Electrophoretic characterisation of fractions collected from gluten protein extracts subjected to size-exclusion high-performance liquid chromatography

被引:54
|
作者
Larroque, OR
Gianibelli, MC
Batey, IL
MacRitchie, F
机构
[1] CSIRO,DIV PLANT IND,N RYDE,NSW 2113,AUSTRALIA
[2] UNIV WESTERN SYDNEY,RICHMOND,NSW,AUSTRALIA
[3] NATL UNIV LA PLATA,RA-1900 LA PLATA,ARGENTINA
[4] WHEAT QUAL CRC,N RYDE,NSW,AUSTRALIA
关键词
wheat endosperm proteins; polymeric protein; monomeric protein; high performance liquid chromatography; sodium dodecyl sulfate-polyacrylamide gel electrophoresis; gel scanning;
D O I
10.1002/elps.1150180706
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The electrophoretic analysis by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE; reduced and unreduced) of fractions, collected from a size exclusion-high performance liquid chromatography (SE-HPLC) separation of gluten proteins using a column with pare size of around 400 Angstrom, showed clear resolution for the seven elution ranges studied in two Australian bread wheat lines. Polymeric proteins - high molecular weight (HMW) glutenin subunits, low molecular weight (LMW) glutenin subunits, HMW albumins and some modified omega-gliadins - appeared exclusively in the region within the first peak of the chromatogram (fractions 1 to 5), the limit being a region that resolved as a small peak before the large peal; of gliadins and where some omega-gliadins eluted. A larger proportion of HMW glutenin subunits and B subunits contributed to polymer formation of higher molecular weight. The polymer size decreased as the proportion of the other protein components increased.
引用
收藏
页码:1064 / 1067
页数:4
相关论文
共 50 条
  • [41] Determination of pegfilgrastim aggregates by size-exclusion high-performance liquid chromatography on a methacrylate-based column
    Shahbazi, Majid
    Zahedy, Elnaz Tamaskany
    Kiumarsi, Shiva
    Soltanabad, Mojtaba Hadi
    Azar, Saleh Shahbazi
    Amini, Hossein
    BIOLOGICALS, 2017, 46 : 153 - 158
  • [42] Development of a Quantitative Determination Method for Polysorbate 80 in Biologicals by Size-Exclusion High-Performance Liquid Chromatography
    Rounova, O. B.
    Korotkov, M. G.
    Ustinnikova, O. B.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2024, 57 (12) : 2013 - 2018
  • [43] STRUCTURE OF THE MOUSE GLUCOCORTICOID RECEPTOR - RAPID ANALYSIS BY SIZE-EXCLUSION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LAPOINTE, MC
    CHANG, CH
    VEDECKIS, WV
    BIOCHEMISTRY, 1986, 25 (08) : 2094 - 2101
  • [44] Analysis of antibody-antigen interactions using size-exclusion high-performance (pressure) liquid chromatography
    Sanny, CG
    Price, JA
    ANALYTICAL BIOCHEMISTRY, 1997, 246 (01) : 7 - 14
  • [45] ISOLATION OF DETERGENT-SOLUBILIZED MONOMERS OF BACTERIORHODOPSIN BY SIZE-EXCLUSION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MUCCIO, DD
    DELUCAS, LJ
    JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN): : 243 - 250
  • [46] ANOMALOUS BEHAVIOR OF LECTINS IN SIZE-EXCLUSION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GEL-ELECTROPHORESIS
    YOUNG, NM
    JACKSON, GED
    JOURNAL OF CHROMATOGRAPHY, 1984, 336 (02): : 397 - 402
  • [47] Practical Application of Size-exclusion High Performance Liquid Chromatography in Wheat Analysis
    Buresova, I.
    Hrivna, L.
    Dvorakova, P.
    Sedlackova, I.
    CEREAL RESEARCH COMMUNICATIONS, 2012, 40 (04) : 552 - 561
  • [48] Practical Application of Size-Exclusion High Performance Liquid Chromatography in Wheat Analysis
    I. Burešová
    L. Hřivna
    P. Dvořáková
    I. Sedláčková
    Cereal Research Communications, 2012, 40 : 552 - 561
  • [49] SIZE-EXCLUSION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF THE DODECAMERIC AND HEXAMERIC FORMS OF HEMOCYANIN FROM CALLINECTES-SAPIDUS
    GREAVES, J
    RAINER, JS
    MANGUM, CP
    MARINE BIOLOGY, 1992, 113 (01) : 33 - 36
  • [50] SIZE-EXCLUSION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SEPARATION OF PEPTIDES FROM PEPTIC HEMOGLOBIN HYDROLYSATE OBTAINED BY ULTRAFILTRATION
    PIOT, JM
    GUILLOCHON, D
    THOMAS, D
    CHROMATOGRAPHIA, 1988, 25 (04) : 307 - 312