Library based x-ray scatter correction for dedicated cone beam breast CT

被引:32
|
作者
Shi, Linxi [1 ,2 ,3 ]
Vedantham, Srinivasan [4 ]
Karellas, Andrew [4 ]
Zhu, Lei [1 ,2 ,3 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Nucl Program, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Radiol Engn Program, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Med Phys Program, Atlanta, GA 30332 USA
[4] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
基金
美国国家卫生研究院;
关键词
breast; computed tomography; cone-beam breast CT; scatter correction; Monte Carlo simulation; COMPUTED-TOMOGRAPHY; DIAGNOSTIC POPULATION; RADIATION-THERAPY; IMAGE QUALITY; MAMMOGRAPHY; CANCER;
D O I
10.1118/1.4955121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular / adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors' method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i. e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors' method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors' approach is effective ;and stable, and is therefore clinically attractive for CBBCT imaging. (C) 2016 American Association of Physicists in Medicine
引用
收藏
页码:4529 / 4544
页数:16
相关论文
共 50 条
  • [21] The role of off-focus radiation in scatter correction for dedicated cone beam breast CT
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2018, 45 (01) : 191 - 201
  • [22] A direct, empirical method for x-ray scatter correction in digital radiography and cone-beam CT
    Siewerdsen, J
    Bakhtiar, B
    Moseley, D
    Richard, S
    Keller, H
    Daly, M
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2093
  • [23] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [24] Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio
    Shi, L.
    Vedantham, S.
    Karellas, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3682 - 3682
  • [25] X-Ray Scatter Correction in Breast CT: Advances and Patient Testing
    Ramamurthy, S.
    Sechopoulos, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 478 - 478
  • [26] A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4633 - 4652
  • [27] A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    Siewerdsen, JH
    Daly, MJ
    Bakhtiar, B
    Moseley, DJ
    Richard, S
    Keller, H
    Jaffray, DA
    MEDICAL PHYSICS, 2006, 33 (01) : 187 - 197
  • [28] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [29] Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bose, Supratik
    Hristov, Dimitre H.
    Faddegon, Bruce A.
    Paidi, Ajay
    Bani-Hashemi, Ali R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1791 - 1810
  • [30] Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Lu, HongBing
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783