Novel mercuric iodide polycrystalline nuclear particles counters

被引:0
|
作者
Schieber, M
Zuck, A
Braiman, M
Nissenbaum, J
Turchetta, R
Dulinski, W
Husson, D
Riester, JL
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Polycrystalline mercuric iodide nuclear radiation detectors having areas between 0.01 to 100 cm(2) and thicknesses 30 to 600 microns, have been fabricated with single, linear strip and square pixel contacts. The large area detectors 10 to 600 cm(2) were produced by industrial ceramic equipment while the smaller ones, about 1 cm(2) area, were produced in the laboratory. The large detectors still had large leakage currents and the production process is being revised. The smaller detectors were tested and their response to lower and higher gamma energy, beta and even 100 GeV muons at CERN will be reported.
引用
收藏
页码:642 / 646
页数:5
相关论文
共 50 条
  • [31] PRELIMINARY RESULTS ON MERCURIC IODIDE NUCLEAR RADIATION DETECTORS
    PONPON, JP
    STUCK, R
    SIFFERT, P
    SCHWAB, C
    NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (01): : 197 - 198
  • [32] Electrical properties of polycrystalline mercuric iodide X-ray detectors
    Hermon, H
    Street, RA
    Melekhov, L
    Zuck, A
    Vilensky, A
    Ready, SE
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 20 - 27
  • [33] BULK PERFORMANCE OF IMPROVED MERCURIC IODIDE NUCLEAR DETECTORS
    SCHIEBER, M
    BEINGLASS, I
    DISHON, G
    HOLZER, A
    YARON, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 644 - 648
  • [34] REDUCTION OF POLARIZATION IN MERCURIC IODIDE NUCLEAR RADIATION DETECTORS
    HOLZER, A
    SCHIEBER, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 266 - 271
  • [35] Deposition of thick films of polycrystalline mercuric iodide X-ray detectors
    Hermon, H
    Schieber, M
    Zuck, A
    Vilensky, A
    Melekhov, L
    Shtekel, E
    Green, A
    Dagan, O
    Ready, SE
    Street, RA
    Seppi, E
    Pavlyuchkova, R
    Virshup, G
    Zentai, G
    Partain, L
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 133 - 139
  • [36] X-RAY LUMINESCENCE OF MERCURIC IODIDE NUCLEAR DETECTORS
    PINSKY, E
    HALPERIN, A
    BEINGLASS, I
    SCHIEBER, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 260 - 263
  • [37] ADVANCES IN MERCURIC IODIDE SINGLE CRYSTAL NUCLEAR DETECTORS.
    Randtke, P.T.
    Ortale, C.
    Whited, R.C.
    van den Berg, L.
    1976, : 71 - 74
  • [38] CHARGE COLLECTION EFFICIENCY IN MERCURIC IODIDE NUCLEAR-DETECTORS
    BEINGLASS, I
    SCHIEBER, M
    NUCLEAR INSTRUMENTS & METHODS, 1979, 167 (03): : 423 - 426
  • [39] Simulation and characterization of polycrystalline mercuric iodide film detector based on coplanar grid electrode
    Huang, Lu
    Qu, Xingling
    Yang, Weiguang
    Li, Dongmei
    Chen, Yang
    Jin, Jing
    Wang, Linjun
    Zhu, Wenqing
    Ding, Weizhong
    Shi, Weimin
    VACUUM, 2015, 122 : 54 - 58
  • [40] Growth of mercuric iodide (HgI2) for nuclear radiation detectors
    van den Berg, L.
    Schnepple, W.F.
    NASA Technical Memorandum, 1988, 1 (4069): : 269 - 286