Mitochondria-Targeted Fluorescent and Photoacoustic Imaging of Hydrogen Peroxide in Inflammation

被引:63
|
作者
Chen, Xiaoxia [1 ,2 ]
Ren, Xingxing [3 ,4 ]
Zhang, Lele [1 ,2 ]
Liu, Zhengjie [1 ,2 ]
Hai, Zijuan [1 ,2 ]
机构
[1] Anhui Univ, Inst Phys Sci, Key Lab Struct & Funct Regulat Hybrid Mat, Minist Educ, Hefei 230601, Anhui, Peoples R China
[2] Anhui Univ, Inst Informat Technol, Hefei 230601, Anhui, Peoples R China
[3] Univ Sci & Technol China, Inst Immunol, Hefei 230027, Anhui, Peoples R China
[4] Univ Sci & Technol China, Sch Basic Med Sci, Div Life Sci & Med, CAS Key Lab Innate Immun & Chron Dis, Hefei 230027, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
REACTIVE OXYGEN; PROBE; THERANOSTICS; ULTRASOUND; NANOPROBE; BIOLOGY; STRESS; H2O2;
D O I
10.1021/acs.analchem.0c03506
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide (H2O2) is a prominent reactive oxygen species with relative stability, which makes it a potential diagnostic marker for pathological states. Excessive H2O2 in mitochondria leads to oxidative stress and inflammation. However, precisely monitoring the level of H2O2 at specific organelles (e.g., mitochondria) in vivo is still of urgent necessity. Therefore, we rationally designed a mitochondria-targeted near-infrared probe TPP-HCy-BOH for fluorescent/photoacoustic (FL/PA) dual-modal imaging of overproduced H2O2 in an inflamed mouse model. TPP-HCy-BOH had a low LOD (0.348 mu M), which is comparable to those of recently reported probes for H2O2 detection. The high kinetic rate constant (k(obs) = 4.72 x 10(-3) s(-1)) of TPP-HCy-BOH toward H2O2 is superior to recently reported H2O2 probes. Compared to control probe HCy-BOH without the mitochondrial targeting moiety, TPP-HCy-BOH successfully images exogenous or endogenous H2O2 in mitochondria with an additional 2.4-fold FL increase and 4.7-fold PA increase in HeLa cells or additional 2.1-fold FL increase and 3.3-fold PA increase in RAW 264.7 cells. In LPS-induced acute inflammation in vivo, TPP-HCy-BOH is more competent to image overproduced H2O2 with additional 1.6-fold higher sensitivity of FL in abdomen and 2.0-fold higher sensitivity of PA in liver and longer retention time of 0.5 h than HCy-BOH. We anticipate that TPP-HCy-BOH could be employed for the FL/PA dual-modal diagnosis of pathological inflammation in clinic in near future.
引用
收藏
页码:14244 / 14250
页数:7
相关论文
共 50 条
  • [31] A targetable fluorescent probe for imaging hydrogen peroxide in the mitochondria of living cells
    Dickinson, Bryan C.
    Chang, Christopher J.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (30) : 9638 - +
  • [32] Mitochondrial Hydrogen Peroxide in Endothelial Oxidative Stress and Hypertension. Effect of Mitochondria-Targeted Antioxidants
    Dikalov, Sergey
    Nazarewicz, Rafal
    Bikineyeva, Alfiya
    Dikalova, Anna
    FREE RADICAL BIOLOGY AND MEDICINE, 2013, 65 : S70 - S71
  • [33] An Activatable Cancer-Targeted Hydrogen Peroxide Probe for Photoacoustic and Fluorescence Imaging
    Weber, Judith
    Bollepalli, Laura
    Belenguer, Ana M.
    Di Antonio, Marco
    De Mitri, Nicola
    Joseph, James
    Balasubramanian, Shankar
    Hunter, Christopher A.
    Bohndiek, Sarah E.
    CANCER RESEARCH, 2019, 79 (20) : 5407 - 5417
  • [34] A Mitochondria-Targeted Photosensitizer for Combined Pyroptosis and Apoptosis with NIR-II Imaging/Photoacoustic Imaging-Guided Phototherapy
    Wang, Ben
    Zhou, Hui
    Chen, Lu
    Ding, Yancheng
    Zhang, Xinyue
    Chen, Huiyu
    Liu, Hanyu
    Li, Ping
    Chen, Ying
    Yin, Chao
    Fan, Quli
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024, 63 (39)
  • [35] Peptide-directed synthesis of fluorescent gold nanoparticles for mitochondria-targeted confocal imaging of temperature
    Hong Huang
    Hua Li
    Jiu-Ju Feng
    Ai-Jun Wang
    Microchimica Acta, 2017, 184 : 1215 - 1221
  • [36] Real-Time Evaluation of Hydrogen Peroxide Injuries in Pulmonary Fibrosis Mice Models with a Mitochondria-Targeted Near-Infrared Fluorescent Probe
    Song, Xinyu
    Bai, Song
    He, Na
    Wang, Rui
    Xing, Yanlong
    Lv, Changjun
    Yu, Fabiao
    ACS SENSORS, 2021, 6 (03) : 1228 - 1239
  • [37] A long-wavelength mitochondria-targeted fluorescent probe for imaging of peroxynitrite during dexamethasone treatment
    Tang, Jun
    Li, Ziyi
    Qiang, Chuchu
    Han, Yan
    Yang, Lifang
    Zhu, Li
    Dang, Tan
    Chen, Gairong
    Ye, Yong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 292
  • [38] Peptide-directed synthesis of fluorescent gold nanoparticles for mitochondria-targeted confocal imaging of temperature
    Huang, Hong
    Li, Hua
    Feng, Jiu-Ju
    Wang, Ai-Jun
    MICROCHIMICA ACTA, 2017, 184 (04) : 1215 - 1221
  • [39] Mitochondria-targeted fluorescent thermometer monitors intracellular temperature gradient
    Arai, Satoshi
    Suzuki, Madoka
    Park, Sung-Jin
    Yoo, Jung Sun
    Wang, Lu
    Kang, Nam-Young
    Ha, Hyung-Ho
    Chang, Young-Tae
    CHEMICAL COMMUNICATIONS, 2015, 51 (38) : 8044 - 8047
  • [40] A selective mitochondria-targeted fluorescent probe for imaging cysteine in drug-induced liver injury
    Qin, Guixin
    Gao, Lingli
    Yin, Nan
    Wang, Mingxiu
    Wang, Yuting
    Tang, Jiali
    Gong, Jianhua
    Xu, Qingling
    TALANTA, 2025, 282