Norovirus detection in water samples at the level of single virus copies per microliter using a smartphone-based fluorescence microscope

被引:55
|
作者
Chung, Soo [1 ,5 ]
Breshears, Lane E. [2 ]
Gonzales, Alana [2 ]
Jennings, Christian M. [2 ]
Morrison, Christina M. [3 ]
Betancourt, Walter Q. [3 ]
Reynolds, Kelly A. [4 ]
Yoon, Jeong-Yeol [1 ,2 ]
机构
[1] Univ Arizona, Dept Biosyst Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[3] Univ Arizona, Dept Environm Sci, Tucson, AZ USA
[4] Univ Arizona, Mel & Enid Zuckerman Coll Publ Hlth, Tucson, AZ USA
[5] ARS, USDA, Richard Russell Res Ctr, Athens, GA USA
基金
美国国家科学基金会;
关键词
D O I
10.1038/s41596-020-00460-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Norovirus is a widespread public health threat and has a very low infectious dose. This protocol presents the extremely sensitive mobile detection of norovirus from water samples using a custom-built smartphone-based fluorescence microscope and a paper microfluidic chip. Antibody-conjugated fluorescent particles are immunoagglutinated and spread over the paper microfluidic chip by capillary action for individual counting using a smartphone-based fluorescence microscope. Smartphone images are analyzed using intensity- and size-based thresholding for the elimination of background noise and autofluorescence as well as for the isolation of immunoagglutinated particles. The resulting pixel counts of particles are correlated with the norovirus concentration of the tested sample. This protocol provides detailed guidelines for the construction and optimization of the smartphone- and paper-based assay. In addition, a 3D-printed enclosure is presented to incorporate all components in a dark environment. On-chip concentration and the assay of higher concentrations are presented to further broaden the assay range. This method is the first to be presented as a highly sensitive mobile platform for norovirus detection using low-cost materials. With all materials and reagents prepared, a single standard assay takes under 20 min. Although the method described is used for detection of norovirus, the same protocol could be adapted for detection of other pathogens by using different antibodies.
引用
收藏
页码:1452 / 1475
页数:24
相关论文
共 49 条
  • [41] Analysis of polyaromatic hydrocarbons in water samples, at ppt level, using on-line solid phase extraction-reversed phase liquid chromatography fluorescence detection
    Medvedovici, AV
    David, V
    David, F
    Sandra, P
    CHEMIA ANALITYCZNA, 1998, 43 (01): : 47 - 56
  • [42] Detection of fluoride ions using carbon quantum dots derived from coal washery rejects via an on-off-on fluorescence mechanism: a smartphone-based image-processing and machine learning approach
    Boruah, Anusuya
    Rajbonshi, Akhil
    Roy, Kallol
    Saikia, Binoy K.
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (09) : 3862 - 3876
  • [43] Analysis of poliaromatic hydrocarbons in water samples, at ppt level, using on-line solid phase extraction-reversed phase liquid chromatography-fluorescence detection
    Medvedovici, A. V.
    David, V.
    David, F.
    Sandra, P.
    Chemia Analityczna, 43 (01):
  • [44] Highly selective simultaneous electrochemical detection of trace level of heavy metals in water samples based on the single-crystalline Co3O4 nanocubes modified electrode
    Yamuna, Annamalai
    Hong, Cheng-Yu
    Chen, Shen-Ming
    Chen, Tse-Wei
    Alabdullkarem, Eman A.
    Soylak, Mustafa
    AL-Anazy, Murefah Mana
    Ali, Mohammad Ajmal
    Liu, Xiaoheng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 887
  • [45] A surfactant-based quasi-hydrophobic deep eutectic solvent for dispersive liquid-liquid microextraction of gliflozins from environmental water samples using UHPLC/fluorescence detection
    Rageh, Azza H.
    Abdel-aal, Fatma A. M.
    Farrag, Sherien A.
    Ali, Al-Montaser Bellah H.
    TALANTA, 2024, 266
  • [46] Fluorescence Detection of H5N1 Virus Gene Sequences Based on Optical Tweezers with Two-Photon Excitation Using a Single Near Infrared Nanosecond Pulse Laser
    Li, Cheng-Yu
    Cao, Di
    Kang, Ya-Feng
    Lin, Yi
    Cui, Ran
    Pang, Dai-Wen
    Tang, Hong-Wu
    ANALYTICAL CHEMISTRY, 2016, 88 (08) : 4432 - 4439
  • [47] Part-per-trillion level SF6 detection using a quartz enhanced photoacoustic spectroscopy-based sensor with single-mode fiber-coupled quantum cascade laser excitation
    Spagnolo, Vincenzo
    Patimisco, Pietro
    Borri, Simone
    Scamarcio, Gaetano
    Bernacki, Bruce E.
    Kriesel, Jason
    OPTICS LETTERS, 2012, 37 (21) : 4461 - 4463
  • [48] Method for detection of epsilon-secondary structure in the precore region of human hepatitis B virus DNA using a fluorescence-based polymerase chain reaction single-strand-conformation polymorphism technique with capillary electrophoresis
    Katsuragi, K
    Kitagishi, K
    Mizuguchi, T
    Nagashima, T
    Kinoshita, M
    Kumada, H
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 307 - 314
  • [49] ZnCo2O4 2 O 4 porous nanosheets-based sensing platform for ultra-sensitive detection of Pb(II) ion at sub-parts-per-trillion level in juice and beverage samples by using differential pulse anodic stripping voltammetry
    Nguyen Ngoc Huyen
    Ngo Xuan Dinh
    Hoang Van Thanh
    Pham Duc Thang
    Anh-Tuan Le
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 134