter for Atmospheric CartograpHY (SCIAMACHY) spectral radiances, is used to account for the spectrally-induced biases caused by the spectral response function (SRF) differences of the AVHRR and MODIS sensors. Validation of the AVHRR Earth target calibration is performed by comparisons with contemporary MODIS SNOs. Calibration consistency between Earth targets validates the historical AVHRR record.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] CALIBRATION OF PRISM SPECTROMETERS IN THE ULTRAVIOLET, VISIBLE AND NEAR-INFRARED REGIONS
    ZWERDLING, S
    THERIAULT, JP
    [J]. SPECTROCHIMICA ACTA, 1961, 17 (08): : 819 - 856
  • [32] Radiometric calibration of the visible and near-infrared bands of SEVIRI using rayleigh scattering and Sun-glint over oceans
    Nicolas, Jean-Marc
    Deschamps, Pierre-Yves
    Hagolle, Olivier
    [J]. PROCEEDINGS OF THE 3RD MSG RAO WORKSHOP, 2006, 619 : 19 - +
  • [33] Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration (vol 17, 1793, 2017)
    Obata, Kenta
    Tsuchida, Satoshi
    Yamamoto, Hirokazu
    Thome, Kurt
    [J]. SENSORS, 2020, 20 (14)
  • [34] Uncertainty analysis of visible and near-infrared data of hydrocarbons
    Venkataramanan, Lalitha
    Fujisawa, Go
    Mullins, Oliver C.
    Vasques, Ricardo R.
    Valero, Henri-Pierre
    [J]. APPLIED SPECTROSCOPY, 2006, 60 (06) : 653 - 662
  • [35] Radiometric and spectral characterization and comparison of the Antarctic Dome C and Sonoran Desert sites for the calibration and validation of visible and near-infrared radiometers
    Uprety, Sirish
    Cao, Changyong
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2012, 6
  • [36] Inter-calibration of meteorological satellite sensors in the visible and near-infrared
    Rao, CRN
    Zhang, N
    Sullivan, JT
    [J]. CALIBRATION AND CHARACTERIZATION OF SATELLITE SENSORS AND ACCURACY OF DERIVED PHYSICAL PARAMETERS, 2001, 28 (01): : 3 - 10
  • [37] Calibration of Visible and Near-infrared Imaging Spectrometer (VNIS) on lunar surface
    Xu Rui
    Lv Gang
    Ma Yan-hua
    Wang Jian-yu
    [J]. MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL REMOTE SENSING TECHNOLOGY, TECHNIQUES AND APPLICATIONS V, 2014, 9263
  • [38] FPGA-based data processing module design of on-board radiometric calibration in visible/near infrared bands
    Zhou, Guoqing
    Li, Chenyang
    Yue, Tao
    Liu, Na
    Jiang, Linjun
    Sun, Yue
    Li, Mingyan
    [J]. INTERNATIONAL CONFERENCE ON INTELLIGENT EARTH OBSERVING AND APPLICATIONS 2015, 2015, 9808
  • [39] Calibration of METEOSAT infrared radiometer using split window channels of NOAA AVHRR
    Asem, A.
    Deschamps, P.Y.
    Ho, D.
    [J]. Journal of Atmospheric and Oceanic Technology, 1987, 4 (04) : 553 - 562
  • [40] Radiometric model of lunar based on GF-4 visible and near-infrared sensor
    Tan, Wei
    Qi, Wenwen
    Wu, Yunzhao
    He, Hongyan
    Chen, Xuan
    [J]. OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY VII, 2020, 11550