In silico assessment of the dosimetric quality of a novel, automated radiation treatment planning strategy for linac-based radiosurgery of multiple brain metastases and a comparison with robotic methods

被引:28
|
作者
Slosarek, Krzysztof [1 ]
Bekman, Barbara [1 ]
Wendykier, Jacek [1 ]
Grzadziel, Aleksandra [1 ,2 ]
Fogliata, Antonella [3 ]
Cozzi, Luca [3 ,4 ]
机构
[1] Maria Sklodowska Curie Mem Canc Ctr & Inst Oncol, Dept Radiotherapy Planning, Gliwice, Poland
[2] Univ Silesia, Dept Med Phys, Katowice, Poland
[3] Humanitas Clin & Res Hosp, Radiotherapy & Radiosurg Dept, Rozzano, Italy
[4] Humanitas Univ, Dept Biomed Sci, Rozzano, Italy
关键词
HyperArc; CyberKnife; VMAT; Multiple brain metastases; Radiosurgery; STEREOTACTIC BODY RADIOTHERAPY; PROSTATE-CANCER; THERAPY; FEASIBILITY; RAPIDARC; SBRT;
D O I
10.1186/s13014-018-0997-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery. Methods: A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced HyperArc. For all patients, three treatment plans were computed and compared: i: a HyperArc; ii: a standard VMAT; iii) a CyberKnife. Dosimetric features were computed for the clinical target volumes as well as for the healthy brain tissue and the organs at risk. Results: The data showed that the best dose homogeneity was achieved with the VMAT technique. HyperArc allowed to minimize the volume of brain receiving 4Gy (as well as for the mean dose and the volume receiving 12Gy, although not statistically significant). The smallest dose on 1 cm(3) volume for all organs at risk is for CK techniques, and the biggest for VMAT (p < 0.05). The Radiation Planning Index coefficient indicates that, there are no significant differences among the techniques investigated, suggesting an equivalence among these. Conclusion: At treatment planning level, the study demonstrates that the use of HyperArc technique can significantly improve the sparing of the healthy brain while maintaining a full coverage of the target volumes.
引用
收藏
页数:10
相关论文
共 22 条
  • [21] Initial Experience With Single-Isocenter Radiosurgery to Target Multiple Brain Metastases Using an Automated Treatment Planning Software: Clinical Outcomes and Optimal Target Volume Margins Strategy
    Minniti, Giuseppe
    Capone, Luca
    Alongi, Filippo
    Figlia, Vanessa
    Nardiello, Barbara
    El Gawhary, Randa
    Scaringi, Claudia
    Bianciardi, Federico
    Tolu, Barbara
    Gentile, Piercarlo
    Paolini, Sergio
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (05) : 856 - 864
  • [22] Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques
    Prentou, Georgia
    Pappas, Eleftherios P.
    Logothetis, Andreas
    Koutsouveli, Efi
    Pantelis, Evaggelos
    Papagiannis, Panagiotis
    Karaiskos, Pantelis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (03): : 32 - 44