IMPACT OF LUNG TISSUE THICKNESS ON THE ACCURACY OF DIFFERENT DOSE CALCULATIONS ALGORITHMS FOCUSSED ON STEREOTACTIC BODY THERAPY FOR LUNG TUMOURS

被引:0
|
作者
Pino, F. [1 ]
Navarro, D. [1 ]
De Bias Pinol, R. [1 ]
Modolell i Farre, I. [1 ]
Lizuain, M. C. [1 ]
机构
[1] Inst Catala Oncol, Serv Fis Med & Proteccio Radiol, Lhospitalet De Llobregat, Spain
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1351
引用
收藏
页码:S458 / S458
页数:1
相关论文
共 50 条
  • [21] Dosiomic feature comparison between dose-calculation algorithms used for lung stereotactic body radiation therapy
    Takanori Adachi
    Mitsuhiro Nakamura
    Ryo Kakino
    Hideaki Hirashima
    Hiraku Iramina
    Yusuke Tsuruta
    Tomohiro Ono
    Nobutaka Mukumoto
    Yuki Miyabe
    Yukinori Matsuo
    Takashi Mizowaki
    Radiological Physics and Technology, 2022, 15 : 63 - 71
  • [22] Dosiomic feature comparison between dose-calculation algorithms used for lung stereotactic body radiation therapy
    Adachi, Takanori
    Nakamura, Mitsuhiro
    Kakino, Ryo
    Hirashima, Hideaki
    Iramina, Hiraku
    Tsuruta, Yusuke
    Ono, Tomohiro
    Mukumoto, Nobutaka
    Miyabe, Yuki
    Matsuo, Yukinori
    Mizowaki, Takashi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 63 - 71
  • [23] Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Lu, Bo
    Hallahan, Dennis E.
    Cmelak, Anthony
    Malcolm, Arnold
    Newton, Jared
    Deeley, Matthew
    Coffey, Charles W.
    MEDICAL PHYSICS, 2007, 34 (07) : 2985 - 2994
  • [24] Clinical Impact and Utility of Acuros XB Dose Calculation Algorithm in Lung Stereotactic Body Radiation Therapy
    Clayton, R.
    Liu, H.
    Lau, H.
    Dunscombe, P.
    Nugent, Z.
    Khan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S723 - S724
  • [25] Differences in dose-volumetric data between heterogeneity correction algorithms for stereotactic body radiation therapy for lung cancer: Is there any impact of the algorithms on local control?
    Matsuo, Y.
    Nagata, Y.
    Nakamura, M.
    Narita, Y.
    Shibuya, K.
    Narabayashi, M.
    Mizowaki, T.
    Norihisa, Y.
    Nakata, M.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S638 - S639
  • [26] A COMPARISON OF TWO IMMOBILIZATION SYSTEMS FOR STEREOTACTIC BODY RADIATION THERAPY (SBRT) OF LUNG TUMOURS
    Han, K.
    Basran, P.
    Erler, D.
    Lochray, F.
    Yeung, L.
    Poon, I.
    Cheung, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S5 - S6
  • [27] Stereotactic body radiation therapy for peripheral lung tumours: a study in a French cancer center
    Claude, L.
    Hau, N.
    Martel-Iafay, I.
    Carrie, C.
    Ayadi, M.
    Gassa, F.
    EJC SUPPLEMENTS, 2009, 7 (02): : 538 - 538
  • [28] Setup accuracy and dose attenuation of a wooden immobilization system for lung stereotactic body radiotherapy
    Nitta, Yuya
    Ueda, Yoshihiro
    Murata, Seiya
    Isono, Masaru
    Ohira, Shingo
    Masaoka, Akira
    Inui, Shoki
    Washio, Hayate
    Yoshinaka, Reimi
    Sagawa, Tomohiro
    Miyazaki, Masayoshi
    Teshima, Teruki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (05) : 809 - 820
  • [29] Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours
    Engelsman, M
    Damen, EMF
    Koken, PW
    van 't Veld, AA
    van Ingen, KM
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) : 299 - 309
  • [30] Measurement of CT Density Model Variations and the Impact On the Accuracy of Monte Carlo (MC) Dose Calculation in Stereotactic Body Radiation Therapy for Lung Cancer
    Xiang, H.
    Li, B.
    Russo, G.
    Behrman, R.
    Lu, H.
    Fernando, H.
    Kachnic, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3460 - 3460