Quantitative determination of polyethylene glycol with modified Dragendorff reagent method

被引:54
|
作者
Jia, Zhiqian [1 ]
Tian, Chunai [1 ]
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
基金
中国国家自然科学基金; 芬兰科学院;
关键词
Polyethylene glycol; Dragendorff reagent; Ultrafiltration membrane; Molecular weight cut-off; PERFORMANCE; MEMBRANE;
D O I
10.1016/j.desal.2008.09.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Quantitative determination of polyethylene glycol (PEG) is usually needed in membrane technology, water environment and chromatography. The concentration of PEG is generally measured with the Dragendorff reagent. But in the literature method, the hydrolysis of the Dragendorff reagent results in nonlinear calibration curve and unsatisfied reproducibility. In this paper, a modified Dragendorff approach was provided to inhibit the hydrolysis in the analysis. The effects of acids and its concentrations were studied. The results showed that, with the modified method, the calibration curves for PEG 4000, 6000, 10,000 and 20,000 displayed good linearity.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 50 条
  • [31] MODIFIED ULTRAVIOLET SPECTROPHOTOMETRIC METHOD FOR QUANTITATIVE DETERMINATION OF BARBITURATES
    GOULD, TC
    MAYO, EL
    BOWMAN, KP
    FEDERATION PROCEEDINGS, 1949, 8 (01) : 295 - 295
  • [32] QUANTITATIVE DETERMINATION OF FIBRINOGEN IN PLASMA GRAMS METHOD MODIFIED
    BANG, HO
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1957, 9 (02): : 205 - 207
  • [33] NOTE ON A MODIFIED METHOD FOR THE QUANTITATIVE-DETERMINATION OF STARCH
    FLEMING, SE
    REICHERT, RD
    CEREAL CHEMISTRY, 1980, 57 (02) : 153 - 154
  • [34] EVALUATION OF A NEW REAGENT FOR COVALENT ATTACHMENT OF POLYETHYLENE-GLYCOL TO PROTEINS
    ZALIPSKY, S
    SELTZER, R
    MENONRUDOLPH, S
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1992, 15 (01) : 100 - 114
  • [35] Properties of bitumen modified by polyethylene and polyethylene glycol with different molecular weights
    Xia, Tian
    Chen, Xiang
    Xu, Jianhui
    Chen, Wenqiang
    Huang, Xinyue
    Li, Youbing
    INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2022, 23 (11) : 3941 - 3948
  • [36] DPPH AS REAGENT FOR QUANTITATIVE DETERMINATION OF HYDROPEROXIDES
    TARLADGIS, BG
    SCHOENMA.AW
    BEGEMANN, PH
    JOURNAL OF DAIRY SCIENCE, 1964, 47 (06) : 678 - &
  • [37] QUANTITATIVE DETERMINATION OF PIPERINE WITH LABAT REAGENT
    GRAHAM, HD
    NATURE, 1965, 207 (4996) : 526 - &
  • [38] DETERMINATION OF ACETALDEHYDE IN POLYETHYLENE-GLYCOL TEREPHTHALATE
    KANCHIKU, Y
    OHSUGA, N
    BUNSEKI KAGAKU, 1979, 28 (08) : 508 - 510
  • [39] NEPHELOMETRIC DETERMINATION OF POLYETHYLENE-GLYCOL PROFILES
    COPPOCK, JS
    SCOTT, DL
    LUNEC, J
    ROBINSON, M
    BACON, PA
    BRITISH JOURNAL OF RHEUMATOLOGY, 1985, 24 (01): : 82 - 82
  • [40] EVALUATION OF TURBIDIMETRIC DETERMINATION OF POLYETHYLENE-GLYCOL
    RUSSELL, RW
    MCGILLIARD, AD
    BERGER, PJ
    YOUNG, JW
    JOURNAL OF DAIRY SCIENCE, 1982, 65 (09) : 1798 - 1803