Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode

被引:6
|
作者
Sadikoglu, Murat [1 ]
Cabuk, Ahmet [2 ]
机构
[1] Univ Tokat Gaziosmanpasa, Fac Educ, Dept Sci Educ, Tokat, Turkey
[2] Univ Tokat Gaziosmanpasa, Fac Sci & Arts, Dept Chem, Tokat, Turkey
来源
关键词
tenoxicam; voltammetric determination; electrochemical reduction; electrochemical polimerization; modified glassy carbon; PHARMACEUTICAL FORMULATIONS; PIROXICAM; NAPROXEN;
D O I
10.20964/2019.05.08
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the electrocatalytic reduction of tenoxicam (TNX) was studied on a 4-aminobenzene sulfonic acid (4-ABSA) modified glassy carbon (GC) electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The modified glassy carbon electrode showed a significant catalytic effect on the reduction of TNX in a wide pH range of 3.0-8.0. The CV technique was used to investigate electrochemical behaviors of TNX and the effect of pH on the reduction reaction. 0.2 M acetate buffer (pH 5.0) was selected as support electrolyte. The voltammetric determination of TNX was performed using differential pulse voltammetry (DPV) technique. The limits of detection (LOD) and quantification (LOQ) were determined to be 2.82x10(-7) M and 9.43x10(-7) M. Also, the amount of TNX in the drug tablets was determined at the optimum conditions developed. It is observed that the modified GC electrode is sensitivity and selectivity for the determination of TNX in Oksamen tablets by DPV technique
引用
收藏
页码:4508 / 4519
页数:12
相关论文
共 50 条
  • [21] Voltammetric determination of paracetamol at C60-modified glassy carbon electrode
    Goyal, RN
    Singh, SP
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (15) : 3008 - 3012
  • [22] Preconcentration and voltammetric determination of mercury(II) at a chemically modified glassy carbon electrode
    Sousa, MDB
    Bertazzoli, R
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1258 - 1261
  • [23] Voltammetric determination of ofloxacin by using a laser-modified carbon glassy electrode
    Feng, Limin
    Xue, Qiang
    Liu, Fei
    Cao, Qipu
    Feng, Jijun
    Yang, Liang
    Zhang, Fuling
    [J]. MICROCHIMICA ACTA, 2020, 187 (01)
  • [24] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    [J]. Microchimica Acta, 2016, 183 : 1459 - 1467
  • [25] Voltammetric determination of ofloxacin by using a laser-modified carbon glassy electrode
    Limin Feng
    Qiang Xue
    Fei Liu
    Qipu Cao
    Jijun Feng
    Liang Yang
    Fuling Zhang
    [J]. Microchimica Acta, 2020, 187
  • [26] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    [J]. MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467
  • [27] Stripping voltammetric determination of Epinephrine applying sulfacetamide modified glassy carbon electrode
    Ahmed, T. A.
    Ghandour, M. A.
    Khalil, M. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (04): : 3143 - 3156
  • [28] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [29] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (09) : 1053 - 1061
  • [30] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    [J]. Journal of the Serbian Chemical Society, 2017, 82 (09): : 1053 - 1061