Three-dimensional conformal external beam radiotherapy (3D-CRT) for accelerated partial breast irradiation (APBI) - What is the correct prescription dose?

被引:15
|
作者
Cuttino, Laurie W. [1 ]
Todor, Dorin [1 ]
Pacyna, Lynn [1 ]
Lin, Peck-Sun [1 ]
Arthur, Douglas W. [1 ]
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
brachytherapy; breast cancer; breast-conserving therapy; accelerated partial breast irradiation; dose;
D O I
10.1097/01.coc.0000225409.99284.f2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: This study is an evaluation of the biologic equivalence of the dose prescriptions for brachytherapy and 3-dimensional conformal external beam radiotherapy (3D-CRT) accelerated partial breast irradiation (APBI), using actual patient dose matrix data, and is based on the concept of equivalent uniform biologically effective dose (EUBED). This formalism allows a nonuniform dose distribution to be reduced to an equivalent uniform dose, while also accounting for fraction size. Materials and Methods: Five computed tomography scans were selected from a group of patients treated with multicatheter interstitial APBI. Dose matrices for the brachytherapy plans were computed and analyzed with in-house software. For each patient, the EUBED for the brachytherapy dose matrix was generated based on calculations performed at the voxel-level. These EUBED values were then used to calculate the biologically equivalent fraction size for 3D-CRT (eud). Results: The mean equivalent fraction size (eud(mean)) and maximum equivalent fraction size (eud(max)) were calculated for each patient using 100 different values of the alpha/beta ratio. The eud an ranged from 3.67 to 3.69 Gy, while the eud(max) ranged from 3.79 to 3.82 Gy. For all values of the alpha/beta ratio, the maximum fraction size calculated to deliver a biologically equivalent dose with 3D-CRT was 3.82 Gy, with an equivalent total prescription dose of 38.2 Gy. Conclusion: Utilizing a wide range of established radiobiological parameters, this study suggests that the maximum fraction size needed to deliver a biologically equivalent dose using 3D-CRT is 3.82 Gy supporting the continued use of 3.85Gy BID in the current national cooperative trial.
引用
收藏
页码:474 / 478
页数:5
相关论文
共 50 条
  • [1] 3D conformal external beam radiotherapy (3D-CRT) for accelerated partial breast irradiation (APBI): What is the correct prescription dose
    Cuttino, LW
    Todor, D
    Arthur, DW
    George, R
    Pacyna, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S275 - S275
  • [2] Accelerated partial breast irradiation (APBI): are the current dose prescriptions for brachytherapy and 3D conformal external beam (3D-CRT) equivalent?
    Todor, DA
    Cuttino, LW
    Arthur, DW
    George, R
    Pacyna, L
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S65 - S66
  • [3] Three-Dimensional Conformal External Beam Accelerated Partial Breast Irradiation (3D-APBI): Results of a Phase I Dose Escalation Study
    Taghian, A. G.
    Ancukiewicz, M.
    Smith, B.
    MacDonald, S.
    Specht, M.
    Levy, A.
    Hirsch, A.
    Kachnic, L.
    Powell, S.
    Recht, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S86 - S87
  • [4] Preliminary Results using 3D-conformal External Beam (3D-CRT) Accelerated Partial Breast Irradiation (APBI) with Reduced Treatment Margins
    Horst, K. C.
    Goffinet, D. R.
    Dirbas, F. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S220 - S220
  • [5] Three-Dimensional Conformal External Beam Accelerated Partial Breast Irradiation
    Ognibene, G.
    Horst, K. C.
    Fasola, C. E.
    Goffinet, D. R.
    Dirbas, F. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S274 - S274
  • [6] Three-year outcomes of a once daily fractionation scheme for accelerated partial breast irradiation (APBI) using 3-D conformal radiotherapy (3D-CRT)
    Goyal, Sharad
    Daroui, Parima
    Khan, Atif J.
    Kearney, Thomas
    Kirstein, Laurie
    Haffty, Bruce G.
    CANCER MEDICINE, 2013, 2 (06): : 964 - 971
  • [7] RAPID: A randomized trial of accelerated partial breast irradiation using 3-dimensional conformal radiotherapy (3D-CRT)
    Whelan, T.
    Julian, J.
    Levine, M.
    Berrang, T.
    Kim, D-H
    Gu, C. S.
    Germain, I.
    Nichol, A.
    Akra, M.
    Lavertu, S.
    Germain, F.
    Fyles, A.
    Trotter, T.
    Perera, F.
    Balkwill, S.
    Chafe, S.
    McGowan, T.
    Muanza, T.
    Beckham, W.
    Chua, B.
    Olivotto, I.
    CANCER RESEARCH, 2019, 79 (04)
  • [8] Optimal Time for Initiation of Accelerated Partial Breast Irradiation (APBI) using 3-D Conformal Radiotherapy (3D-CRT) - Preliminary Analysis of CINJ 040801
    Goyal, S.
    Yue, N. J.
    Kearney, T.
    Kirstein, L.
    Rao, M.
    Khan, A. J.
    Zhou, J.
    Narra, V.
    Haffty, B. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S210 - S211
  • [9] Lung dose-volume parameters and the risk of pneumonitis for patients treated with accelerated partial-breast irradiation (APBI) using 31) Conformal radiotherapy (3D-CRT)
    Recht, A.
    Ancukiewicz, M.
    Lu, X.
    Ei-Din, M. Alm
    Martin, C.
    MacDonald, S.
    Katz, A.
    Hirsch, A.
    Kachnic, L.
    Taghian, A. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S4 - S5
  • [10] Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy
    Hirata, Kimiko
    Yoshimura, Michio
    Mukumoto, Nobutaka
    Nakamura, Mitsuhiro
    Inoue, Minoru
    Sasaki, Makoto
    Fujimoto, Takahiro
    Yano, Shinsuke
    Nakata, Manabu
    Mizowaki, Takashi
    Hiraoka, Masahiro
    RADIOTHERAPY AND ONCOLOGY, 2017, 124 (01) : 118 - 123