Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

被引:0
|
作者
Miyamoto, N. [1 ]
Takao, S. [1 ]
Matsuura, T. [1 ]
Matsuzaki, Y. [1 ]
Yamada, T. [2 ]
Fujii, Y. [2 ]
Matsuo, Y. [1 ]
Kidani, T. [3 ]
Egashira, Y. [3 ]
Umekawa, T. [3 ]
Shimizu, S. [2 ]
Shirato, H. [2 ]
Umegaki, K. [4 ]
机构
[1] Hokkaido Univ Hosp, Sapporo, Hokkaido 060, Japan
[2] Hokkaido Univ, Sch Med, Sapporo, Hokkaido 060, Japan
[3] Hitachi Ltd, Hitachi, Ibaraki, Japan
[4] Hokkaido Univ, Fac Engn, Sapporo, Hokkaido 060, Japan
关键词
D O I
10.1118/1.4925996
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3678 / 3678
页数:1
相关论文
共 50 条
  • [1] Development of a System for Evaluating the Actual Dose Distribution in Respiratory-Gated Spot-Scanning Proton Therapy Using Real-Time Image Guidance
    Matsuura, T.
    Hirayama, S.
    Koyano, H.
    Takao, S.
    Fujii, T.
    Yamada, T.
    Fujii, Y.
    Nihongi, H.
    Shimizu, S.
    Umegaki, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2992 - 2992
  • [2] Development of An Applicator for Treating Shallow and Moving Tumors with Respiratory-Gated Spot-Scanning Proton Therapy Using Real-Time Image Guidance
    Matsuura, T.
    Fujii, Y.
    Takao, S.
    Yamada, T.
    Matsuzaki, Y.
    Miyamoto, N.
    Takayanagi, T.
    Fujitaka, S.
    Shimizu, S.
    Shirato, H.
    Umegaki, K.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3207 - 3208
  • [3] Development and Commissioning of A Gated Spot Scanning Proton Beam Therapy System with Real-Time Tumor-Tracking
    Umegaki, K.
    Matsuura, T.
    Takao, S.
    Nihongi, H.
    Yamada, T.
    Miyamoto, N.
    Shimizu, S.
    Matsuda, K.
    Nakamura, F.
    Umezawa, M.
    Hiramoto, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [4] Fundamental Verification of Respiratory-Gated Spot Scanning Proton Beam Therapy
    Hamano, H.
    Hayashi, N.
    Yamakawa, T.
    Yasui, K.
    Kato, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3435 - 3435
  • [5] Preliminary analysis for integration of spot-scanning proton beam therapy and real-time imaging and gating
    Shimizu, S.
    Matsuura, T.
    Umezawa, M.
    Hiramoto, K.
    Miyamoto, N.
    Umegaki, K.
    Shirato, H.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (05): : 555 - 558
  • [6] Development and evaluation of a short-range applicator for treating superficial moving tumors with respiratory-gated spot-scanning proton therapy using real-time image guidance
    Matsuura, Taeko
    Fujii, Yusuke
    Takao, Seishin
    Yamada, Takahiro
    Matsuzaki, Yuka
    Miyamoto, Naoki
    Takayanagi, Taisuke
    Fujitaka, Shinichiro
    Shimizu, Shinichi
    Shirato, Hiroki
    Umegaki, Kikuo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1515 - 1531
  • [7] An image-guided spot-scanning proton beam therapy gated to real-time tumor-tracking system
    Shirato, H.
    Umegaki, K.
    Shimizu, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S152 - S152
  • [8] Clinical implementation of respiratory-gated spot-scanning proton therapy: An efficiency analysis of active motion management
    Gelover, Edgar
    Deisher, Amanda J.
    Herman, Michael G.
    Johnson, Jedediah E.
    Kruse, Jon J.
    Tryggestad, Erik J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (05): : 99 - 108
  • [9] The development and commissioning of a respiratory-gated treatment system for proton therapy
    Lu, H.
    Brett, R.
    Sharp, G.
    Safai, S.
    Jiang, S.
    Madden, T.
    Flanz, J.
    Chen, G.
    Kooy, H.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2215 - +
  • [10] Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University
    Yamada, T.
    Matsuura, T.
    Toramatsu, C.
    Takao, S.
    Nihongi, H.
    Miyamoto, N.
    Shimizu, S.
    Takayanagi, T.
    Umezawa, M.
    Matsuda, K.
    Umegaki, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 304 - 304