共 50 条
Characterisation of optically cleared paper by optical coherence tomography
被引:25
|作者:
Fabritius, T
[1
]
Alarousu, E
[1
]
Prykari, T
[1
]
Hast, J
[1
]
Myllylä, R
[1
]
机构:
[1] Univ Oulu, Dept Elect & Informat Engn, Optoelect & Measurement Tech Lab, Oulu 90014, Finland
关键词:
light coherence;
light transmittance;
optical length;
optical coherence tomography;
refraction index mismatch;
imaging depth;
paper testing;
optical clearing agent;
D O I:
10.1070/QE2006v036n02ABEH013121
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Due to the highly light scattering nature of paper, the imaging depth of optical methods such as optical coherence tomography (OCT) is limited. In this work, we study the effect of refractive index matching on improving the imaging depth of OCT in paper. To this end, four different refractive index matching liquids (ethanol, I-pentanol, glycerol and benzyl alcohol) with a refraction index between 1.359 and 1.538 were used in experiments. Low coherent light transmission was studied in commercial copy paper sheets, and the results indicate that benzyl alcohol offers the best improvement in imaging depth, while also being sufficiently stable for the intended purpose. Constructed cross-sectional images demonstrate visually that the imaging depth of OCT is considerably improved by optical clearing. Both surfaces of paper sheets can be detected along with information about the sheet's inner structure.
引用
收藏
页码:181 / 187
页数:7
相关论文