Preoperative detection of parathyroid adenomas with Tc-99m MIBI and Tc-99m pertechnetate scintigraphy: histopathological and biochemical correlation with Tc-99m MIBI uptake

被引:0
|
作者
Akin, Murat [1 ]
Atasever, Tamer [2 ]
Kurukahvecioglu, Osman [1 ]
Dogan, Mehmet [3 ]
Gokaslan, Devrim [2 ]
Poyraz, Aylar [3 ]
Koksal, Hande [1 ]
Taneri, Ferit [1 ]
机构
[1] Gazi Univ, Sch Med, Dept Gen Surg, Ankara, Turkey
[2] Gazi Univ, Sch Med, Dept Nucl Med, Ankara, Turkey
[3] Gazi Univ, Sch Med, Dept Pathol, Ankara, Turkey
关键词
Tc-99m MIBI; Tc-99m pertechnetate; parathyroid adenoma; oxyphill cell; parathyroid hormone; HIGH-RESOLUTION ULTRASONOGRAPHY; 99M SESTAMIBI SCINTIGRAPHY; PRIMARY HYPERPARATHYROIDISM; DOUBLE-PHASE; LOCALIZATION; TECHNETIUM-99M-SESTAMIBI; GLANDS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The objective of this study was to compare the dual phase MIBI scinitgraphy with MIBI and Tc-99m pertechnetate (MIBI + Tc-99m) study in defining the parathyroid adenomas, and to evaluate the effect of histologic and biochemical characteristics on the imaging of parathyroid adenomas with Tc-99m methoxyisobutylisonitrile (MIBI) scintigraphy. Methods: Thirty-six patients with parathyroid adenomas were studied prospectively. All patients were evaluated with both MIBI and (MIBI + Tc-99m) study. MIBI uptake of adenomas correlated with oxyphill, chief cell and tumour weight of the surgically excised glands. MIBI uptake was also compared with serum calcium (Ca), phosphorus (P) and intact parathormone (iPTH) levels. Results: A total of 38 parathyroid adenomas were surgically excised from 36 patients. MIBI + Tc-99m identified 35 of the parathyroid lesions (92 %). Whereas, MIBI study detected 30 of the 38 parathyroid adenomas (79 % sensitivity) (p=0.0001). There were no false positives. Adenoma weight showed significiant correlation with MIBI uptake (p=0.001). Oxyphyill cell content also showed high correlation with MIBI uptake. Delayed images showed better correlation than the early views (Early MIBI p=0.033; Delayed MIBI; p=0.001). Conclusion: MIBI + Tc-99m pertechnetate interpretation is more sensitive than only dual MIBI imaging for the detection of parathyroid adenoma. Oxyphill cell content and weight of the lesions proved to be important determinants of 99mTc-MIBI accumulation in parathyroid adenoma. We found no significant correlation between MIBI accumulation, Ca, P and iPTH serum levels (Tab. 2, Fig. 2, Ref. 15). Full Text (Free, PDF) www.bmj.sk.
引用
下载
收藏
页码:166 / 169
页数:4
相关论文
共 50 条
  • [11] The comparision of Tc-99m MIBI and Tc-99m MDP scintimammography in detection of breast lesions
    Atalay, M
    Uluc, E
    Polat, M
    Gür, S
    Çökmez, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1119 - 1119
  • [12] Ocular malignant melanoma detected with Tc-99m MIBI and Tc-99m HMPAO
    Sarikaya, I
    Ibis, E
    Günalp, I
    Aras, G
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (08) : 624 - 625
  • [13] Comparison of Tc-99m MIBI and Tl-201/Tc-99m pertechnetate for diagnosis of primary hyperparathyroidism
    Rauth, JD
    Sessions, RB
    Shupe, SC
    Ziessman, HA
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (08) : 602 - 608
  • [14] Primary osteogenic sarcoma of breast detected on Tc-99m MIBI scintigraphy and Tc-99m MDP skeletal scintigraphy
    Yang, Ji-Gang
    Li, Chun-Lin
    Hao, Rui-Rui
    Zou, Lan-Fang
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (01) : 79 - 82
  • [15] Hepatic and splenic uptake of Tc-99m HDP in multiple myeloma: Additional findings on Tc-99m MIBI and Tc-99m sulfur colloid images
    Berk, F
    Demir, H
    Hacihanefioclu, A
    Arslan, A
    Erdincler, O
    Isgoren, S
    Aktolun, C
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (02) : 137 - 141
  • [16] Primary osteogenic sarcoma of breast detected on Tc-99m MIBI scintigraphy and Tc-99m MDP skeletal scintigraphy
    Ji-Gang Yang
    Chun-Lin Li
    Rui-Rui Hao
    Lan-Fang Zou
    Annals of Nuclear Medicine, 2008, 22 : 79 - 82
  • [17] The Correlation Between Tc-99m MIBI Parathyroid Scintigraphy with PTH, Calcium and Phosphorus in Parathyroid Adenomas
    Imren, Y.
    Bekis, R.
    Ozdogan, O.
    Bayraktar, F.
    Atila, K.
    Durak, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S232 - S232
  • [18] Hepatic and splenic uptake of Tc-99m HDP in multiple myeloma: Additional findings on Tc-99m MIBI and Tc-99m sulfur colloid images
    Fatma Berk
    Hakan Demir
    Abdullah Hacihanefioglu
    Arzu Arslan
    Okan Erdincler
    Serkan Isgoren
    Cumali Aktolun
    Annals of Nuclear Medicine, 2002, 16 : 137 - 141
  • [19] PREOPERATIVE LOCALIZATION OF PARATHYROID CARCINOMA USING TC-99M MIBI
    KITAPCI, MT
    TASTEKIN, G
    TURGUT, M
    CANER, B
    KARS, A
    BARISTA, I
    BEKDIK, C
    CLINICAL NUCLEAR MEDICINE, 1993, 18 (03) : 217 - 219
  • [20] Comparison of Tc-99m THY and Tc-99m MIBI scans for diagnosis of breast lesions
    Gutfilen, B
    da Fonseca, LMB