Standardization of Radiological Evaluation of Dynamic Contrast Enhanced MRI: Application in Breast Cancer Diagnosis

被引:1
|
作者
Furman-Haran, E. [1 ]
Feinberg, M. Shapiro [2 ]
Badikhi, D. [1 ]
Eyal, E. [1 ]
Zehavi, T. [2 ]
Degani, H. [1 ]
机构
[1] Weizmann Inst Sci, IL-76100 Rehovot, Israel
[2] Meir Med Ctr, Kefar Sava, Israel
关键词
Breast cancer diagnosis; Breast MRI; Dynamic contrast enhanced MRI; Three time point; Principal component analysis; INDEPENDENT COMPONENT ANALYSIS; HIGH-SPATIAL-RESOLUTION; DCE-MRI; PARAMETRIC ANALYSIS; TUMOR ANGIOGENESIS; PROSTATE-CANCER; 3-TIME-POINT; MANAGEMENT;
D O I
10.7785/tcrt.2013.600263
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dynamic contrast enhanced MRI is applied as an adjuvant tool for breast cancer detection, diagnosis, and follow-up of therapy. Despite improvements through the years in achieving higher spatial and temporal resolution, it still suffers from lack of scanning and processing standardization, and consequently, high variability in the radiological evaluation, particularly differentiating malignant from benign lesions. We describe here a hybrid method for achieving standardization of the radiological evaluation of breast dynamic contrast enhanced (DCE)-magnetic resonance imaging (MRI) protocols, based on integrating the model based three time point (3TP) method with principal component analysis (PCA). The scanning and image processing procedures consisted of three main steps: 1. 3TP standardization of the MRI acquisition parameters according to a kinetic model, 2. Applying PCA to test cases and constructing an eigenvectors' base related to the contrast-enhancement kinetics and 3. Projecting all new cases on the eigenvectors' base and evaluating the clinical outcome. Datasets of overall 96 malignant and 26 benign breast lesions were recorded on 1.5T and 3T scanners, using three different MRI acquisition parameters optimized by the 3TP method. The final radiological evaluation showed similar detection and diagnostic ability for the three different MRI acquisition parameters. The area under the curve of receiver operating characteristic analysis yielded a value of 0.88 +/- 0.034 for differentiating malignant from benign lesions. This 3TP+PCA hybrid method is fast and can be readily applied as a computer aided diagnostic tool of breast cancer. The underlying principles of this method can be extended to standardize the evaluation of malignancies in other organs.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 50 条
  • [1] Dynamic contrast-enhanced MRI in the diagnosis and management of breast cancer
    Turnbull, Lindsay W.
    NMR IN BIOMEDICINE, 2009, 22 (01) : 28 - 39
  • [2] Quantifying heterogeneity of lesion uptake in dynamic contrast enhanced MRI for breast cancer diagnosis
    Karahaliou, A.
    Vassiou, K.
    Skiadopoulos, S.
    Kanavou, T.
    Yiakoumelos, A.
    Costaridou, L.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [3] Dynamic contrast-enhanced mammography and breast MRI in the diagnosis of breast cancer and detection of tumor size
    Tekinhatun, Muhammed
    Sabir, Nuran
    Erdem, Ergun
    Yilmaz, Sevda
    Ufuk, Furkan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2024, 54 (01) : 249 - 261
  • [4] Radiomics for ultrafast dynamic contrast-enhanced breast MRI in the diagnosis of breast cancer: a pilot study
    Drukker, Karen
    Anderson, Rachel
    Edwards, Alexandra
    Papaioannou, John
    Pineda, Fred
    Abe, Hiroyuki
    Karzcmar, Gregory
    Giger, Maryellen L.
    MEDICAL IMAGING 2018: COMPUTER-AIDED DIAGNOSIS, 2018, 10575
  • [5] Standardization of Breast Dynamic Contrast-enhanced MRI Signal with Application to the Assessment of Background Parenchymal Enhancement Rate
    Medved, Milica
    Tsuchiya, Keiko
    Fan, Xiaobing
    Karczmar, Gregory S.
    Abe, Hiroyuki
    CURRENT MEDICAL IMAGING, 2024, 20
  • [6] Fully automatic breast cancer diagnosis in contrast enhanced MRI
    Mayer, D.
    Vomweg, T. W.
    Faber, H.
    Weinheimer, O.
    Mattiuzzi, M.
    Buscema, M.
    Dueber, C.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 325 - 327
  • [7] Evaluating deep learning techniques for dynamic contrast-enhanced MRI in the diagnosis of breast cancer
    Anderson, Rachel
    Li, Hui
    Ji, Yu
    Liu, Peifang
    Giger, Maryellen
    MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950
  • [8] Dynamic NMR effects in breast cancer dynamic-contrast-enhanced MRI
    Li, Xin
    Huang, Wei
    Morris, Elizabeth A.
    Tudorica, Luminita A.
    Seshan, Venkatraman E.
    Rooney, William D.
    Tagge, Ian
    Wang, Ya
    Xu, Jingang
    Springer, Charles S., Jr.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (46) : 17937 - 17942
  • [9] The role of dynamic contrast-enhanced MRI in cancer diagnosis and treatment
    Turkbey, Baris
    Thomasson, David
    Pang, Yuxi
    Bernardo, Marcelino
    Choyke, Peter L.
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2010, 16 (03) : 186 - 192
  • [10] Evaluation of response to neoadjuvant chemoradiotherapy for locally advanced breast cancer with dynamic contrast-enhanced MRI of the breast
    Drew, PJ
    Kerin, MJ
    Mahapatra, T
    Malone, C
    Monson, JRT
    Turnbull, LW
    Fox, JN
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2001, 27 (07): : 617 - 620