Clinical Utility of Stewart's Method in Diagnosis and Management of Acid-Base Disorders

被引:24
|
作者
Rastegar, Asghar [1 ]
机构
[1] Yale Univ, Sch Med, Dept Med, Nephrol Sect, New Haven, CT 06520 USA
关键词
INTENSIVE-CARE-UNIT; STRONG ION GAP; ANION GAP; METABOLIC-ACIDOSIS; UNMEASURED ANIONS; MORTALITY; LACTATE; PREDICTION; CRITIQUE; MODELS;
D O I
10.2215/CJN.01820309
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
For the past 5 decades, a bicarbonate-based approach has been the dominant method used for the diagnosis and treatment of acid-base disorders. This approach, however, has been criticized by some as (1) qualitative and not quantitative in nature and (2) incapable of detecting important diagnoses. Stewart, using principals of electroneutrality and conservation of mass, developed a "new" approach to the diagnosis and management of these disorders. The proponents of Stewart's approach believe that it not only offers a mechanistic explanation for the disorders but also provides the tool to make a more accurate diagnosis. Although Stewart's approach has been largely ignored by nephrologists and renal physiologists, it is increasingly used by anesthesiologists and intensivists. This review discusses the clinical utility of Stewart's method compared with the traditional bicarbonate-based approach. Although Stewart's method proposes a different, however not new, approach, it does not improve our ability to diagnose more accurately or manage these disorders. Stewart's method also does not provide the tool to prognosticate any better than the traditional method. Clin J Am Soc Nephrol 4: 1267-1274, 2009. doi: 10.2215/CJN.01820309
引用
收藏
页码:1267 / 1274
页数:8
相关论文
共 50 条
  • [31] ACID-BASE DISORDERS
    FUH, YJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 223 (03): : 330 - 330
  • [32] In defense of the Stewart approach to acid-base analysis
    Gatz, Rainer K. H.
    Elbers, Paul W. G.
    KIDNEY INTERNATIONAL, 2010, 78 (07) : 711 - 711
  • [33] Stewart Acid-Base: A Simplified Bedside Approach
    Story, David A.
    ANESTHESIA AND ANALGESIA, 2016, 123 (02): : 511 - 515
  • [34] EVALUATION OF STEWART ACID-BASE ANALYSIS IN SWINE
    FRISCHMEYER, KJ
    MOON, PF
    FASEB JOURNAL, 1993, 7 (03): : A21 - A21
  • [35] The role of the clinical laboratory in diagnosing acid-base disorders
    Berend, K.
    Duits, A. J.
    CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2019, 56 (03) : 147 - 169
  • [36] Practical Approach to Physical-Chemical Acid-Base Management Stewart at the Bedside
    Magder, Sheldon
    Emami, Ali
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2015, 12 (01) : 111 - 117
  • [37] NEW METHOD FOR ASSESSMENT OF ACUTE ACID-BASE DISORDERS
    KAPPAGOD.CT
    STOKER, JB
    LINDEN, RJ
    ARCHIVES OF DISEASE IN CHILDHOOD, 1973, 48 (01) : 79 - 80
  • [38] Fuzzy-based framework for diagnosis of acid-base disorders
    Amer, Mashhour Bani
    COMPUTERS IN BIOLOGY AND MEDICINE, 2011, 41 (09) : 737 - 741
  • [39] The Reproducibility of Stewart Parameters for Acid-Base Diagnosis Using Two Central Laboratory Analyzers
    Nguyen, Ba-Vinh
    Vincent, Jean-Louis
    Hamm, Jean Baptiste
    Abalain, Jean-Herve
    Carre, Jean-Luc
    Nowak, Emmanuel
    Ahmed, Mehdi Ould
    Arvieux, Charles C.
    Gueret, Gildas
    ANESTHESIA AND ANALGESIA, 2009, 109 (05): : 1517 - 1523
  • [40] ACID-BASE MANAGEMENT
    KOSTER, R
    CARLI, P
    RESUSCITATION, 1992, 24 (02) : 143 - 146