Intravascular foreign bodies: danger of unretrieved fragmented medical devices

被引:25
|
作者
Tateishi, Minori [1 ]
Tomizawa, Yasuko [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, Tokyo 1628666, Japan
关键词
Foreign bodies; Medical device; Complication; Retrieval; MRI; SIROLIMUS-ELUTING STENT; LUMINAL CORONARY ANGIOPLASTY; PINCH-OFF SYNDROME; FEMORAL-ARTERY DISEASE; ATRIAL SEPTAL-DEFECT; PERCUTANEOUS RETRIEVAL; GUIDE-WIRE; PULMONARY-ARTERY; STRUT FRACTURE; SURGICAL REMOVAL;
D O I
10.1007/s10047-009-0447-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A warning on the danger of unretrieved device fragments and recommendations to mitigate the danger were issued by the Food and Drug Administration in January 2008. The causes of intravascular foreign bodies are classified into three main categories: improper manipulation and usage, device defects, and others, such as patient and anatomical factors. Device failure after long-term use is rarely predicted at the time of approval, since device abnormality is rarely experienced in animal studies and clinical trials conducted during development of the device. Stent fracture due to metal fatigue is one example. Complex complications could occur from simultaneous use of two or more devices with diverse characteristics. The success rate of percutaneous retrieval of intravascular foreign bodies has improved with the advances in commercially available devices. However, the procedure is not always successful and sometimes surgical removal becomes necessary. Appropriate device selection and acquisition of experience in using the device are important. When an intravascular foreign body cannot be retrieved, the risk of complication could be high. Magnetic resonance imaging examination sometimes causes adverse events, including burns due to the heat generated by metal movement. Such information should be correctly recorded. Furthermore, it is necessary to provide patients with adequate information about the characteristics of implanted devices and unretrieved fragments. We reviewed the literature on unretrieved medical device fragments and include articles that describe the Japanese experience.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 50 条
  • [31] Retrieval of intravascular iatrogenic foreign bodies using a nonsurgical technique
    Martin, L
    Strahan, K
    Murphy, G
    POSTGRADUATE MEDICAL JOURNAL, 1997, 73 (864) : 664 - 666
  • [32] Gastrointestinal devices: common and uncommon foreign bodies
    Shen, Luyao
    Aslan, Emre
    Cao, Jennie J.
    Shen, Jody
    Tse, Justin R.
    ABDOMINAL RADIOLOGY, 2024, 49 (08) : 2782 - 2796
  • [33] Secondarily accelerated foreign bodies as a source of danger from airbag deployment
    Rother, T.
    Riechelmann, H.
    Gronau, S.
    HNO, 2006, 54 (12) : 967 - 970
  • [34] Colorectal foreign bodies: a complex medical problem
    Aguirre, PAA
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2001, 93 (10) : 629 - 630
  • [35] Foreign bodies in the heart: Surgical or medical therapy?
    Dato, GMA
    Aidala, E
    Zattera, GF
    ANNALS OF THORACIC SURGERY, 1999, 68 (01): : 291 - 292
  • [36] Foreign bodies in the rectum (In the eyes of a medical court )
    Trojan, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1927, 53 : 1781 - 1781
  • [37] Search and Rescue: A Case Report and Discussion of Iatrogenic Intravascular Foreign Bodies
    Kass, Jonathan
    Sherkat, Amir
    Nahum, Elmer
    Hartman, Matthew
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2021, 50 (02) : 268 - 273
  • [38] Transesophageal Echocardiography Use in Diagnosis and Management of Embolized Intravascular Foreign Bodies
    Herbert, James Taylor
    Kertai, Miklos David
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 22 (01) : 100 - 103
  • [39] Danger to public health: Medical devices, toxicity, virus and fraud
    Kierkegaard, Sylvia
    Kierkegaard, Patrick
    COMPUTER LAW & SECURITY REVIEW, 2013, 29 (01) : 13 - 27
  • [40] EXTRACTION OF INTRAVASCULAR FOREIGN-BODIES BY CATHETERISM WAYS (TECHNIQUES, RESULTS AND INDICATIONS)
    PICARD, L
    SIGIEL, M
    ROLAND, J
    ANESTHESIE ANALGESIE REANIMATION, 1976, 33 (06): : 1011 - 1019