Detection and modeling of the cardiac magnetic field using high-Tc SQUID gradiometers

被引:0
|
作者
Yang, HC [1 ]
Hung, SY
Liao, SH
Hsu, SJ
Wang, SY
Chen, JC
Chen, MJ
Wu, CH
Horng, HE
Yang, SY
Jeng, JT
机构
[1] Natl Taiwan Univ, Dept Phys, Taipei 106, Taiwan
[2] Natl Taiwan Normal Univ, Dept Phys, Taipei 116, Taiwan
[3] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 116, Taiwan
[4] Natl Taipei Univ Technol, Dept Mech Engn, Taipei 106, Taiwan
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Single channel MCG systems were used to probe the magnetic field signal from the heart activity in an unshielded or magnetically moderate shielded environment. Using the FFT of magnetometers with the Harming window overlapped, we optimized the parameters required for the subtraction circuit to minimize the environmental noises in the frequency ranges of interest. Using the optimized parameters, low pass and notch filters, we reduced the environmental noise level much lower than the signal of the heart activity. Hence, we can perform MCG measurements in a magnetically unshielded environment or moderate shielded environment. It was found that a signal to noise ratio of 17 for four-vector gradiometer and 8 for 1(st) order gradiometer were achieved in a moderate shielded environment. The four-vector gradiometer further improve the two times the sensitivity inside the moderate shielded room compared with that of the 1(st) order gradiometer. To solve the inverse problem we simulated the magnetic field data with the current-dipoles model and obtained the optimized moving orbits of current dipoles. The current density mapping of the circulating current was derived. A comparison between the measured data and simulated results is given.
引用
收藏
页码:508 / 519
页数:12
相关论文
共 50 条
  • [41] Imaging high-frequency magnetic and electric fields using a high-Tc SQUID microscope
    Chatraphorn, S
    Fleet, EF
    Wellstood, FC
    Black, RC
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4381 - 4384
  • [42] Imaging high-frequency magnetic and electric fields using a high-Tc SQUID microscope
    Univ of Maryland, College Park, United States
    IEEE Trans Appl Supercond, 2 III (4381-4384):
  • [43] Detection of moving fine iron particles by high-Tc SQUID
    Nagaishi, T.
    Toyoda, H.
    Kugai, H.
    Itozaki, H.
    Applied Superconductivity, 1998, 6 (07): : 303 - 308
  • [44] Detection of moving fine iron particles by high-Tc SQUID
    Nagaishi, T
    Toyoda, H
    Kugai, H
    Itozaki, H
    APPLIED SUPERCONDUCTIVITY, 1998, 6 (7-9) : 303 - 308
  • [45] High-Tc SQUID detection system for contaminants in food and drug
    Tanaka, S
    Hotta, N
    Kudo, S
    Tsuboi, S
    Hatsukade, Y
    Nagaishi, T
    Nishi, K
    Ota, H
    Suzuki, S
    CHINESE JOURNAL OF PHYSICS, 2004, 42 (04) : 526 - 533
  • [46] First derivative high-Tc SQUID gradiometers with narrow structure from single layer YBCO thin film
    Matsuda, M
    Matsuura, T
    Kato, K
    Oyama, H
    Hayashi, A
    Hirano, S
    Kuriki, S
    IEICE TRANSACTIONS ON ELECTRONICS, 2002, E85C (03) : 677 - 680
  • [47] Magnetocardiography with high-TC gradiometers working in unshielded environments
    Seidel, P
    Weidl, R
    Brabetz, S
    Schmidl, F
    Nowak, H
    Leder, U
    APPLIED SUPERCONDUCTIVITY, 1998, 6 (7-9) : 309 - 316
  • [48] Development of a high-Tc SQUID cryo-system for the measurement of a remanent magnetic field of rock
    Tanaka, S
    Shimizu, R
    Saito, Y
    Shin, K
    IEICE TRANSACTIONS ON ELECTRONICS, 2000, E83C (01) : 44 - 48
  • [49] Effect of a static magnetic field on a slotted high-Tc SQUID magnetometer without a flux dam
    Yokosawa, K
    Oyama, H
    Kuriki, S
    Suzuki, D
    Tsukada, K
    Matsuda, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 1335 - 1338
  • [50] SQUID gradiometers for a fundamental study of underwater magnetic detection
    Hirota, M
    Nanaura, K
    Teranishi, Y
    Kishigami, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 2327 - 2330