A sub-ppm automated 10-to-1k V measuring system

被引:0
|
作者
Chien, FSS
Su, TH
Chen, IP
Kuo, JJ
机构
来源
IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2 | 1997年
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We describe an automated de 10-to-1k V measuring system built with simple equipment This PC-controlled system performs a quick automated self-calibration and sub-ppm accuracy voltage measurement The bridge method is adopted in its self-calibration procedure. The analysis of the circuits for self-calibration and voltage measurement is included.
引用
收藏
页码:350 / 352
页数:3
相关论文
共 50 条
  • [41] COATED SURFACE-ACOUSTIC-WAVE SENSOR EMPLOYING A REVERSIBLE MASS-AMPLIFYING LIGAND SUBSTITUTION-REACTION FOR REAL-TIME MEASUREMENT OF 1,3-BUTADIENE AT LOW-PPM AND SUB-PPM CONCENTRATIONS
    ZHANG, GZ
    ZELLERS, ET
    ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1340 - 1349
  • [42] Rapid Determination of Sub-ppm Heavy Metals in the Solution State via Portable X-ray Fluorescence Spectrometry Based on Homogeneous Liquid-Liquid Extraction in a Ternary Component System
    Takeshi Kato
    Yuki Nagashima
    Atsushi Manaka
    Chihiro Nakamura
    Shigekatu Oshite
    Shukuro Igarashi
    Analytical Sciences, 2019, 35 : 939 - 942
  • [43] Rapid Determination of Sub-ppm Heavy Metals in the Solution State via Portable X-ray Fluorescence Spectrometry Based on Homogeneous Liquid-Liquid Extraction in a Ternary Component System
    Kato, Takeshi
    Nagashima, Yuki
    Manaka, Atsushi
    Nakamura, Chihiro
    Oshite, Shigekatu
    Igarashi, Shukuro
    ANALYTICAL SCIENCES, 2019, 35 (08) : 939 - 942
  • [44] The TEST 1 automated system - A new method for measuring the erythrocyte sedimentation rate
    Plebani, M
    De Toni, S
    Sanzari, MC
    Bernardi, D
    Stockreiter, E
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) : 334 - 340
  • [45] AUTOMATED GAS CHROMATOGRAPHIC SYSTEM FOR MEASURING AMBIENT HYDROCARBONS AT SUB-PART-PER-BILLION CONCENTRATIONS.
    Ferman, Martin A.
    Proceedings, Annual Meeting - Air Pollution Control Association, 1980, 3
  • [46] Amplified spontaneous emission in action: Sub-ppm optical detection of acid vapors in poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] thin films
    Guillen, M. G.
    Gamez, F.
    Lopes-Costa, T.
    Castro-Smirnov, J. R.
    Wannemacher, R.
    Cabanillas-Gonzalez, J.
    Pedrosa, J. M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 1354 - 1361
  • [47] A 10.5 ppm/°C Modified Sub-1 V Bandgap in 28 nm CMOS Technology with Only Two Operating Points
    Nagulapalli, Rajasekhar
    Yassine, Nabil
    Tammam, Amr A.
    Barker, Steve
    Hayatleh, Khaled
    ELECTRONICS, 2024, 13 (06)
  • [48] Variation-aware automated design and optimization of sub-1V bandgap voltage reference
    Mohammad, Abdelrahman A.
    Abdalla, Mohamed A. Y.
    Omran, Hesham
    MICROELECTRONICS JOURNAL, 2024, 152
  • [49] Laser Ablation Inductive Coupled Plasma Mass Spectroscopy (LA-ICP-MS) Analysis on Lead-Acid Battery System: Development of Evaluation Method of Sub-ppm Metal Impurity Elements
    Sungyool Bong
    Luqman Azhari
    Yan Wang
    Journal of Sustainable Metallurgy, 2021, 7 : 610 - 619
  • [50] Laser Ablation Inductive Coupled Plasma Mass Spectroscopy (LA-ICP-MS) Analysis on Lead-Acid Battery System: Development of Evaluation Method of Sub-ppm Metal Impurity Elements
    Bong, Sungyool
    Azhari, Luqman
    Wang, Yan
    JOURNAL OF SUSTAINABLE METALLURGY, 2021, 7 (02) : 610 - 619