Dynamic contrast-enhanced mammography and breast MRI in the diagnosis of breast cancer and detection of tumor size

被引:2
|
作者
Tekinhatun, Muhammed [1 ]
Sabir, Nuran [2 ]
Erdem, Ergun [3 ]
Yilmaz, Sevda [3 ]
Ufuk, Furkan [2 ]
机构
[1] Dicle Univ, Fac Med, Dept Radiol, Diyarbakir, Turkiye
[2] Pamukkale Univ, Fac Med, Dept Radiol, Denizli, Turkiye
[3] Pamukkale Univ, Fac Med, Dept Gen Surg, Denizli, Turkiye
关键词
Breast cancer; dynamic breast magnetic resonance imaging; contrast-enhanced spectral mammography; SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; TOMOSYNTHESIS; ACCURACY; WOMEN; RISK;
D O I
10.55730/1300-0144.5786
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: The aim of this study is to evaluate the performance of contrast -enhanced mammography (CEM) and dynamic breast MRI techniques for diagnosing breast lesions, assess the diagnostic accuracy of CEM's using histopathological findings, and compare lesion size measurements obtained from both methods with pathological size. Materials and methods: This prospective study included 120 lesions, of which 70 were malignant, in 104 patients who underwent CEM and MRI within a week. Two radiologists independently evaluated the MR and CEM images in separate sessions, using the BIRADS classification system. Additionally, the maximum sizes of lesion were measured. Diagnostic accuracy parameters and the receiver operating characteristics (ROC) curves were constructed for the two modalities. The correlation between the maximum diameter of breast lesions observed in MRI, CEM, and pathology was analyzed. Results: The overall diagnostic values for MRI were as follows: sensitivity 97.1%, specificity 60%, positive predictive value (PPV) 77.3%, negative predictive value (NPV) 93.8%, and accuracy 81.7%. Correspondingly, for CEM, the sensitivity, accuracy, specificity, PPV, and NPV were 97.14%, 81.67%, 60%, 77.27%, and 93.75%, respectively. The ROC analysis of CEM revealed an area under the curve (AUC) of 0.907 for observer 1 and 0.857 for observer 2, whereas MRI exhibited an AUC of 0.910 for observer 1 and 0.914 for observer 2. Notably, CEM showed the highest correlation with pathological lesion size (r = 0.660 for observer 1 and r = 0.693 for observer 2, p < 0.001 for both). Conclusion: CEM can be used with high sensitivity and similar diagnostic performance comparable to MRI for diagnosing breast cancer. CEM proves to be a successful diagnostic method for precisely determining tumor size.
引用
收藏
页码:249 / 261
页数:14
相关论文
共 50 条
  • [1] Implementing the advantages of contrast-enhanced mammography and contrast-enhanced breast MRI in breast cancer staging
    Fallenberg, Eva M.
    EUROPEAN RADIOLOGY, 2025, 35 (01) : 160 - 162
  • [2] Dynamic contrast-enhanced MRI in the diagnosis and management of breast cancer
    Turnbull, Lindsay W.
    NMR IN BIOMEDICINE, 2009, 22 (01) : 28 - 39
  • [3] Breast Cancer Supplemental Screening: Contrast-Enhanced Mammography or Contrast-Enhanced MRI?
    Rashidi, Ali
    Lowry, Kathryn P.
    Sadigh, Gelareh
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (04)
  • [4] Use of contrast-enhanced mammography for diagnosis of breast cancer
    Fischer, Uwe
    Diekmann, Felix
    Helbich, Thomas
    Preibsch, Heike
    Puesken, Michael
    Wenkel, Evelyn
    Wienbeck, Susanne
    Fallenberg, Eva Maria
    RADIOLOGIE, 2023, 63 (12): : 916 - 924
  • [5] Contrast-enhanced spectral mammography (CESM) compared with breast MRI for breast cancer detection.
    Liao, Lydia
    Li, Luna
    Germaine, Pauline
    Tinney, Elizabeth
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (15)
  • [6] The Quality of Tumor Size Assessment by Contrast-Enhanced Spectral Mammography and the Benefit of Additional Breast MRI
    Lobbes, Marc B. I.
    Lalji, Ulrich C.
    Nelemans, Patty J.
    Houben, Ivo
    Smidt, Marjolein L.
    Heuts, Esther
    de Vries, Bart
    Wildberger, Joachim E.
    Beets-Tan, Regina G.
    JOURNAL OF CANCER, 2015, 6 (02): : 144 - 150
  • [7] Impact of background parenchymal enhancement levels on the diagnosis of contrast-enhanced digital mammography in evaluations of breast cancer: comparison with contrast-enhanced breast MRI
    Sachiko Yuen
    Shuichi Monzawa
    Ayako Gose
    Seiji Yanai
    Yoshihiro Yata
    Hajime Matsumoto
    You Ichinose
    Takashi Tashiro
    Kazuhiko Yamagami
    Breast Cancer, 2022, 29 : 677 - 687
  • [8] Impact of background parenchymal enhancement levels on the diagnosis of contrast-enhanced digital mammography in evaluations of breast cancer: comparison with contrast-enhanced breast MRI
    Yuen, Sachiko
    Monzawa, Shuichi
    Gose, Ayako
    Yanai, Seiji
    Yata, Yoshihiro
    Matsumoto, Hajime
    Ichinose, You
    Tashiro, Takashi
    Yamagami, Kazuhiko
    BREAST CANCER, 2022, 29 (04) : 677 - 687
  • [9] Contrast-Enhanced Spectral Mammography: Importance of the Assessment of Breast Tumor Size
    Nicosia, Luca
    Bozzini, Anna Carla
    Latronico, Antuono
    Cassano, Enrico
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (03) : 489 - 490
  • [10] Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size
    E. M. Fallenberg
    C. Dromain
    F. Diekmann
    F. Engelken
    M. Krohn
    J. M. Singh
    B. Ingold-Heppner
    K. J. Winzer
    U. Bick
    D. M. Renz
    European Radiology, 2014, 24 : 256 - 264