Microengineered Conductive Elastomeric Electrodes for Long-Term Electrophysiological Measurements with Consistent Impedance under Stretch

被引:20
|
作者
Hu, Dinglong [1 ]
Cheng, Tin Kei [1 ]
Xie, Kai [1 ]
Lam, Raymond H. W. [1 ]
机构
[1] City Univ Hong Kong, Dept Mech & Biomed Engn, Kowloon, Hong Kong, Peoples R China
关键词
biopotential; microstructure; nanoparticle; ECG; PDMS; PHYSIOLOGICAL MEASUREMENTS; BIOMEDICAL APPLICATIONS; SOFT LITHOGRAPHY; HEART-DISEASE; CLINICAL-APPLICATIONS; POLYMER ELECTRODES; DRY ELECTRODE; RECORDINGS; MICROFLUIDICS; STIMULATION;
D O I
10.3390/s151026906
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, we develop a micro-engineered conductive elastomeric electrode for measurements of human bio-potentials with the absence of conductive pastes. Mixing the biocompatible polydimethylsiloxane (PDMS) silicone with other biocompatible conductive nano-particles further provides the material with an electrical conductivity. We apply micro-replica mold casting for the micro-structures, which are arrays of micro-pillars embedded between two bulk conductive-PDMS layers. These micro-structures can reduce the micro-structural deformations along the direction of signal transmission; therefore the corresponding electrical impedance under the physical stretch by the movement of the human body can be maintained. Additionally, we conduct experiments to compare the electrical properties between the bulk conductive-PDMS material and the microengineered electrodes under stretch. We also demonstrate the working performance of these micro-engineered electrodes in the acquisition of the 12-lead electrocardiographs (ECG) of a healthy subject. Together, the presented gel-less microengineered electrodes can provide a more convenient and stable bio-potential measurement platform, making tele-medical care more achievable with reduced technical barriers for instrument installation performed by patients/users themselves.
引用
收藏
页码:26906 / 26920
页数:15
相关论文
共 50 条
  • [21] Long-Term Measurement of Impedance in Chronically Implanted Depth and Subdural Electrodes During Responsive Neurostimulation in Humans
    Sillay, Karl A.
    Rutecki, Paul
    Cicora, Kathy
    Worrell, Greg
    Drazkowski, Joseph
    Shih, Jerry J.
    Sharan, Ashwini D.
    Morrell, Martha J.
    Williams, Justin
    Wingeier, Brett
    BRAIN STIMULATION, 2013, 6 (05) : 718 - 726
  • [22] Characterizing Dry Electrodes Impedance by Parametric Modeling for Arm Wearable Long-term Cardiac Rhythm Monitoring
    Bosnjak, Antonio
    Linares, Pedro
    McLaughlin, James
    Escalona, Omar J.
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [23] STAINLESS-STEEL SKIN STAPLES - A USEFUL ELECTRODE SYSTEM FOR LONG-TERM ELECTROPHYSIOLOGICAL MEASUREMENTS IN NEUROSURGERY
    SCHWERDTFEGER, K
    LUDT, H
    ACTA NEUROCHIRURGICA, 1986, 82 (3-4) : 137 - 140
  • [24] Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography
    Ge Zhang
    Meng Dai
    Lin Yang
    Weichen Li
    Haoting Li
    Canhua Xu
    Xuetao Shi
    Xiuzhen Dong
    Feng Fu
    BioMedical Engineering OnLine, 16
  • [25] Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography
    Zhang, Ge
    Dai, Meng
    Yang, Lin
    Li, Weichen
    Li, Haoting
    Xu, Canhua
    Shi, Xuetao
    Dong, Xiuzhen
    Fu, Feng
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [26] Changes in impedance at the electrode-skin interface of surface EMG electrodes during long-term EMG recordings
    Hewson, DJ
    Duchêne, J
    Hogrel, JY
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3345 - 3348
  • [27] Mitigating the Effects of Electrode Biofouling-Induced Impedance for Improved Long-Term Electrochemical Measurements In Vivo
    Seaton, Blake T.
    Hill, Daniel F.
    Cowen, Stephen L.
    Heien, Michael L.
    ANALYTICAL CHEMISTRY, 2020, 92 (09) : 6334 - 6340
  • [28] Long-Term Validation of Rapid Impedance Spectrum Measurements as a Battery State-of-Health Assessment Technique
    Christophersen, Jon P.
    Morrison, John L.
    Motloch, Chester G.
    Morrison, William H.
    SAE INTERNATIONAL JOURNAL OF ALTERNATIVE POWERTRAINS, 2013, 2 (01) : 146 - 155
  • [29] Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings
    Hewson, DJ
    Hogrel, JY
    Langeron, Y
    Duchêne, J
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (03) : 273 - 279
  • [30] Conductive Characteristics of Indium Tin Oxide Thin Film on Polymeric Substrate under Long-Term Static Deformation
    Dinh-Phuc Tran
    Lu, Hung-, I
    Lin, Chih-Kuang
    COATINGS, 2018, 8 (06):