Trabecular architecture during the healing process of a tibial diaphysis defect

被引:9
|
作者
Martinez-Zelaya, Victor R. [1 ,2 ]
Archilha, Nathaly L. [1 ]
Calasans-Maia, Monica [3 ]
Farina, Marcos [4 ]
Rossi, Alexandre M. [2 ]
机构
[1] Brazilian Ctr Res Energy & Mat CNPEM, Brazilian Synchrotron Light Lab LNLS, BR-13083970 Campinas, SP, Brazil
[2] Brazilian Ctr Res Phys, Dept Condensed Matter Appl Phys & Nanosci, BR-22290180 Rio De Janeiro, RJ, Brazil
[3] Fluminense Fed Univ, Oral Surg Dept, BR-24020140 Niteroi, RJ, Brazil
[4] Univ Fed Rio de Janeiro, Inst Biomed Sci, BR-21941902 Rio De Janeiro, RJ, Brazil
关键词
MINERALIZED COLLAGEN FIBRILS; BONE ARCHITECTURE; TISSUE; TENSEGRITY; MICROSPHERES; REPAIR; MODEL;
D O I
10.1016/j.actbio.2020.08.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The adaptation of trabecular bone microstructure to mechanical loads has been intensively investigated. However, loading-unrelated aspects of trabecular architecture remain unclear. We used synchrotron radiation-based X-ray microtomography to study the 3D microarchitecture of newly formed trabecular tissue in a defect produced in the cortical region of the rat tibia diaphysis, in the absence (7, 14, and 21 days) or the presence (21 days) of carbonated hydroxyapatite/alginate (cHA) microspheres. This work provides the first evidence that the woven bone trabecular network, formed during the healing process, displays a well-organized 3D microarchitecture consisting of nodes with 3 (3-N), 4 (4-N) and 5 (5-N) connecting trabeculae, with a mean relative abundance of (3-N)/(4-N)/(5-N) = 66/24/7, for the analyzed periods. The measured inter-trabecular angles (ITA) distribution presented a Gaussian profile, with mean value at 115 degrees for 3-N nodes, and 105 degrees for 4-N nodes, close to the angles of idealized 3D regular structures (120 degrees and 109.5 degrees, respectively). Changes in the dispersion of ITA distribution suggested that a highly symmetric trabecular fabric organized under tensegrity principles is formed early during the bone healing process. Post-implantation, cHA disaggregated into multiple fragments (similar to 20-400 mu m), stimulating osteoconduction and bone growth toward the interior of the medullary cavity. The presence of biomaterials in bone defects affected the trabecular dimensions; however, it did not interfere with the formation of geometrical motifs with topological parameters similar to those found in the sham-defects. Statement of Significance The trabecular bone microstructure enables the tissue to meet the necessary mechanical and functional demands. However, the process of trabecular microarchitecture formation during healing, in the absence or presence of a bone graft, is not yet well understood. This work demonstrated that, from the beginning of its formation in cortical bone defects, the woven-bone trabecular network is spatially organized according to the principle of tensegrity. This microarchitecture is comprised of highly symmetric geometric motifs and is an intrinsic characteristic of trabecular growth, regardless of hierarchical scale or mechanical stimulation. The addition of a biodegradable nanostructured calcium phosphate graft did not disrupt trabecular microarchitecture; however, graft biodegradation should be controlled to optimize the reproduction of intrinsic trabecular motifs throughout the defect. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd.
引用
收藏
页码:181 / 193
页数:13
相关论文
共 50 条
  • [21] Stabilization of an inserted tricalcium phosphate spacer enhances the healing of a segmental tibial defect in sheep
    Gao T.-J.
    Lindholm T.S.
    Kommonen B.
    Ragni P.
    Paronzini A.
    Lindholm T.C.
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 (5) : 290 - 294
  • [22] SCLEROSTIN NEUTRALISING ANTIBODY ENHANCES HEALING OF TIBIAL METAPHYSEAL DEFECT IN AN OVX RAT MODEL
    McDonald, Michelle
    Morse, Alyson
    Peacock, Lauren
    Mikulec, Kathy
    Baldock, Paul
    Liu, Min
    Ke, Hua Zhu David
    Little, David
    BONE, 2010, 46 : S25 - S25
  • [23] HEALING-PROCESS OF TIBIAL FRACTURE - VIEW BY MEASUREMENT OF ULTRASOUND ABSORPTION
    HULLER, C
    GAY, B
    EBERT, T
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1983, 125 (04): : 71 - 72
  • [24] THE EFFECT OF ELECTROACUPUNCTURE ON HEALING PROCESS OF TIBIAL BONE AFTER OSTEOTOMY IN RATS
    Nakajima, Miwa
    Inoue, Motohiro
    Hojo, Tatsuya
    Takatori, Ryota
    Inoue, Nozomu
    Itoi, Megumi
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2009, 59 : 274 - 274
  • [25] The pattern of change during human tibial trabecular bone ontogeny and locomotor development: components of intra-tibial heterogeneity
    Gosman, J. H.
    Ketcham, R. A.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2009, : 137 - 137
  • [26] Comparison of Radiographic Outcomes Assessed via the Radiographic Union Scale for Tibial Fractures and Alkaline Phosphatase Levels during the Tibial Healing Process: A Series of Case Reports
    Ninomiya, Andre Felipe
    Bertolucci, Vanessa
    Kaneko, Luisa Oliveira
    Nonose, Nilson
    Abreu, Luiza di Loreto
    Harfuch, Gabriel Rodrigues
    dos Reis, Ivan Gustavo Masselli
    Scariot, Pedro Paulo Menezes
    Messias, Leonardo Henrique Dalcheco
    BIOLOGY-BASEL, 2024, 13 (06):
  • [27] HISTOMORPHOMETRIC STUDY OF TRABECULAR BONE REMODELING DURING CONDYLAR PROCESS FRACTURE-HEALING IN THE GROWING PERIOD - EXPERIMENTAL-STUDY
    YASUOKA, T
    OKA, N
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (09) : 981 - 988
  • [28] SYSTEMIC PTH RELEASE DURING EXERCISE ENHANCES TRABECULAR BONE ARCHITECTURE
    Gardinier, Joseph D.
    Mohamed, Fatma
    Kohn, David H.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [29] MECHANICAL FORCES AS PREDICTORS OF HEALING DURING TIBIAL LENGTHENING BY DISTRACTION OSTEOGENESIS
    ARONSON, J
    HARP, JH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (301) : 73 - 79
  • [30] DOES BISPHOSPHONATE TREATMENT ALTER THE HEALING OF BONE DEFECT WHEN ADMINISTERED AT INITIATION OF THE HEALING PROCESS?
    Lavet, C.
    Rizzoli, R.
    Ammann, P.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : S121 - S121