APPLICATION OF THE CHIMNEY CAP AS A METHOD OF IMPROVING THE EFFECTIVENESS OF NATURAL VENTILATION IN BUILDINGS

被引:2
|
作者
Antczak-Jarzabska, Romana [1 ]
Niedostatkiewicz, Maciej [1 ]
机构
[1] Gdansk Univ Technol, 11-12 Gabriela Narutowicza St, PL-80233 Gdansk, Poland
关键词
natural ventilation; chimney cap; ACH; wind effect; effectiveness;
D O I
10.2478/pomr-2020-0058
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Adequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the air inside a building fresh. A prediction of the performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long-term cost savings. The worst time in terms of the efficiency of natural ventilation is the spring-autumn transition period [7]. In order to improve the efficiency of natural ventilation, chimney caps are used, among others. They are designed to improve the chimney effect described in colloquial language as a chimney draft. The chimney effect is a physical phenomenon of the formation of a spontaneous flow of a warmer gas, e.g. air, from the bottom up in stem channels [12]. The article analyses the influence of the chimney cowl on the improvement of the chimney effect in an apartment of a multi-family building with natural ventilation. Long-term tests of the chimney draft were carried out for the case without and with a chimney cap. The paper presents the results of the performance (air change rate, ACH) of natural ventilation for a building with an inlet gap measured for the transitional season (between the heating and the summer season). The measurements were performed during a windy period.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [21] Natural ventilation in northwest buildings
    Department of Architecture, University of Oregon, Energy Studies in Buildings Laboratory, Eugene, OR, United States
    不详
    ASHRAE J, 2006, 1 (47-52):
  • [22] NATURAL VENTILATION OF SHEEP BUILDINGS
    BRUCE, JM
    FARM BUILDING PROGRESS, 1982, (69): : 7 - 8
  • [23] Analysis of natural ventilation in buildings
    Zagorec, M.
    Donjerkovic, P.
    Gradevinar, 2006, 58 (05): : 385 - 393
  • [24] NATURAL VENTILATION OF LIVESTOCK BUILDINGS
    CHRISTIAENS, JPA
    DEBRUYCKERE, M
    REVUE DE L AGRICULTURE, 1977, 30 (02): : 255 - 281
  • [25] Parametric study of a novel combination of solar chimney and radiative cooling cavity for natural ventilation enhancement in residential buildings
    Suhendri, Suhendri
    Hu, Mingke
    Su, Yuehong
    Darkwa, Jo
    Riffat, Saffa
    BUILDING AND ENVIRONMENT, 2022, 225
  • [26] Impact of Wind Pressure Coefficients on the Natural Ventilation Effectiveness of Buildings through Simulations
    Sakiyama, Nayara Rodrigues Marques
    Carlo, Joyce Correna
    Sakiyama, Felipe Isamu Harger
    Abdessemed, Nadir
    Frick, Jurgen
    Garrecht, Harald
    BUILDINGS, 2024, 14 (09)
  • [27] Solar chimney-A passive strategy for natural ventilation
    Khanal, Rakesh
    Lei, Chengwang
    ENERGY AND BUILDINGS, 2011, 43 (08) : 1811 - 1819
  • [28] Application of ANN to explore the potential use of natural ventilation in buildings in Turkey
    Ayata, Tahir
    Arcaklioglu, Erol
    Yildiz, Osman
    APPLIED THERMAL ENGINEERING, 2007, 27 (01) : 12 - 20
  • [29] Natural ventilation performance of classroom with solar chimney system
    Tan, Alex Yong Kwang
    Wong, Nyuk Hien
    ENERGY AND BUILDINGS, 2012, 53 : 19 - 27
  • [30] Application of natural ventilation of residential buildings in hot-humid regions
    喻伟
    沈艳
    丁勇