PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging

被引:36
|
作者
Chuang, Tzu-Chao
Huang, Teng-Yi
Lin, Fa-Hsuan
Wang, Fu-Nien
Juan, Chun-Jung
Chung, Hsiao-Wen [1 ]
Chen, Cheng-Yu
Kwong, Kenneth K.
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
[3] MIT, Massachusetts Gen Hosp, HMS A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Tri Serv Gen Hosp, Dept Radiol, Taipei, Taiwan
[5] Natl Defense Med Ctr, Taipei, Taiwan
关键词
PROPELLER imaging; parallel imaging; high-resolution diffusion image; PROPELLER-EPI; geometric distortions;
D O I
10.1002/mrm.21064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the echo train length (ETL) in EPI. With an eight-element circularly symmetric RF coil, a parallel acceleration factor of 4 was applied such that, when combined with PROPELLER acquisition, a reduction of geometric distortions by a factor substantially greater than 4 was achieved. The resulting phantom and human brain images acquired with a 256 x 256 matrix and an ETL of only 16 were visually identical in shape to those acquired using the fast spin-echo (FSE) technique, even without field-map corrections. It is concluded that parallel PROPELLER-EPI is an effective technique that can substantially reduce susceptibility-induced geometric distortions at high field strength.
引用
收藏
页码:1352 / 1358
页数:7
相关论文
共 50 条
  • [41] High-resolution inter-ictal SPET and phased-array MRI in partial epilepsy: An imaging comparison with video/EEG and outcome correlation
    Lewis, DH
    Ory, P
    Holmes, MD
    Wilensky, AJ
    Cohen, WA
    Schneider, J
    Ojemann, LM
    Ojemann, GA
    NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (03) : 199 - 206
  • [42] Diffusion Tensor Echo Planar Imaging Using Surface Coil Transceiver with a Semiadiabatic RF Pulse Sequence at 14.1T
    van de Looij, Yohan
    Kunz, Nicolas
    Hueppi, Petra
    Gruetter, Rolf
    Sizonenko, Stephane
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) : 732 - 737
  • [43] Malformations of cortical development: High-resolution MR and diffusion tensor imaging of fiber tracts at 3T
    Lim, CCT
    Yin, H
    Loh, NK
    Chua, VGE
    Hui, F
    Barkovich, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (01) : 61 - 64
  • [44] Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 270 - 276
  • [45] A Combined Solenoid-Surface RF Coil for High-Resolution Whole-Brain Rat Imaging on a 3.0 Tesla Clinical MR Scanner
    Underhill, Hunter R.
    Yuan, Chun
    Hayes, Cecil E.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 883 - 892
  • [46] Fractional anisotropy and mean diffusivity: comparison between 3.0-T and 1.5-T diffusion tensor imaging with parallel imaging using histogram and region of interest analysis
    Fushimi, Yasutaka
    Miki, Yukio
    Okada, Tsutomu
    Yamamoto, Akira
    Mori, Nobuyuki
    Hanakawa, Takashi
    Urayama, Shin-ichi
    Aso, Toshihiko
    Fukuyama, Hidenao
    Kikuta, Ken-ichiro
    Togashi, Kaori
    NMR IN BIOMEDICINE, 2007, 20 (08) : 743 - 748
  • [47] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE ANTERIOR VISUAL PATHWAY IN PATIENTS WITH OPTIC NEUROPATHIES USING FAST SPIN-ECHO AND PHASED-ARRAY LOCAL COILS
    GASS, A
    BARKER, GJ
    MACMANUS, D
    SANDERS, M
    RIORDANEVA, P
    TOFTS, PS
    THORPE, J
    MCDONALD, WI
    MOSELEY, IF
    MILLER, DH
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (05): : 562 - 569
  • [48] High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System
    Kim-Cuong T. Nguyen
    Lawrence H. Le
    Neelambar R. Kaipatur
    Rui Zheng
    Edmond H. Lou
    Paul W. Major
    Annals of Biomedical Engineering, 2016, 44 : 2874 - 2886
  • [49] High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System
    Nguyen, Kim-Cuong T.
    Le, Lawrence H.
    Kaipatur, Neelambar R.
    Zheng, Rui
    Lou, Edmond H.
    Major, Paul W.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (10) : 2874 - 2886
  • [50] Diffuse axonal injury in severe traumatic brain injury visualized using high-resolution diffusion tensor imaging
    Xu, Jian
    Rasmussen, Inge-Andre, Jr.
    Lagopoulos, Jim
    Haberg, Asta
    JOURNAL OF NEUROTRAUMA, 2007, 24 (05) : 753 - 765