Macroscopic Pipe Flow of Micellar Solutions Investigated by Ultrasound Doppler Velocimetry

被引:4
|
作者
Fischer, Peter [1 ]
Ouriev, Boris [2 ]
Windhab, Erich J. [1 ]
机构
[1] ETH, Inst Food Sci & Nutr, CH-8092 Zurich, Switzerland
[2] Buhler AG, CH-9240 Uzwil, Switzerland
关键词
Equimolar viscoelastic surfactant solution; non-linear flow response; shear-banding structure; flow instabilities; Ultrasound Doppler Velocimetry; VELOCITY PROFILE MEASUREMENT; SHEAR-THICKENING TRANSITION; WORMLIKE MICELLES; SURFACTANT SOLUTIONS; INHOMOGENEOUS FLOWS; TRANSIENT-BEHAVIOR; RHEOLOGY; VISUALIZATION; STRESS; BIREFRINGENCE;
D O I
10.3139/113.110016
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Macroscopic flow properties of viscoelastic surfactant solution are investigated in pressure driven pipe flow condition. We focus on an equimolar aqueous solution of cetylpyridinium chloride sodium salicylate, which in simple shear flow exhibits a shear thinning, and at higher shear rates, a pronounced shear-thickening behavior associated with the formation of shear bands [1-6]. An ultrasound Doppler velocimetry method is used to detect these shear bands in pipe flow. The emitted ultrasonic beam is scattered by the moving sample and the time delay between emitted pulse and received echoes as well as the frequency shift is determined. This Doppler shift is related to the speed and the direction of the moving scatters and with this information, the velocity profile across the pipe is calculated [7]. The shape of the obtained velocity profile is used to determine the flow properties of the sample and the formation of shear bands at the tube's wall or within the bulk phase. For the investigated solution we do not observe shear band phenomena. This is contrary to previous investigations [5, 6, 8] where shear bands in the order of few tenth of a millimeter were found. Our results suggesting that the banded region is not detectable by the utilized UVP technique.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [41] Investigating the liquid film characteristics of gas-liquid swirling flow using ultrasound doppler velocimetry
    Liang, Fachun
    Fang, Zhaojun
    Chen, Jing
    Sun, Shitao
    AICHE JOURNAL, 2017, 63 (06) : 2348 - 2357
  • [42] Particle image velocimetry of the unstable capillary flow of a micellar solution
    Méndez-Sánchez, AF
    Pérez-González, J
    de Vargas, L
    Castrejón-Pita, JR
    Castrejón-Pita, AA
    Huelsz, G
    JOURNAL OF RHEOLOGY, 2003, 47 (06) : 1455 - 1466
  • [43] ASSESSMENT OF TREATMENT IN RAYNAUDS-PHENOMENON BY DOPPLER ULTRASOUND VELOCIMETRY
    OREILLY, MJG
    TALPOS, G
    ROBERTS, VC
    COTTON, LT
    BRITISH JOURNAL OF SURGERY, 1979, 66 (05) : 365 - 365
  • [44] Velocity measurements in liquid sodium by means of ultrasound Doppler velocimetry
    Eckert S.
    Gerbeth G.
    Experiments in Fluids, 2002, 32 (5) : 542 - 546
  • [45] Velocity measurements in liquid sodium by means of ultrasound Doppler velocimetry
    Eckert, S
    Gerbeth, G
    EXPERIMENTS IN FLUIDS, 2002, 32 (05) : 542 - 546
  • [46] ULTRASONIC BLOOD FLOW SENSING USING DOPPLER VELOCIMETRY
    Case, Michelle
    Micheli, Matthew
    Arroyo, Daniel
    Hillard, Jeremy
    Kocanda, Martin
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2013, 6 (04): : 1298 - 1316
  • [47] 3-DIMENSIONAL DOPPLER VELOCIMETRY OF FLOW JETS
    FOX, MD
    GARDINER, WM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (10) : 834 - 841
  • [48] CUTANEOUS BLOOD-FLOW - LASER DOPPLER VELOCIMETRY
    TUR, E
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 1991, 30 (07) : 471 - 476
  • [49] LASER DOPPLER VELOCIMETRY OF THE RETINAL BLOOD-FLOW
    HILL, DW
    PIKE, ER
    GARDNER, K
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1981, 101 (APR): : 152 - 155
  • [50] Management of large placental chorioangioma with Doppler flow velocimetry
    Nakai, Y
    Nishio, J
    Tsujimura, A
    Imanaka, M
    Ogita, S
    Morihisa, T
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 80 - 81