T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity-corrected variable flip angle method

被引:45
|
作者
Kim, Ji Eun [1 ]
Kim, Hyun Ok [2 ]
Bae, Kyungsoo [1 ]
Choi, Dae Seob [1 ]
Nickel, Dominik [3 ]
机构
[1] Gyeongsang Natl Univ, Coll Med, Dept Radiol, Jinju, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Internal Med, 79 Gangnam Ro, Jinju 52727, South Korea
[3] Siemens Healthineers, Erlangen, Germany
关键词
Liver; Magnetic resonance imaging; Gadoxetic acid; Cirrhosis; RELAXATION-TIME INDEX; QUANTITATIVE-EVALUATION; HEPATITIS-C; FIBROSIS; T-1; QUANTIFICATION; ELASTOGRAPHY; TRANSPORTER; EXPRESSION; PARAMETERS;
D O I
10.1007/s00330-018-5947-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo compare look-locker inversion recovery (LLIR) and B-1 inhomogeneity-corrected variable flip angle T1 mapping methods for estimation of liver function and prediction of hepatic insufficiency and decompensation on gadoxetic acid-enhanced MR imaging.MethodsIn this retrospective study, 248 patients with normal liver function, chronic liver disease, or cirrhosis underwent gadoxetic acid-enhanced liver MR imaging, including T1 mapping at 10-min and 20-min hepatobiliary phase (HBP) by using both methods. T1 relaxation times of the liver (T1(Liver-pre), T1(Liver-post)) and the spleen (T1(Spleen)) were correlated between two methods. T1(Liver) ([T1(Liver-pre) - T1(Liver-post)]/T1(Liver-pre)), adjusted T1(Liver) ([T1(Spleen) - T1(Liver-post)]/T1(Spleen)), and functional liver volume-to-weight ratio (liver volume on volumetric T1 map/[T1(Liver-post) x patient's weight]) were calculated. The diagnostic performance of T1 parameters and the predictive performance of models (serum marker, serum marker plus T1 parameter) were compared.ResultsT1(Liver-post) showed a strong correlation (r=0.93, p<0.001) between two methods but was significantly different. For depicting cirrhosis, LLIR-adjusted T1(Liver) at 10-min HBP showed the highest performance (p<0.025). For predicting hepatic insufficiency and decompensation, LLIR-adjusted T1(Liver) (Akaike information criterion (AIC), 58.37; C-index, 0.867) and LLIR-T1(Liver-post) (AIC, 48.82; C-index, 0.885) at 10-min HBP showed the best performance, respectively, when added to serum albumin level.ConclusionsT1(Liver-post) showed a strong correlation between two methods but with significant differences. T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1(Liver) and T1(Liver-post) may be the best approach for estimation of liver function and prediction of hepatic insufficiency and decompensation.Key Points center dot T1(Liver-post)showed a strong correlation between LLIR and B(1)inhomogeneity-corrected VFA methods, both at 10-min and 20-min HBP but with significant differences.center dot T1(Liver-post)at 10-min and 20-min HBP using LLIR and B(1)inhomogeneity-corrected VFA methods could not be used interchangeably during the follow-up in patients with chronic liver disease (CLD) or cirrhosis.center dot T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1(Liver)and T1(Liver-post)may be the most suitable method and parameter for estimation of global liver function and prediction of clinical outcomes in patients with CLD or cirrhosis.
引用
收藏
页码:3584 / 3594
页数:11
相关论文
共 40 条
  • [31] 3D variable flip angle T1 mapping for differentiating benign and malignant liver lesions at 3T: comparison with diffusion weighted imaging
    Fei Wang
    Qing Yang
    Yupei Zhang
    Jun Liu
    Mengxiao Liu
    Juan Zhu
    BMC Medical Imaging, 22
  • [32] 3D variable flip angle T1 mapping for differentiating benign and malignant liver lesions at 3T: comparison with diffusion weighted imaging
    Wang, Fei
    Yang, Qing
    Zhang, Yupei
    Liu, Jun
    Liu, Mengxiao
    Zhu, Juan
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [33] Variable Flip Angle-Based Fast Three-Dimensional T1 Mapping for Delayed Gadolinium-Enhanced MRI of Cartilage of the Knee: Need for B1 Correction
    Manuel, Angela
    Li, Wei
    Jellus, Vladimir
    Hughes, Timothy
    Prasad, Pottumarthi V.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1377 - 1383
  • [34] Evaluation of Nonscarred Myocardial T1 Value Using Contrast-Enhanced Look-Locker Cardiac MRI and Its Relationship to Cardiac Function in Dilated Cardiomyopathy: Comparison of 1.5 and 3.0 Tesla MRI
    Tachi, Masaki
    Amano, Yasuo
    Kobayashi, Yasuhiro
    Mizuno, Kyoichi
    Kumita, Shinichiro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1395 - 1401
  • [35] Liver Biliary Function Evaluation on a 1.5T Magnetic Resonance Imaging Scan by T1 Reduction Rate Assessment Using Variable-Flip-Angle Sequences
    Di Stasio, Marco
    Cordopatri, Cesare
    Nardi, Cosimo
    Busoni, Simone
    Noferini, Linhsia
    Colagrande, Stefano
    Calistri, Linda
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (03) : 354 - 360
  • [36] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ying Ding
    Sheng-Xiang Rao
    Caizhong Chen
    Renchen Li
    Meng-Su Zeng
    European Radiology, 2015, 25 : 1392 - 1398
  • [37] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ding, Ying
    Rao, Sheng-Xiang
    Chen, Caizhong
    Li, Renchen
    Zeng, Meng-Su
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1392 - 1398
  • [38] Staging liver fibrosis in chronic hepatitis B with T1 relaxation time index on gadoxetic acid-enhanced MRI: Comparison with aspartate aminotransferase-to-platelet ratio index and FIB-4
    Yang, Li
    Ding, Ying
    Rao, Shengxiang
    Chen, Caizhong
    Wu, Lifang
    Sheng, Ruofan
    Fu, Caixia
    Zeng, Mengsu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 1186 - 1194
  • [39] Predicting post-hepatectomy liver failure with T1 mapping-based whole-liver histogram analysis on gadoxetic acid-enhanced MRI: comparison with the indocyanine green clearance test and albumin-bilirubin scoring system
    Li, Jun
    Li, Yi
    Chen, Yuan-Yuan
    Wang, Xiao-Ying
    Fu, Cai-Xia
    Grimm, Robert
    Ding, Ying
    Zeng, Meng-Su
    EUROPEAN RADIOLOGY, 2024,
  • [40] Assessment of biliary anatomy in potential living liver donors: Added value of gadoxetic acid-enhanced T1 MR Cholangiography (MRC) including utilization of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique in comparison to T2W-MRC
    Guimaraes, Luis
    Jandaghi, Ali Babaei
    Menezes, Ravi
    Grant, David
    Cattral, Mark
    Jhaveri, Kartik S.
    MAGNETIC RESONANCE IMAGING, 2020, 70 : 64 - 72