Modelling of a Single-Channel Beta-Gamma Coincidence Phoswich Detector Using Geant4 for the Conversion Electron Energy Peak Resolution and Beta-Gamma Coincidence Efficiency Improvement

被引:3
|
作者
Zhang, Weihua [1 ]
Mekarski, Pawel [1 ]
Bean, Marc [1 ]
Yi, Jing [1 ]
Ungar, Kurt [1 ]
机构
[1] Radiat Protect Bur Hlth Canada, Ottawa, ON K1A 1C1, Canada
关键词
Phoswich detector design; Monte Carlo simulation; FWHM; xenon radioisotopes; RADIOACTIVE XENON; SYSTEM;
D O I
10.1007/s00024-012-0494-4
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
In this study, an optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404) embedded in a CsI (Tl) crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI (Tl) crystal consists of a rectangular part and a semi-cylinder scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15 % improvement in the energy resolution of a Xe-131m 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.
引用
收藏
页码:621 / 627
页数:7
相关论文
共 29 条
  • [21] A calibration procedure for beta-gamma coincidence detector-systems using four radioxenon spikes
    Liu, Boxue
    Britton, Richard
    Yoon, Seokryung
    Davies, Ashley Vaughan
    Hermanspahn, Nikolaus
    Gohla, Herbert
    Bare, Jonathan
    Kalinowski, Martin
    APPLIED RADIATION AND ISOTOPES, 2024, 205
  • [22] ABSOLUTE MEASUREMENTS OF RADIOACTIVITY USING 4PI BETA-GAMMA COINCIDENCE METHOD
    WOOD, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 133 - &
  • [23] Simulation of beta-gamma coincidence spectra of radioxenon detector using gate 7.0 and comparison with experimental results
    Doost-Mohammadi, V.
    Afarideh, H.
    Etaati, G. R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 309 (03) : 1105 - 1112
  • [24] EFFICIENCY CALIBRATION OF A GE(LI) DETECTOR BY ABSOLUTE COUNTING OF FALLOUT NUCLIDES BY MEANS OF 4PI BETA-GAMMA COINCIDENCE METHOD
    WEINREICH, R
    NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (04): : 601 - 603
  • [25] Single channel beta-gamma coincidence system for radioxenon measurement using well-type HPGe and plastic scintillator detectors
    Xie, Feng
    Jiang, Wengang
    Li, Xuesong
    He, Xiaobing
    Zhang, Jiamei
    Yu, Gongshuo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 900 - 904
  • [26] Compact Beta-Gamma Radioxenon Detection System with Improved Energy Resolution Using PIPS Detector
    Azimi, Sepideh Alsadat
    Afarideh, Hossein
    Chai, Jong-Seo
    PURE AND APPLIED GEOPHYSICS, 2024,
  • [27] Electron-capture effects in activity determination of Ir-192 by a 4 pi beta-gamma coincidence counting method
    Kim, KH
    Shin, SA
    Park, TS
    Lee, YS
    Hwang, HY
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1997, 31 (02) : 241 - 246
  • [28] 4 PI BETA-GAMMA COINCIDENCE METHOD FOR MIXED ELECTRON-CAPTURE/POSITRON EMITTERS - ABSOLUTE MEASUREMENT OF GA-68
    SMITH, D
    WILLIAMS, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (10): : 615 - &
  • [29] A multi-channel beta-gamma coincidence counting system using well-HPGe and plastic scintillation detectors for radioactive Xenon measurements
    Byun, Jong-In
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 949 (949):