Biliary Anatomy on 3D MRCP: Comparison of Volume-Rendering and Maximum-Intensity-Projection Algorithms

被引:10
|
作者
Morita, Satoru [1 ,2 ]
Saito, Naoko [2 ]
Suzuki, Kazufumi [2 ]
Mitsuhashi, Norio [2 ]
机构
[1] Saiseikai Kurihashi Hosp, Dept Radiol, Kurihashi, Saitama 3491105, Japan
[2] Tokyo Womens Med Univ, Dept Radiol, Tokyo, Japan
关键词
magnetic resonance imaging; MRCP; PACE; volume; cystic duct; TURBO SPIN-ECHO; MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; PROSPECTIVE ACQUISITION CORRECTION; HELICAL CT CHOLANGIOGRAPHY; LAPAROSCOPIC CHOLECYSTECTOMY; INITIAL-EXPERIENCE; LIVER-DONORS; BILE-DUCTS; ANGIOGRAPHY; TRANSPLANTATION;
D O I
10.1002/jmri.21398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare Volume-rendering (VR) and maximum-intensity-projection (MIP) of three-dimensional T2-weighted turbo spin-echo magnetic resonance cholangio-pancreatography using a free-breathing navigator-triggered prospective acquisition correction (3D-TSE-PACE-MRCP) to define biliary anatomies. Materials and Methods: VR and MIP images of 3D-TSE-PACE-MRCP for 102 patients were retrospectively evaluated. Interpretation of cystic duct variation and biliary branching patterns of each image were recorded independently by two radiologists in a blinded fashion. Interpretation confidence on a five-point scale was compared using the Wilcoxon signed-rank test. The McNemar test was use to compare the accuracies of each reformation with the reference standard obtained by consensus interpretation of both the images and source images. Results: The reference standard identified all biliary bifurcations and 95 of 102 cystic duct confluences (93. 1%). VR findings agreed with the reference standard findings more often than MIP with regard to cystic duct variation (94 [92.2%] vs. 76 [74.5%], P < 0.01) while there was no significant difference for biliary branching patterns (99 [97. 1%] vs. 92 [90.2%], P = 0.092). The mean confidence score was significantly higher with VR than MIP with regard to both cystic duct variation and biliary branching patterns (3.7 vs. 2.4; P < 0.01; 4.1 vs. 3.3: P < 0.01). Conclusion: VR reformation of 3D-TSE-PACE-MRCP defines biliary anatomies more accurately than MIP.
引用
下载
收藏
页码:601 / 606
页数:6
相关论文
共 50 条
  • [31] 3D Vascular Segmentation Supervised by 2D Annotation of Maximum Intensity Projection
    Guo, Zhanqiang
    Tan, Zimeng
    Feng, Jianjiang
    Zhou, Jie
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (06) : 2241 - 2253
  • [32] EVALUATION OF THE RENAL-ARTERIES IN KIDNEY DONORS - VALUE OF 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY WITH MAXIMUM-INTENSITY-PROJECTION OR SURFACE RENDERING
    MEYERS, SP
    TALAGALA, SL
    TOTTERMAN, S
    AZODO, MVU
    KWOK, E
    SHAPIRO, L
    SHAPIRO, R
    PABICO, RC
    APPLEGATE, GR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) : 117 - 121
  • [33] Comparison of 3D sensing algorithms for single shot fringe projection profilometry
    Dhanotia, Jitendra
    Chatterjee, Amit
    Bhatia, Vimal
    Prakash, Shashi
    2018 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND PHOTONICS (ICMAP), 2018,
  • [34] Left adrenal vein localization by 3D real-time volume-rendering CTA before laparoscopic nephrectomy in living renal donors
    Scatarige, JC
    Horton, KM
    Ratner, LE
    Fishman, EK
    ABDOMINAL IMAGING, 2001, 26 (05): : 553 - 556
  • [35] Precision Mapping of Intrahepatic Biliary Anatomy and Its Anatomical Variants Having a Normal Liver Using 2D and 3D MRCP
    Mazroua, Jehan A.
    Almalki, Yassir Edrees
    Alaa, Mohamed
    Alduraibi, Sharifa Khalid
    Aboualkheir, Mervat
    Aldhilan, Asim S.
    Almushayti, Ziyad A.
    Aly, Sameh Abdelaziz
    Basha, Mohammad Abd Alkhalik
    DIAGNOSTICS, 2023, 13 (04)
  • [36] Left adrenal vein localization by 3D real-time volume-rendering CTA before laparoscopic nephrectomy in living renal donors
    J. C. Scatarige
    K. M. Horton
    L. E. Ratner
    E. K. Fishman
    Abdominal Imaging, 2001, 26 : 553 - 556
  • [37] Image Processing Method for 3D Volume Rendering from One 2D Projection: Application to Cancer Spheroids
    Piccinini, Filippo
    Tesei, Anna
    Zoli, Wainer
    Bevilacqua, Alessandro
    2014 4TH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING THEORY, TOOLS AND APPLICATIONS (IPTA), 2014, : 105 - 110
  • [38] Volume Rendering Method Applied to 3D Edge Impurity Emission in LHD to Produce Projection Image in Arbitrary Plane
    Tamura, Yuichi
    Kobayashi, Masahiro
    Kobayashi, Taisuke
    Omori, Wataru
    Nakamura, Hiroaki
    Ohtani, Hiroaki
    Fujiwara, Susumu
    PLASMA AND FUSION RESEARCH, 2019, 14
  • [39] Volume rendering method applied to 3D edge impurity emission in LHD to produce projection image in arbitrary plane
    Tamura Y.
    Kobayashi M.
    Kobayashi T.
    Omori W.
    Nakamura H.
    Ohtani H.
    Fujiwara S.
    The LHD Experimental Group
    Plasma and Fusion Research, 2019, 14
  • [40] Pancreaticoduodenal arcades and dorsal pancreatic artery: Comparison of CT angiography with three-dimensional volume rendering, maximum intensity projection, and shaded-surface display
    Hong, KC
    Freeny, PC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) : 925 - 931