Evaluation of B10Plus+* Proportional Detectors for Neutron Coincidence Counting

被引:0
|
作者
Yoon, S. [1 ]
Beddingfield, D. H. [1 ]
机构
[1] IAEA, Dept Safeguards, Vienna, Austria
来源
2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA) | 2015年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the BRIPlus+w proportional counter. The detector design is intended to serve as a costeffective alternative to traditional He-3 proportional counters in a variety of applications. The detector is a hybrid design B-10-lined tube optimized with the addition of a small quantity of He-3 gas to improve the detector performance and efficiency. As a demonstration of the BIOPlus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B10Plus+ proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] ABSOLUTE NEUTRON COUNTING BASED ON B-10 ALPHA-GAMMA-COINCIDENCE METHODS
    GILLIAM, DM
    GREENE, GL
    LAMAZE, GP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (01): : 220 - 222
  • [2] A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors
    Gamage, Kelum A. A.
    Joyce, Malcolm J.
    Cave, Frank D.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [3] 10B multi-grid proportional gas counters for large area thermal neutron detectors
    Andersen, K.
    Bigault, T.
    Birch, J.
    Buffet, J. C.
    Correa, J.
    Hall-Wilton, R.
    Hultman, L.
    Hoglund, C.
    Guerard, B.
    Jensen, J.
    Khaplanov, A.
    Kirstein, O.
    Piscitelli, F.
    Van Esch, P.
    Vettier, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 720 : 116 - 121
  • [4] Fast neutron dose evaluation using CR39 by coincidence counting process
    Vilela, Eudice
    Brandao, J. O. C.
    Santos, J. A. L.
    de Freitas, F. F.
    NATURAL RADIATION ENVIRONMENT, 2008, 1034 : 509 - 512
  • [5] B-10-Based Macrostructured Cathode for Neutron Detectors
    Kolesnikov, Alexander G.
    Kurilkin, Aleksey K.
    Bodnarchuk, Viktor I.
    Ovodov, Alexander S.
    Gafurov, Marat R.
    COATINGS, 2025, 15 (02):
  • [6] Organic scintillators containing 10B for neutron detectors
    Kamaya, E
    Matsumoto, F
    Kondo, Y
    Chujo, Y
    Katagiri, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 329 - 331
  • [7] Neutron Detectors Based on 10B-Containing Nanomaterials
    Chkhartishvili, Levan
    Tsagareishvili, Otar
    Tavadze, George
    NUCLEAR RADIATION NANOSENSORS AND NANOSENSORY SYSTEMS, 2016, : 187 - 196
  • [8] Experimental evaluation of a boron-lined parallel plate proportional counter for use in nuclear safeguards coincidence counting
    Henzlova, D.
    Evans, L. G.
    Menlove, H. O.
    Swinhoe, M. T.
    Marlow, J. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 697 : 114 - 121
  • [9] Evaluation of ZnS-family phosphors for neutron detectors using photon counting method
    Kubota, N
    Katagiri, M
    Kamijo, K
    Nanto, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 321 - 324
  • [10] GAMMA- AND FAST NEUTRON-SENSITIVITY OF 10B-BASED NEUTRON DETECTORS AT ESS
    Messi, F.
    Piscitelli, F.
    Mauri, G.
    Anastasopoulos, M.
    Fissum, K.
    Hall-Wilton, R.
    Hoglund, C.
    Kanari, K.
    Karnickis, E.
    Khaplanov, A.
    Pazmandi, P.
    Perrey, H.
    Robinson, L.
    Scherzinger, J.
    Varga, D.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,