Preliminary analysis for integration of spot-scanning proton beam therapy and real-time imaging and gating

被引:27
|
作者
Shimizu, S. [1 ]
Matsuura, T. [2 ]
Umezawa, M. [3 ]
Hiramoto, K. [4 ]
Miyamoto, N. [2 ]
Umegaki, K. [5 ]
Shirato, H. [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiat Oncol, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Grad Sch Med, Sapporo, Hokkaido, Japan
[3] Hitachi Ltd, Hitachi Res Lab, Tokyo, Japan
[4] Hitachi Ltd, Res & Dev Grp, Tokyo, Japan
[5] Hokkaido Univ, Grad Sch Engn, Div Quantum Sci & Engn, Sapporo, Hokkaido, Japan
来源
基金
日本学术振兴会;
关键词
Gated radiotherapy; Organ motion; Image-guided radiation therapy; Spot-scanning proton beam therapy;
D O I
10.1016/j.ejmp.2014.04.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Spot-scanning proton beam therapy (PBT) can create good dose distribution for static targets. However, there exists larger uncertainty for tumors that move due to respiration, bowel gas or other internal circumstances within the patients. We have developed a real-time tumor-tracking radiation therapy (RTRT) system that uses an X-ray linear accelerator gated to the motion of internal fiducial markers introduced in the late 1990s. Relying on more than 10 years of clinical experience and big log data, we established a real-time image gated proton beam therapy system dedicated to spot scanning. Materials and methods: Using log data and clinical outcomes derived from the clinical usage of the RTRT system since 1999, we have established a library to be used for in-house simulation for tumor targeting and evaluation. Factors considered to be the dominant causes of the interplay effects related to the spot scanning dedicated proton therapy system are listed and discussed. Results/conclusions: Total facility design, synchrotron operation cycle, and gating windows were listed as the important factors causing the interplay effects contributing to the irradiation time and motion-induced dose error. Fiducial markers that we have developed and used for the RTRT in X-ray therapy were suggested to have the capacity to improve dose distribution. Accumulated internal motion data in the RTRT system enable us to improve the operation and function of a Spot-scanning proton beam therapy (SSPT) system. A real-time-image gated SSPT system can increase accuracy for treating moving tumors. The system will start clinical service in early 2014. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:555 / 558
页数:4
相关论文
共 50 条
  • [1] A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size
    Shimizu, Shinichi
    Miyamoto, Naoki
    Matsuura, Taeko
    Fujii, Yusuke
    Umezawa, Masumi
    Umegaki, Kikuo
    Hiramoto, Kazuo
    Shirato, Hiroki
    [J]. PLOS ONE, 2014, 9 (04):
  • [2] Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy
    Miyamoto, N.
    Takao, S.
    Matsuura, T.
    Matsuzaki, Y.
    Yamada, T.
    Fujii, Y.
    Matsuo, Y.
    Kidani, T.
    Egashira, Y.
    Umekawa, T.
    Shimizu, S.
    Shirato, H.
    Umegaki, K.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3678 - 3678
  • [3] An image-guided spot-scanning proton beam therapy gated to real-time tumor-tracking system
    Shirato, H.
    Umegaki, K.
    Shimizu, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S152 - S152
  • [4] Improvement of Accuracy of Spot-Scanning Proton Beam Delivery for Liver Tumor by Real-Time Tumor-Monitoring and Gating System: A Simulation Study
    Matsuura, T.
    Shimizu, S.
    Miyamoto, N.
    Takao, S.
    Toramatsu, C.
    Nihongi, H.
    Yamada, T.
    Fujii, Y.
    Umezawa, M.
    Umegaki, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 497 - 497
  • [5] Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University
    Yamada, T.
    Matsuura, T.
    Toramatsu, C.
    Takao, S.
    Nihongi, H.
    Miyamoto, N.
    Shimizu, S.
    Takayanagi, T.
    Umezawa, M.
    Matsuda, K.
    Umegaki, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 304 - 304
  • [6] A simulation study on the dosimetric benefit of real-time motion compensation in spot-scanning proton therapy for prostate
    Proton Beam Therapy Center, Hokkaido University Hospital, Kita 14 Nishi 5, Sapporo
    060-8648, Japan
    不详
    060-8648, Japan
    不详
    060-8628, Japan
    不详
    060-8648, Japan
    不详
    060-8638, Japan
    [J]. J. Rad. Res., 4 (591-597):
  • [7] A simulation study on the dosimetric benefit of real-time motion compensation in spot-scanning proton therapy for prostate
    Fujii, Yusuke
    Matsuura, Taeko
    Takao, Seishin
    Matsuzaki, Yuka
    Fujii, Takaaki
    Miyamoto, Naoki
    Umegaki, Kikuo
    Nishioka, Kentaro
    Shimizu, Shinichi
    Shirato, Hiroki
    [J]. JOURNAL OF RADIATION RESEARCH, 2017, 58 (04) : 591 - 597
  • [8] Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: An initial phantom study using patient tumor trajectory data
    Matsuura, Taeko
    Miyamoto, Naoki
    Shimizu, Shinichi
    Fujii, Yusuke
    Umezawa, Masumi
    Takao, Seishin
    Nihongi, Hideaki
    Toramatsu, Chie
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Ishikawa, Masayori
    Kinoshita, Rumiko
    Maeda, Kenichiro
    Umegaki, Kikuo
    Shirato, Hiroki
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [9] Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data
    Yoshimura, Takaaki
    Shimizu, Shinichi
    Hashimoto, Takayuki
    Nishioka, Kentaro
    Katoh, Norio
    Taguchi, Hiroshi
    Yasuda, Koichi
    Matsuura, Taeko
    Takao, Seishin
    Tamura, Masaya
    Tanaka, Sodai
    Ito, Yoichi M.
    Matsuo, Yuto
    Tamura, Hiroshi
    Horita, Kenji
    Umegaki, Kikuo
    Shirato, Hiroki
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 10 - 19
  • [10] Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance
    Matsuzaki, Y.
    Jenkins, C.
    Yang, Y.
    Yoshimura, T.
    Fujii, Y.
    Umegaki, K.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3758 - 3759