Sequential determination of chromium(VI) and chromium(III) by potentiometric flow-injection method

被引:2
|
作者
Ohura, H
Imato, T
Matsuo, I
Yamasaki, S
机构
[1] Kyushu Sangyo Univ, Fac Engn, Dept Ind Chem, Higashi Ku, Fukuoka 8138503, Japan
[2] Kyushu Univ, Grad Sch Engn, Dept Chem Syst & Engn, Higashi Ku, Fukuoka 8128581, Japan
关键词
Cr(VI)-Cr(III) speciation; flow injection analysis; potentiometry; redox electrode;
D O I
10.2116/bunsekikagaku.49.59
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid potentiometric FIA method far the sequential determination of Cr(VI) and Cr(III) is described, using both a redox electrode detector and a stream of an Fe(III) - Fe(II) potential buffer containing bromide. A three-channel flow system, a carrier stream (water), a reagent stream (H2SO4 solution or Ce(IV) solution containing H2SO4) and the Fe(III)-Fe(II) potential buffer solution, was constructed by equipping a six-way valve between the stream of the reagent solution and the carrier stream. The valve was used to switch the stream of either the H2SO4 solution or the Ce(IV) solution containing H2SO4 in the reagent solution. For the selective determination of Cr(VI) in a mixed sample of Cr (VI) and Cr(III), the valve was snitched to flow a reagent stream of the H2SO4 solution into the potential buffer solution. Then, Cr(Vl). reacted with the potential buffer, and a peak signal was obtained by the detector. For determining the total chromium, the sum of Cr(VI) and Cr(III), the valve was switched to flow the reagent stream of Ce(TV) solution into the potential buffer solution. Cr(III) in the mixed sample was oxidized to Cr(VI) by Ce(IV) in the reagent stream and a peak signal was obtained by the detector. Cr(III) in the mixed sample was determined by the difference of the peak heights obtained by the two reagent streams. The detection of Cr(VI) was based on the measurement of a large transient potential change due to bromine generated by an oxidation reaction between Cr(VI) and bromide in the potential buffer solution. The linear relationships between the peak heights and the sample concentration were observed over the range of 1 x 10(-6) to 10 x 10(-6) M for Cr(VI) and from 4 x 10(-6) to 4 x 10(-5) M for Cr(III) by using a 0.01 M Fe(III)-Fe(II) potential buffer containing 0.6 NI NaBr and 3.6 M H2SO4.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [31] DETERMINATION OF CHROMIUM(III) AND CHROMIUM(VI) IN WATER USING FLOW-INJECTION ONLINE PRECONCENTRATION WITH SELECTIVE ADSORPTION ON ACTIVATED ALUMINA AND FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETECTION
    SPERLING, M
    XU, SK
    WELZ, B
    ANALYTICAL CHEMISTRY, 1992, 64 (24) : 3101 - 3108
  • [32] POTENTIOMETRIC METHOD FOR THE RAPID-DETERMINATION OF SULFATE IN THE PRESENCE OF CHROMIUM(VI)
    PRASAD, R
    ANALYST, 1979, 104 (1235) : 164 - 167
  • [33] SEQUENTIAL DETERMINATION OF CALCIUM AND NITRATE IONS IN WATERS BY POTENTIOMETRIC FLOW-INJECTION
    ALONSOCHAMARRO, J
    BARTROLI, J
    JUN, S
    LIMA, JLFC
    CONCEICAO, M
    MONTENEGRO, BSM
    ANALYST, 1993, 118 (12) : 1527 - 1532
  • [34] Determination of chromium(VI) with bordeaux red by flow injection spectrophotometry
    Huang Jin
    Zhang Xinshen
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2008, 92 (03): : 124 - 126
  • [35] Flow injection spectrofluorimetric method for determination of chromium(VI) using stopped-flow technique
    Tang, B
    Yue, TX
    Shi, XF
    Wu, JS
    Wang, Y
    ANALYTICAL LETTERS, 2005, 38 (02) : 303 - 315
  • [36] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF CHLORIDE
    TROJANOWICZ, M
    MATUSZEWSKI, W
    ANALYTICA CHIMICA ACTA, 1983, 151 (01) : 77 - 84
  • [37] Simultaneous determination of chromium(VI) and chromium(III) of bioavailable fraction in bottom mud by flow injection-atomic absorption spectroscopy
    Wang Chang
    Xie Wen-Bing
    Liu Jie
    Liu Jian-Tong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 451 - 454
  • [38] Simultaneous Determination of Chromium(VI) and Chromium(III) by Capillary Electrophoresis
    Sadayuki Himeno
    Yoichi Nakashima
    Ken-ichi Sano
    Analytical Sciences, 1998, 14 : 369 - 373
  • [39] Spectrophotometric Determination of Trace Chromium(VI) in Mass Chromium(III)
    Zi Gang XU*
    Chinese Chemical Letters, 2001, (07) : 635 - 636
  • [40] Spectrophotometric determination of trace chromium(VI) in mass chromium(III)
    Xu, ZG
    Wen, XH
    Wu, QZ
    CHINESE CHEMICAL LETTERS, 2001, 12 (07) : 635 - 636