Why liquid membrane extraction is an attractive alternative in sample preparation

被引:44
|
作者
Chimuka, L
Cukrowska, E
Jönsson, JA
机构
[1] Univ Venda Sci & Technol, Sch Environm Sci & Engn, Dept Ecol & Resource Management, ZA-0950 Thohoyandou, Limpopo Prov, South Africa
[2] Univ Witwatersrand, Sch Chem, ZA-2050 Johannesburg, South Africa
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
D O I
10.1351/pac200476040707
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of liquid membrane-based extractions is increasingly seen as offering an alternative to conventional sample preparation procedures in analysis of chemical species in both environmental and biological media. In this article, emphasis is placed on the attractiveness of liquid membrane-based extraction techniques to a variety of analytical applications such as speciation of metal ions in biological fluids, time-weighted average field sampling, and time-weighted average passive field sampling. Further, the area of designing new and much simpler miniaturized configurations, which is enjoying much attention in liquid membrane-based extraction techniques, is discussed.
引用
下载
收藏
页码:707 / 722
页数:16
相关论文
共 50 条
  • [41] METAL EXTRACTION BY LIQUID MEMBRANE
    CAHN, RP
    FRANKENFELD, JW
    LI, NN
    NADEN, D
    SUBRAMANIAN, KN
    JOURNAL OF METALS, 1980, 32 (12): : 49 - 49
  • [42] EMULSIONS FOR LIQUID MEMBRANE EXTRACTION
    YURTOV, EV
    KOROLEVA, MY
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 38 - IEC
  • [43] MODELING OF LIQUID MEMBRANE EXTRACTION
    HO, WS
    LI, NN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 95 - INDE
  • [44] INORGANIC MEMBRANE TECHNOLOGY IN SAMPLE PREPARATION
    HOFFMAN, J
    AMERICAN LABORATORY, 1989, 21 (4A) : 12 - 12
  • [45] Membrane based sample preparation chip
    Morschhauser, A.
    Stiehl, C.
    Grosse, A.
    Nestler, J.
    Otto, T.
    Gessner, T.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 923 - 925
  • [46] WHY DRI HAS BECOME AN ATTRACTIVE ALTERNATIVE TO BLAST-FURNACE OPERATORS
    BECERRA, J
    YANEZ, D
    IRON AND STEEL INTERNATIONAL, 1980, 53 (01): : 43 - &
  • [47] WHY DRI HAS BECOME AN ATTRACTIVE ALTERNATIVE TO BLAST FURNACE OPERATORS.
    Becerra, Jorge
    Yanez, David
    Iron and steel international, 1980, 53 (01): : 43 - 45
  • [48] ALTERNATIVE APPROACHES FOR SAMPLE PREPARATION IN CAPILLARY ELECTROPHORESIS
    Guijt, Rosanne M.
    CECE 2015: 12TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2015, : 34 - 35
  • [49] Development of Alternative Green Sample Preparation Techniques
    Gionfriddo, Emanuela
    SEPARATIONS, 2020, 7 (02)
  • [50] Rectification, liquid/liquid extraction, and membrane technology
    Deibele, L
    Schäfer, JP
    Eltner, A
    CHEMIE INGENIEUR TECHNIK, 2000, 72 (12) : 1487 - +