Comparison of 3-dimensional versus 2-dimensional laparoscopic vision system in total laparoscopic hysterectomy: a retrospective study

被引:16
|
作者
Usta, Taner A. [1 ]
Karacan, Tolga [2 ]
Naki, M. Murat [3 ]
Calik, Aysel [1 ]
Turkgeldi, Lale [2 ]
Kasimogullari, Volkan [1 ]
机构
[1] Bagcilar Educ & Res Hosp, Dept Obstet & Gynecol, TR-34200 Istanbul, Turkey
[2] Kanuni Educ & Res Hosp, Dept Obstet & Gynecol, Istanbul, Turkey
[3] Liv Hosp, Dept Obstet & Gynecol, Istanbul, Turkey
关键词
Laparoscopy; 3-Dimensional laparoscopic vision system; 2 Dimensional laparoscopic vision system; Laparoscopic hysterectomy; IMPROVES SURGICAL PERFORMANCE;
D O I
10.1007/s00404-014-3253-1
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
We compare the results of total laparoscopic hysterectomy (TLH) operations conducted using standard 2-D and 3-D high definition laparoscopic vision systems and discuss the findings with regard to the recent literature. Data from 147 patients who underwent TLH operations with 2-D or 3-D high definition laparoscopic vision systems in Department of Obstetrics and Gynecology, Bagcilar Training and Research Hospital, during 2 year period between December 2010 and December 2012, were reviewed retrospectively. TLH operations were divided into two groups as those performed using 2-D, and those performed using 3-D high definition laparoscopic vision systems. A statistically significant difference was found between the two groups in the operation times (p = 0.037 < 0.05). The mean operation time of the 2-D laparoscopy group (134.2 +/- A 61.8 min) was higher than the 3-D laparoscopy group (116.8 +/- A 38.5 min). No statistically significant difference was found between the 2-D and 3-D groups with respect to major, minor and total complication rates (p = 0.641 > 0.05). The operation time among obese patients was significantly shorter in those in the 3-D laparoscopy group than those in the 2-D group (p = 0.041 < 0.05). Recent literature indicates that 3-D laparoscopy vision system needs to be utilized more often and a higher number of ex vivo and in vivo studies have to be conducted. Furthermore, we believe that the prevalent problems encountered during laparoscopy can be overcome by the development of real-time vision devices and the appropriate training of the laparoscopists. 3-D high definition laparoscopic vision system will help to improve surgical performance and outcome of patients undergoing gynecological minimal invasive surgery.
引用
收藏
页码:705 / 709
页数:5
相关论文
共 50 条
  • [41] 2-DIMENSIONAL VERSUS 3-DIMENSIONAL TRACKING UNDER 2 MODES OF ERROR FEEDBACK
    MIRABELL.A
    HUMAN FACTORS, 1969, 11 (01) : 9 - &
  • [42] 3-Dimensional (3D) vs 2-Dimensional (2D) Simulation Enhances Surgical Skills in Standardized Laparoscopic Tasks
    Collins, Danielle
    Ashraf, Ambreen
    Whelan, Maria
    Balfe, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (03) : S114 - S115
  • [43] Does 3-Dimensional (3D) Vision in Laparoscopic Pyeloplasty improve operating time compared to 2D-Laparoscopic Pyeloplasty?
    Christodoulidou, Michelle
    Zelhof, Bachar
    Napier-Hemy, Richard
    BJU INTERNATIONAL, 2014, 114 : 39 - 39
  • [44] LAPAROSCOPIC RADICAL PROSTATECTOMY WITH USING 3-DIMENSIONAL ENDOSCOPE DISPLAY SYSTEM
    Takiuchi, Hidekazu
    Fukui, Koji
    Yamamoto, Shingo
    Hashizume, Makoto
    Sawada, Kazuya
    Suyama, Satoshi
    Mizoh, Yoshiaki
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A231 - A232
  • [45] A COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL HYDROELASTICITY THEORIES INCLUDING THE EFFECT OF SLAMMING
    AKSU, S
    PRICE, WG
    TEMAREL, P
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1991, 205 (01) : 3 - 15
  • [46] COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL CALCULATIONS OF SUPER PROMPT CRITICAL EXCURSIONS
    BIRKHOFER, A
    SCHMIDT, A
    WERNER, W
    NUCLEAR TECHNOLOGY, 1974, 24 (01) : 7 - 12
  • [47] COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL MAPPING OF IONOSPHERIC ELECTRIC-FIELD
    PARK, CG
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 1979, 84 (NA3): : 960 - 964
  • [48] Reliability of Periocular Anthropometry: A Comparison of Direct, 2-Dimensional, and 3-Dimensional Techniques
    Guo, Yongwei
    Hou, Xiaoyi
    Rokohl, Alexander C.
    Jia, Renbing
    Heindl, Ludwig M.
    DERMATOLOGIC SURGERY, 2020, 46 (09) : E23 - E31
  • [49] CLUSTER VARIATION STUDY OF 2-DIMENSIONAL AND 3-DIMENSIONAL ANNI MODELS
    FINEL, A
    DEFONTAINE, D
    JOURNAL OF METALS, 1984, 36 (12): : 17 - 17
  • [50] ONE-DIMENSIONAL, 2-DIMENSIONAL, OR 3-DIMENSIONAL FIELDS
    FREEMAN, TE
    AMERICAN JOURNAL OF PHYSICS, 1995, 63 (03) : 273 - 274