Simultaneous determination of t,t-muconic, S-phenylmercapturic and S-benzylmercapturic acids in urine by a rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry method

被引:39
|
作者
Barbieri, A
Sabatini, L
Accorsi, A
Roda, A
Violante, FS
机构
[1] Univ Bologna, Safety Hyg & Occupat Med Serv, I-40138 Bologna, Italy
[2] Univ Bologna, Policlin St Orsola Malpighi, Occupat Med Unit, I-40138 Bologna, Italy
[3] Univ Bologna, Dept Pharmaceut Sci, I-40126 Bologna, Italy
关键词
D O I
10.1002/rcm.1580
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a rapid and sensitive high-performance liquid chromatography/electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for simultaneous determination of the most relevant metabolites of benzene and toluene, t,t-muconic acid (t,t-MA), S-phenylmercapturic acid (S-PMA), and S-benzylmercapturic acid (S-BMA). Urine samples were purified before analysis by solid-phase microextraction (SPE) on SAX cartridges with 50mg sorbent mass. The developed method fulfils all the standard requirements of precision and accuracy. Calibration curves were linear within the concentration range of the standards (0-80 mug/L-urine for t,t-MA, and 0-25 mug/L-urine for S-PMA and S-BMA), and had correlation coefficients greater than or equal to0.997. Limits of detection were 6.0 mug/L for t,t-MA, 0.3 mug/L for S-PMA, and 0.4 mug/L for S-BMA. The method was used to determine t,t-MA, S-PMA and S-BMA levels in urine of 31 gasoline-station workers, with personal monitoring data obtained from radial symmetry passive diffusive samplers. In the context of mean work-shift exposures of 75.9 mug/m(3) (range 9.4-220.2) for benzene and 331.9 mug/m(3) (78.2-932.1) for toluene, metabolite concentrations in end-of-shift urine samples ranged from 23.5-275.3 mug/g(creatinine) for t,t-MA, non-detectable to 0-9mug/g(creatinine), for S-PMA, and 3.8-74.8mug/g(creatinine) for S-BMA. No significant correlation was found between the environmental concentrations and urinary metabolites (p > 0.05 for all cases); the ratios of benzene metabolites could be influenced by exposure levels and co-exposure to xylenes and toluene. The high throughput of this procedure should facilitate exploration of the metabolic effects of benzene-related co-exposure to toluene and alkylbenzenes in large populations of subjects exposed to gasoline. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1983 / 1988
页数:6
相关论文
共 50 条
  • [41] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma
    Wiesner, JL
    de Jager, AD
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 115 - 121
  • [42] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of stavudine in human plasma
    Wiesner, JL
    Sutherland, FCW
    Smit, MJ
    van Essen, GH
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 129 - 134
  • [43] Simultaneous determination of low levels of methotrexate and cyclophosphamide in human urine by micro liquid chromatography/electrospray ionization tandem mass spectrometry
    Barbieri, A
    Sabatini, L
    Indiveri, P
    Bonfiglioli, R
    Lodi, V
    Violante, FS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1889 - 1893
  • [44] Validation of a highly sensitive method for the determination of neonicotinoid insecticides residues in honeybees by liquid chromatography with electrospray tandem mass spectrometry
    Martel, Anne-Claire
    Lair, Cosette
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (10) : 978 - 988
  • [45] Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma
    Chen, XY
    Huang, J
    Kong, Z
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 263 - 269
  • [46] Simultaneous Determination of 12 Toxic Alkaloids in Urine and Gastric Juice Using Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Zhang Chun-Hua
    Wu Hui-Qin
    Huang Xiao-Lan
    Zhu Zhi-Xin
    Huang Fang
    Lin Xiao-Shan
    Luo Hui-Tai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) : 862 - 869
  • [47] Selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of alfuzosin in human plasma
    Wiesner, JL
    Sutherland, FCW
    van Essen, GH
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 361 - 368
  • [48] A rapid and sensitive method for determination of sorafenib in human plasma using a liquid chromatography/tandem mass spectrometry assay
    Zhao, Ming
    Rudek, Michelle A.
    He, Ping
    Hafner, Frank-Thorsten
    Radtke, Martin
    Wright, John J.
    Smith, B. Douglas
    Messersmith, Wells A.
    Hidalgo, Manuel
    Baker, Sharyn D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 1 - 7
  • [49] A Rapid and Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Olopatadine Concentration in Human Plasma
    Zhu, Ping
    Wen, Yu-Guan
    Fan, Xiao-Ping
    Zhou, Zhi-Ling
    Fan, Rui-Xin
    Chen, Ji-Mei
    Huang, Ke-li
    Zhu, Xiao-lan
    Chen, Yan-Fang
    Zhuang, Jian
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (02) : 113 - 118
  • [50] A Sensitive and Rapid Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Metoclopramide Hydrochloride in Human Plasma
    Ramesh, N.
    Shabaraya, Ramakrishna
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (03): : 527 - 534