Evaluation of B10Plus+* Proportional Detectors for Neutron Coincidence Counting

被引:0
|
作者
Yoon, S. [1 ]
Beddingfield, D. H. [1 ]
机构
[1] IAEA, Dept Safeguards, Vienna, Austria
来源
2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA) | 2015年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the BRIPlus+w proportional counter. The detector design is intended to serve as a costeffective alternative to traditional He-3 proportional counters in a variety of applications. The detector is a hybrid design B-10-lined tube optimized with the addition of a small quantity of He-3 gas to improve the detector performance and efficiency. As a demonstration of the BIOPlus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B10Plus+ proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Scalable 10B Powder Backfilling Process for Large-Area High-Efficiency Microstructured Thermal Neutron Detectors
    Shamsi, Zeshaan H.
    Rodriguez-Davila, Rodolfo
    Fernandez-Izquierdo, Leunam
    Caraveo-Frescas, Jesus A.
    Quevedo, Manuel
    ACS APPLIED ENGINEERING MATERIALS, 2023, 1 (06): : 1676 - 1683
  • [32] Evaluation of the dose enhancement of combined 10B+157Gd neutron capture therapy (NCT)
    Protti, N.
    Geninatti-Crich, S.
    Alberti, D.
    Lanzardo, S.
    Deagostino, A.
    Toppino, A.
    Aime, S.
    Ballarini, F.
    Bortolussi, S.
    Bruschi, P.
    Postuma, I.
    Altieri, S.
    Nikjoo, H.
    RADIATION PROTECTION DOSIMETRY, 2015, 166 (1-4) : 369 - 373
  • [33] Study of Boron Coated Straws and mixed (10B/3He) detectors for passive neutron measurements of radioactive waste drums
    Eleon, Cyrille
    Battiston, Florian
    Bounaud, Maxime
    Ben Mosbah, Mehdi
    Passard, Christian
    Perot, Bertrand
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [34] Neutron sensitivity of 10B4C-coated aluminum honeycomb using a single-anode wire, P-10 continuous-gas-flow proportional counter
    Edwards, Nathaniel S.
    Nelson, Kyle A.
    Hinson, Niklas J.
    Tiner, Christopher N.
    Reichenberger, Michael A.
    Fronk, Ryan G.
    McGregor, Douglas S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 85 - 89
  • [35] Toward Mega-pixel Neutron Imager Using Current-Biased Kinetic Inductance Detectors of Nb Nanowires with 10B Converter
    Ishida, Takekazu
    Yoshioka, Naohito
    Narukami, Yoshito
    Shishido, Hiroaki
    Miyajima, Shigeyuki
    Fujimaki, Akira
    Miki, Shigehito
    Wang, Zhen
    Hidaka, Mutsuo
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 216 - 221
  • [36] Evaluation of hypoxia-specific cytotoxic bioreductive agent-sodium borocaptate- 10B conjugates as 10B-carriers in boron neutron capture therapy
    Masunaga S.-I.
    Nagasawa H.
    Gotoh K.
    Sakurai Y.
    Uto Y.
    Hori H.
    Nagata K.
    Suzuki M.
    Maruhashi A.
    Kinashi Y.
    Ono K.
    Radiation Medicine, 2006, 24 (2): : 98 - 107
  • [37] Neutron Detection Sensitivity and H*10 Dosimetry Tensioned Metastable Fluid Detectors vs He-3 (Ludlum 42-49B) and ROSPEC
    Ozerov, S.
    Boyle, N.
    Harabagiu, C.
    DiPrete, D.
    Whiteside, T.
    Boone, A.
    Hadlock, D.
    Noll, W.
    Roberts, D.
    Taleyarkhan, R. P.
    HEALTH PHYSICS, 2023, 125 (01): : 58 - 59
  • [38] The effect of incremental gamma-ray doses and incremental neutron fluences upon the performance of self-biased 10B-coated high-purity epitaxial GaAs thermal neutron detectors
    Gersch, HK
    McGregor, DS
    Simpson, PA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 85 - 98
  • [39] Evaluation of the performance of a fibre-coded neutron detector with a ZnS/10B2O3 ceramic scintillator
    Nakamura, T.
    Schooneveld, E. M.
    Rhodes, N. J.
    Katagiri, M.
    Sakasai, K.
    Soyama, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (01): : 164 - 166
  • [40] Natural Boron and 10B-Enriched Hexagonal Boron Nitride for High-Sensitivity Self-Biased Metal-Semiconductor-Metal Neutron Detectors
    Mballo, Adama
    Ahaitouf, Ali
    Sundaram, Suresh
    Srivastava, Ashutosh
    Ottapilakkal, Vishnu
    Gujrati, Rajat
    Phuong Vuong
    Karrakchou, Soufiane
    Kumar, Mritunjay
    Li, Xiaohang
    Halfaya, Yacine
    Gautier, Simon
    Voss, Paul L.
    Salvestrini, Jean Paul
    Ougazzaden, Abdallah
    ACS OMEGA, 2022, 7 (01): : 804 - 809