Measurement of coronary flow velocity and coronary flow reserve during stress echocardiography in pediatric patients: A pilot study

被引:0
|
作者
Toma, Warda S. [1 ]
Human, Derek G. [2 ,3 ,4 ]
De Souza, Astrid M. [2 ,3 ,4 ]
Williams, Lindsey D. [2 ,3 ,4 ]
Hollinger, A. J. [2 ,3 ,4 ]
Potts, James E. [2 ,3 ,4 ]
Sandor, George G. S. [2 ,3 ,4 ]
机构
[1] British Columbia Childrens Hosp, Dept Pediat, Vancouver, BC V6H 3V4, Canada
[2] British Columbia Childrens Hosp, Div Cardiol, Vancouver, BC V6H 3V4, Canada
[3] British Columbia Childrens Hosp, Childrens Heart Ctr, Vancouver, BC V6H 3V4, Canada
[4] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
来源
EXPERIMENTAL & CLINICAL CARDIOLOGY | 2013年 / 18卷 / 03期
关键词
Coronary flow reserve; Pediatric heart transplantation; Stress echocardiography; CARDIAC ALLOGRAFT VASCULOPATHY; HEART-TRANSPLANT RECIPIENTS; TRANSTHORACIC DOPPLER; KAWASAKI-DISEASE; ARTERY-DISEASE; BLOOD-FLOW; CHILDREN; ANGIOGRAPHY; SOCIETY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Measuring coronary flow velocity (CFV) and coronary flow reserve (CFR) using transthoracic Doppler echocardiography represents a novel use of noninvasive imaging for the assessment of cardiac allograft vasculopathy (CAV) in adult heart transplant patients and coronary ischemia in several congenital heart lesions in children. OBJECTIVE: To determine the feasibility of using this technique to measure CFV and CFR during stress testing in pediatric cardiac transplant patients (PCTP). METHODS: Measurements of resting and peak CFV and CFR (peak CFV/resting CFV) were obtained from transthoracic Doppler echocardiograms performed during dobutamine stress echocardiography (n = 11) or semisupine cycle ergometry (n = 9) testing in 15 PCTP. A normal CFR value was defined as >= 2. RESULTS: CFV and CFR were measured in the left anterior descending (n = 4), left main (n = 12), right coronary (n = 4) and circumflex (n = 3) arteries. The median resting and peak CFV were 0.25 m/s (range 0.09 m/s to 0.50 m/s) and 0.65 m/s (range 0.22 m/s to 1.14 m/s), respectively. The median CFR was 2.35 (range 1.35 to 4.38). DISCUSSION: CFV and CFR can be measured in pediatric patients noninvasively using transthoracic echocardiography and without the need for contrast. The evaluation of CFR provides additional information to that obtained by regional wall motion analysis during stress echocardiography as well as left ventricular global physiological responses to stress. This combination could result in improved diagnostic accuracy of testing for CAV. The benefits of these integrated studies are that they are noninvasive, inexpensive and feasible, and do not require PCTP to undergo sedation or invasive procedures. CONCLUSIONS: The present pilot study showed that transthoracic CFR is feasible in pediatric patients. Additional studies are needed to determine its clinical utility as a noninvasive screening tool for CAV in PCTP and other pediatric conditions in which coronary artery disease is suspected.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Comparison of intracoronary Doppler guide wire and transesophageal echocardiography in measurement of flow velocity and coronary flow reserve in the left anterior descending coronary artery
    Gadallah, S
    Thaker, KB
    Kawanishi, D
    Mehra, A
    Lau, S
    Rashtian, M
    Chandraratna, PAN
    AMERICAN HEART JOURNAL, 1998, 135 (01) : 38 - 42
  • [42] Assessment of coronary flow velocity reserve by noninvasive transthoracic doppler echocardiography in patients with angiographically normal coronary arteries
    Yang Ya
    Thomas Bartel
    Li Zhian
    Raimund Erbel
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2005, 25 (5): : 590 - 593
  • [43] Coronary flow velocity reserve in patients with ischemic stroke
    Nakajima, Makoto
    Doi, Hideki
    Hirano, Teruyuki
    Tanaka, Yuko
    Uchino, Makoto
    MEDICAL SCIENCE MONITOR, 2009, 15 (08): : CR383 - CR388
  • [44] Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography - Comparison with invasive technique
    Hozumi, T
    Yoshida, K
    Akasaka, T
    Asami, Y
    Ogata, Y
    Takagi, T
    Kaji, S
    Kawamoto, T
    Ueda, Y
    Morioka, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) : 1251 - 1259
  • [45] Coronary flow velocity and coronary flow velocity reserve in children with ventricular septal defect
    Harada, K
    Aoki, M
    Toyono, M
    Tamura, M
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2004, 202 (02): : 77 - 85
  • [46] Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the right coronary artery by transthoracic Doppler echocardiography: Comparison with intracoronary Doppler guidewire
    Ueno, Y
    Nakamura, Y
    Takashima, H
    Kinoshita, M
    Soma, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) : 1074 - 1079
  • [47] Estimation of coronary sinus blood flow and coronary flow reserve by transthoracic echocardiography
    Ismail, YA
    Abdelmessih, NK
    Wong, I
    Soldo, S
    Chandraratna, PAN
    CIRCULATION, 1996, 94 (08) : 146 - 146
  • [48] Coronary Flow Velocity Reserve during Pharmacologic Stress Echocardiography with Normal Contractility Adds Important Prognostic Value in Diabetic and Nondiabetic Patients
    Lowenstein, Jorge A.
    Caniggia, Cristian
    Rousse, Graciela
    Amor, Miguel
    Sanchez, Maria E.
    Alasia, Diego
    Casso, Norberto
    Garcia, Alicia
    Zambrana, Gustavo
    Lowenstein Haber, Diego M.
    Daru, Victor
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (10) : 1113 - 1119
  • [49] Coronary Flow Velocity Reserve and Survival
    De Bruyne, Bernard
    Penicka, Martin
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (11) : 1086 - 1087
  • [50] Relation between changes in coronary flow velocity and in wall motion for assessing contractile reserve during dobutamine stress echocardiography
    Takeuchi, M
    Yoshitani, H
    Miyazaki, C
    Otani, S
    Sakamoto, K
    Yoshikawa, J
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) : 1290 - 1296