PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging

被引:36
|
作者
Chuang, Tzu-Chao
Huang, Teng-Yi
Lin, Fa-Hsuan
Wang, Fu-Nien
Juan, Chun-Jung
Chung, Hsiao-Wen [1 ]
Chen, Cheng-Yu
Kwong, Kenneth K.
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
[3] MIT, Massachusetts Gen Hosp, HMS A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Tri Serv Gen Hosp, Dept Radiol, Taipei, Taiwan
[5] Natl Defense Med Ctr, Taipei, Taiwan
关键词
PROPELLER imaging; parallel imaging; high-resolution diffusion image; PROPELLER-EPI; geometric distortions;
D O I
10.1002/mrm.21064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the echo train length (ETL) in EPI. With an eight-element circularly symmetric RF coil, a parallel acceleration factor of 4 was applied such that, when combined with PROPELLER acquisition, a reduction of geometric distortions by a factor substantially greater than 4 was achieved. The resulting phantom and human brain images acquired with a 256 x 256 matrix and an ETL of only 16 were visually identical in shape to those acquired using the fast spin-echo (FSE) technique, even without field-map corrections. It is concluded that parallel PROPELLER-EPI is an effective technique that can substantially reduce susceptibility-induced geometric distortions at high field strength.
引用
收藏
页码:1352 / 1358
页数:7
相关论文
共 50 条
  • [1] High resolution T2*-weighted Magnetic Resonance Imaging at 3 Tesla using PROPELLER-EPI
    Kraemer, Martin
    Reichenbach, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 164 - 173
  • [2] High-resolution MRI of pancreatic masses with a new circularly polarized body phased-array coil
    K. Engelhard
    H. P. Hollenbach
    European Radiology, 1997, 7 : 643 - 648
  • [3] High-resolution MRI of pancreatic masses with a new circularly polarized body phased-array coil
    Engelhard, K
    Hollenbach, HP
    EUROPEAN RADIOLOGY, 1997, 7 (05) : 643 - 648
  • [4] High-Resolution Diffusion Tensor Imaging With Inner Field-of-View EPI
    Finsterbusch, Juergen
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 987 - 993
  • [5] High resolution phased-array coil MR imaging of pelvic lymph nodes in carcinoma of the uterus: Comparison with standard body coil imaging
    Heuck, AF
    Scheidler, JE
    Kimmig, R
    Steinborn, M
    MuellerLisse, UG
    Reiser, MF
    RADIOLOGY, 1997, 205 : 1209 - 1209
  • [6] High-resolution morphological and biochemical imaging of articular cartilage of the ankle joint at 3.0 T using a new dedicated phased array coil: in vivo reproducibility study
    Welsch, Goetz H.
    Mamisch, Tallal C.
    Weber, Michael
    Horger, Wilhelm
    Bohndorf, Klaus
    Trattnig, Siegfried
    SKELETAL RADIOLOGY, 2008, 37 (06) : 519 - 526
  • [7] High-resolution morphological and biochemical imaging of articular cartilage of the ankle joint at 3.0 T using a new dedicated phased array coil: in vivo reproducibility study
    Goetz H. Welsch
    Tallal C. Mamisch
    Michael Weber
    Wilhelm Horger
    Klaus Bohndorf
    Siegfried Trattnig
    Skeletal Radiology, 2008, 37 : 519 - 526
  • [8] Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries
    Liffers, A
    Quick, HH
    Herborn, CU
    Ermert, H
    Ladd, ME
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 439 - 443
  • [9] High-resolution dynamic MR imaging of hepatocellular carcinoma with a phased array body coil
    Fujita, T
    Honjo, K
    Ito, K
    Matsumoto, T
    Matsunaga, N
    Hamm, B
    RADIOGRAPHICS, 1997, 17 (02) : 315 - 331
  • [10] High-Resolution dynamic MR imaging of hepatocellular carcinoma with a phased-array body coil (vol 17, pg 315, 1997)
    Fujita, J
    Honjo, K
    Ito, K
    Matsumoto, T
    Matsunaga, N
    Hamm, B
    RADIOGRAPHICS, 1997, 17 (03) : 804 - 804