Release characteristics and control of hydrogen sulfide during thermal drying of municipal wastewater sludge

被引:9
|
作者
Wu, Min [1 ]
Wang, Zhiyuan [1 ]
Zhou, Jie [2 ]
Niu, Mingxing [1 ]
Jiang, Xiaolin [3 ]
Lv, Yaoling [4 ]
Xiao, Qianqian [1 ]
Li, Gongxia [1 ]
Wang, Yayi [1 ]
机构
[1] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resources Reuse, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Tongji Architectural Design Grp Corp Ltd, 1230 Siping Rd, Shanghai 200092, Peoples R China
[3] Shanghai Pudong Veolia Water Corp Ltd, 840 Pudong Ave, Shanghai 200120, Peoples R China
[4] Shanghai Urban Construct Design & Res Inst, 3447 Dongfang Rd, Shanghai 200120, Peoples R China
关键词
Sludge treatment; Thermal drying; Odor; Hydrogen sulfide; CONTAINING ODOROUS COMPOUNDS; SULFUR-CONTAINING GASES; SEWAGE-SLUDGE; EMISSION CHARACTERISTICS; COAL PYROLYSIS; CURRENT STATE; NITROGEN; STABILIZATION; DISPOSAL; CHINA;
D O I
10.1007/s10163-017-0657-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hydrogen sulfide (H2S) is the most predominant malodorous gas released during the thermal drying of municipal wastewater sludge. Experiment using a laboratory-scale tube furnace was conducted to determine the characteristics of H2S release and the changes of sludge moisture content. The addition of calcium oxide (CaO) in the original sludge was also tested and evaluated for its inhibitory effect on the H2S release. The results showed that the amount of H2S released increases with the increase of temperature in the tested range of temperature from 80 to 280 A degrees C. The critical temperature range defined as the turn point of temperature at which the H2S or other odorous gases release starts to drastically increase was determined to be 200-240 A degrees C. It was found that the drying process could be divided into two stages according to the changes of H2S release speed and the corresponding moisture content, and the majority of H2S release was detected in the second stage. The reduction of element sulfur in sludge was approximately proportional to the H2S released in the temperature range from 80 to 280 A degrees C. The addition of CaO in the sludge could significantly repress the release of H2S during thermal drying. This inhibitory effect was observed to last for the entire drying process and not be changed with the change of temperature.
引用
收藏
页码:946 / 954
页数:9
相关论文
共 50 条
  • [31] Thermal drying of wastewater sludge: Change in drying area owing to volume shrinkage and crack development
    Tao, T
    Peng, XF
    Lee, DJ
    DRYING TECHNOLOGY, 2005, 23 (03) : 669 - 682
  • [32] Hazardous emission from thermal drying of municipal sludge and industrial sludge as well as associated odor pollution
    Bao, Bike
    Wang, Fei
    JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2023, 25 (04) : 2187 - 2194
  • [33] Hazardous emission from thermal drying of municipal sludge and industrial sludge as well as associated odor pollution
    Bike Bao
    Fei Wang
    Journal of Material Cycles and Waste Management, 2023, 25 : 2187 - 2194
  • [34] Effects of thermal hydrolysis temperature on physical characteristics of municipal sludge
    Feng, Guohong
    Guo, Yabing
    Tan, Wei
    WATER SCIENCE AND TECHNOLOGY, 2015, 72 (11) : 2018 - 2026
  • [35] Anaerobic stabilisation of sludge produced during municipal wastewater treatment by electrocoagulation
    Hutnan, M
    Drtil, M
    Kalina, A
    JOURNAL OF HAZARDOUS MATERIALS, 2006, 131 (1-3) : 163 - 169
  • [36] Adhesion and Cohesion Characteristics of Sewage Sludge During Drying
    Li, B.
    Wang, F.
    Chi, Y.
    Yan, J. H.
    DRYING TECHNOLOGY, 2014, 32 (13) : 1598 - 1607
  • [37] Assessment on thermal behavior of municipal sewage sludge thin-layer during hot air forced convective drying
    Huang, Y. W.
    Chen, M. Q.
    Jia, L.
    APPLIED THERMAL ENGINEERING, 2016, 96 : 209 - 216
  • [38] Exposure to dust, endotoxin and airborne microorganisms in wastewater sludge thermal drying units
    Schlosser, O.
    Huyard, A.
    Catalan, V.
    WATER SCIENCE AND TECHNOLOGY, 2011, 64 (05) : 1073 - 1080
  • [39] Characteristics of reject waters and condensates generated during drying of sewage sludge from selected wastewater treatment plants
    Karwowska, Beata
    Sperczynska, Elzbieta
    Wisniowska, Ewa
    DESALINATION AND WATER TREATMENT, 2016, 57 (03) : 1176 - 1183
  • [40] Hygienization of municipal sludge in automatically operated chamber filter presses with thermal vacuum drying
    Sagberg, P
    WATER SCIENCE AND TECHNOLOGY, 2004, 50 (07) : 53 - 60