A GPU OpenCL based cross-platform Monte Carlo dose calculation engine (goMC)

被引:28
|
作者
Tian, Zhen [1 ]
Shi, Feng [1 ]
Folkerts, Michael [1 ]
Qin, Nan [1 ]
Jiang, Steve B. [1 ]
Jia, Xun [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 19期
关键词
Monte Carlo dose calculation; GPU; OpenCL; DEFORMABLE IMAGE REGISTRATION; BEAM CT RECONSTRUCTION; IMPLEMENTATION; SIMULATIONS; PHOTON; ALGORITHM; TRANSPORT; CODE;
D O I
10.1088/0031-9155/60/19/7419
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo (MC) simulation has been recognized as the most accurate dose calculation method for radiotherapy. However, the extremely long computation time impedes its clinical application. Recently, a lot of effort has been made to realize fast MC dose calculation on graphic processing units (GPUs). However, most of the GPU-based MC dose engines have been developed under NVidia's CUDA environment. This limits the code portability to other platforms, hindering the introduction of GPU-based MC simulations to clinical practice. The objective of this paper is to develop a GPU OpenCL based cross-platform MC dose engine named goMC with coupled photon-electron simulation for external photon and electron radiotherapy in the MeV energy range. Compared to our previously developed GPU-based MC code named gDPM (Jia et al 2012 Phys. Med. Biol. 57 7783-97), goMC has two major differences. First, it was developed under the OpenCL environment for high code portability and hence could be run not only on different GPU cards but also on CPU platforms. Second, we adopted the electron transport model used in EGSnrc MC package and PENELOPE's random hinge method in our new dose engine, instead of the dose planning method employed in gDPM. Dose distributions were calculated for a 15 MeV electron beam and a 6 MV photon beam in a homogenous water phantom, a water-bone-lung-water slab phantom and a half-slab phantom. Satisfactory agreement between the two MC dose engines goMC and gDPM was observed in all cases. The average dose differences in the regions that received a dose higher than 10% of the maximum dose were 0.48-0.53% for the electron beam cases and 0.15-0.17% for the photon beam cases. In terms of efficiency, goMC was similar to 4-16% slower than gDPM when running on the same NVidia TITAN card for all the cases we tested, due to both the different electron transport models and the different development environments. The code portability of our new dose engine goMC was validated by successfully running it on a variety of different computing devices including an NVidia GPU card, two AMD GPU cards and an Intel CPU processor. Computational efficiency among these platforms was compared.
引用
收藏
页码:7419 / 7435
页数:17
相关论文
共 50 条
  • [41] Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport
    Jia, Xun
    Gu, Xuejun
    Sempau, Josep
    Choi, Dongju
    Majumdar, Amitava
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11): : 3077 - 3086
  • [42] Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system
    Paudel, Moti R.
    Kim, Anthony
    Sarfehnia, Arman
    Ahmad, Sayed B.
    Beachey, David J.
    Sahgal, Arjun
    Keller, Brian M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 230 - 241
  • [43] A GPU-Accelerated Monte Carlo Dose Computation Engine for Precision Small Animal Radiotherapy
    Liu, Z.
    Yang, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E494 - E494
  • [44] Research on GPU Acceleration for Monte Carlo Criticality Calculation
    Xu Qi
    Yu Ganglin
    Wang Kan
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [45] A GPU-Accelerated Monte-Carlo Dose Calculation Platform and Its Application Toward Validating a View Ray Beam Model
    Wang, Y.
    Mazur, T.
    Green, O.
    Hu, Y.
    Wooten, H.
    Yang, D.
    Zhao, T.
    Mutic, S.
    Li, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3339 - 3339
  • [46] Update 2.70 to "GOMC: GPU Optimized Monte Carlo for the simulation of phase equilibria and physical properties of complex fluids"
    Nejahi, Younes
    Barhaghi, Mohammad Soroush
    Schwing, Gregory
    Schwiebert, Loren
    Potoff, Jeffrey
    SOFTWAREX, 2021, 13
  • [47] Monte Carlo Simulation Based Dose Calculation in Magnetic Field
    Qi, M.
    Zhou, L.
    Li, Y.
    Song, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E558 - E558
  • [48] Fast Monte Carlo dose calculation based on deep learning
    Fu, Jiaqi
    Bai, Jingfeng
    Liu, Yanfang
    Ni, Cheng
    2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 721 - 726
  • [49] Verification and Validation of GPU-based TomoTherapy Dose Calculation Engine
    Chen, Q.
    Chen, M.
    Henderson, D.
    Chen, Y.
    Olivera, G.
    Lu, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S732 - S733
  • [50] Monte carlo calculation of internal dose based on SPECT/CT
    Ahunbay, E.
    Steinfelds, E.
    Hellman, R.
    Peng, C.
    Li, X.
    MEDICAL PHYSICS, 2007, 34 (06) : 2568 - 2568